Selective and Highly Sensitive Voltammetric Determination of Citalopram with Glassy Carbon Electrode

被引:11
|
作者
Madej, Maria [1 ]
Kochana, Jolanta [1 ]
Bas, Boguslaw [2 ]
机构
[1] Jagiellonian Univ, Fac Chem, Dept Analyt Chem, PL-30387 Krakow, Poland
[2] AGH Univ Sci & Technol, Fac Mat & Ceram, Dept Analyt Chem, PL-30059 Krakow, Poland
关键词
MUNICIPAL WASTE-WATER; LIQUID-CHROMATOGRAPHY; ELECTROCHEMICAL OXIDATION; HUMAN PLASMA; MASS-SPECTROMETRY; NATIONAL RECONNAISSANCE; STRIPPING VOLTAMMETRY; ANTIDEPRESSANT DRUGS; MESOPOROUS CARBON; TREATMENT PLANTS;
D O I
10.1149/2.1291908jes
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This work proposes a simple and very sensitive method for electrochemical determination of citalopram by differential pulse voltammetry (DPV) using glassy carbon electrode. The cyclic voltammetry measurements proved that citalopram undergoes irreversible, adsorption-controlled, two-electron oxidation process, accompanied by the release of two protons. The influence of different measurement conditions, such as type and pH of supporting electrolyte solution, as well as DPV parameters was investigated. The glassy carbon electrode (GCE) exhibits fast linear response toward citalopram oxidation in concentration ranges of 0.05-10 mu mol L-1 and 10-115 mu mol L-1 with detection limit (LOD) of 0.036 mu mol L-1. The proposed method provides low detection limit, high accuracy and precision with good selectivity in comparison to previously reported methods. The applicability of developed method was tested by determination of citalopram in pharmaceuticals and spiked tap, river and waste water samples. (C) 2019 The Electrochemical Society.
引用
收藏
页码:H359 / H369
页数:11
相关论文
共 50 条
  • [21] Sensitive Voltammetric Determination of Baicalein at Thermally Reduced Graphene Oxide Modified Glassy Carbon Electrode
    Zhang, Dongdong
    Zhang, Yanmin
    He, Langchong
    ELECTROANALYSIS, 2013, 25 (09) : 2136 - 2144
  • [22] Study of the voltammetric behavior of jatrorrhizine and its sensitive determination at electrochemical pretreatment glassy carbon electrode
    Ye, Zhuo
    Li, Yinfeng
    Wen, Jianguo
    Li, Kunjing
    Ye, Baoxian
    TALANTA, 2014, 126 : 38 - 45
  • [23] Voltammetric Determination of Clenbuterol on Electrochemically Activated Glassy Carbon Electrode
    Lee, Sohee
    Piao, Yuanzhe
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2014, 17 (04): : 216 - 221
  • [24] VOLTAMMETRIC DETERMINATION OF PHENYLBUTAZONE AND OXYPHENBUTAZONE AT A GLASSY-CARBON ELECTRODE
    CHAN, HK
    FOGG, AG
    ANALYTICA CHIMICA ACTA, 1979, 109 (02) : 341 - 349
  • [25] Voltammetric determination of 5-methylcytosine at glassy carbon electrode
    Mendes, Carlos H. S.
    Silva, Maycom W. F.
    Oliveira, Severino Carlos B.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 895
  • [26] Voltammetric determination of chloramphenicol at electrochemically pretreated glassy carbon electrode
    Alemu, Hailemichael
    Hlalele, Lebohang
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2007, 21 (01) : 1 - 12
  • [27] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [28] Voltammetric determination of necrodil sodium using glassy carbon electrode
    Rosa, TF
    Saczk, AA
    Zanoni, MVB
    Stradiotto, NR
    ECLETICA QUIMICA, 2003, 28 (02): : 63 - 68
  • [29] VOLTAMMETRIC DETERMINATION OF RUPATADINE AT GRAPHENE MODIFIED GLASSY CARBON ELECTRODE
    Devnani, H.
    Singh, P.
    Saxena, S.
    Satsangee, S. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2014, 5 (11):
  • [30] VOLTAMMETRIC DETERMINATION OF HYDRAZINE ON GLASSY CARBON ELECTRODE IN AQUEOUS SOLUTIONS
    Kira, Alekseenko V.
    Valentina, Batalova N.
    Gennady, Mokrousov M.
    Daria, Martynova N.
    TOMSK STATE UNIVERSITY JOURNAL, 2013, (376): : 192 - +