High-enthalpy hot-shot wind tunnel with combined heating and stabilization of parameters

被引:16
|
作者
Maslov, A. A. [1 ]
Shumsky, V. V. [1 ]
Yaroslavtsev, M. I. [1 ]
机构
[1] RAS, Khristianovich Inst Theoret & Appl Mech, SB, Novosibirsk, Russia
基金
俄罗斯基础研究基金会;
关键词
high-enthalpy hot-shot wind tunnel; shock tube; settling chamber; test gas; stabilization of parameters; pressure multiplier; electric arc; chemical heating; adiabatic compression; delay of diaphragm breakdown;
D O I
10.1134/S0869864313050011
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
In the present paper, we consider instrumentation and the experimental procedure for conducting tests in a highenthalpy short-duration wind-tunnel facility, namely, a hypersonic hot-shot wind tunnel. We consider operation of the hot-shot wind tunnel with the test gas (TG) parameters kept constant during the regime and also operation of the tunnel as a traditional shock tube with a decay of the TG parameters that occurs as the TG leaves a constant-volume settling chamber. Stabilization of the TG parameters is achieved by using a pressure multiplier installed coaxially with the settling chamber, the configuration presenting a linear arrangement of the two components. Unloading of pressure multiplier dynamic component is achieved by using an equalizer whose piston moves in the opposite direction to the multiplier piston system. Several modes of wind tunnel operation with various combinations of different TG heating methods (electric arc, chemical energy, adiabatic compression, or heating in an external with respect to the settling chamber heat source) are possible. The design of a device responsible for diaphragm breakdown delay is considered. The design and dimensions of the wind tunnel provide for its normal operation under the following conditions: range of Mach numbers M = 4-20, range of settling-chamber temperatures T (ch1) = 600-4000 K, and settling-chamber pressure p (ch1) up to 200 MPa (in operation with a double settling chamber, the stagnation pressure p (0n) = p (ch2) can be varied from 1 to 200 MPa). The settling chamber volume (80-100 dm(3)) is sufficiently large, allowing obtaining a 1-m diameter hypersonic stream in the test section during similar to 100 ms (in combination with a second settling chamber).
引用
收藏
页码:527 / 538
页数:12
相关论文
共 50 条
  • [11] Advances in critical technologies for hypersonic and high-enthalpy wind tunnel
    JIANG, Zonglin
    HU, Zongmin
    WANG, Yunpeng
    HAN, Guilai
    CHINESE JOURNAL OF AERONAUTICS, 2020, 33 (12) : 3027 - 3038
  • [12] Advances in critical technologies for hypersonic and high-enthalpy wind tunnel
    Zonglin JIANG
    Zongmin HU
    Yunpeng WANG
    Guilai HAN
    Chinese Journal of Aeronautics, 2020, 33 (12) : 3027 - 3038
  • [13] Advances in critical technologies for hypersonic and high-enthalpy wind tunnel
    Zonglin JIANG
    Zongmin HU
    Yunpeng WANG
    Guilai HAN
    Chinese Journal of Aeronautics , 2020, (12) : 3027 - 3038
  • [14] Composition of the Test Gas in the Test Section of a High-Enthalpy Wind Tunnel
    Shumskii, V. V.
    Yaroslavtsev, M. I.
    COMBUSTION EXPLOSION AND SHOCK WAVES, 2012, 48 (01) : 24 - 32
  • [15] Backscattering measurements of plasma coated target in high-enthalpy wind tunnel
    Jin Ming
    Wei Xiao
    Wu Yang
    Zhang Yu-Huai
    Yu Xi-Long
    ACTA PHYSICA SINICA, 2015, 64 (20)
  • [16] Measurement and diagnosis of the wake electron density in high-enthalpy wind tunnel
    Liao, Guang
    Lin, Zhen-Bin
    Guo, Da-Hua
    Lin, Jian-Min
    Shiyan Liuti Lixue/Journal of Experiments in Fluid Mechanics, 2010, 24 (05): : 79 - 82
  • [17] Composition of the test gas in the test section of a high-enthalpy wind tunnel
    V. V. Shumskii
    M. I. Yaroslavtsev
    Combustion, Explosion, and Shock Waves, 2012, 48 : 24 - 32
  • [18] PLASMA SHEATHS OF MODELS IN HOT-SHOT WIND TUNNELS
    DOREY, J
    COMPARD, D
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1967, AES3 (02) : 259 - &
  • [19] Development of pulsed arc heater for small hypersonic high-enthalpy wind tunnel
    Biagioni, Leonardo
    Scortecci, Fabrizio
    Paganucci, Fabrizio
    Journal of Spacecraft and Rockets, 36 (05): : 704 - 710
  • [20] Development of pulsed arc heater for small hypersonic high-enthalpy wind tunnel
    Biagioni, L
    Scortecci, F
    Paganucci, F
    JOURNAL OF SPACECRAFT AND ROCKETS, 1999, 36 (05) : 704 - 710