CFRP strengthening for punching shear of interior slab-column connections

被引:33
|
作者
Sharaf, Mohamed H.
Soudki, Khaled A. [1 ]
Van Dusen, Michael
机构
[1] Univ Waterloo, Dept Civil Engn, Waterloo, ON N2L 3G1, Canada
[2] Halsall Associates Ltd, Toronto, ON M4P 1E4, Canada
关键词
Concrete slabs; Concrete; reinforced; Fiber reinforced polymers; Reinforcement; Shear;
D O I
10.1061/(ASCE)1090-0268(2006)10:5(410)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental investigation studying the effect of retrofitting interior slab-column connections against punching shear failure with externally bonded carbon fiber reinforced polymer (CFRP) strips. Six full-scale, 2000 mm-square x 150-mm-thick slab specimens were constructed. The effect of varying the CFRP strengthening amount and configuration on the load-carrying capacity of the slab specimens was investigated. Specimens were supported along their edges and tested to failure. Strengthened slabs showed an increase in stiffness between 29 and 60% and in punching capacity between 6 and 16% with respect to the control unstrengthened slab. An analytical model was refined to predict the punching shear capacity of the specimens strengthened with CFRP strips. The model takes into account both the configuration and amount of CFRP strips. The proposed model shows good agreement with the experimental results.
引用
收藏
页码:410 / 418
页数:9
相关论文
共 50 条
  • [41] New shear strengthening technique for concrete slab-column connections
    El-Salakawy, EF
    Polak, MA
    Soudki, KA
    ACI STRUCTURAL JOURNAL, 2003, 100 (03) : 297 - 304
  • [42] SEISMIC RESPONSE OF INTERIOR SLAB-COLUMN CONNECTIONS WITH SHEAR CAPITALS
    WEY, EH
    DURRANI, AJ
    ACI STRUCTURAL JOURNAL, 1992, 89 (06) : 682 - 691
  • [43] Punching capacity of slab-column edge connections
    College of Civil Engineering, Hunan Univ., Changsha 410082, China
    Hunan Daxue Xuebao, 2007, 1 (19-23):
  • [44] Calculation of punching shear capacity of RC slab-column connections without shear reinforcement
    Xia C.
    Shi Q.
    Wang Z.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2022, 54 (04): : 18 - 24
  • [45] Punching shear strength of reinforced concrete transfer slab-column connections with shear reinforcement
    Kang, Su-Min
    Na, Su-Jeong
    Hwang, Hyeon-Jong
    ENGINEERING STRUCTURES, 2021, 243
  • [46] Investigations on punching behaviour of Slab-Column Edge Connections with and without shear reinforcement
    Hegger, J.
    Ricker, M.
    BAUINGENIEUR, 2007, 82 : 177 - 184
  • [47] Strengthening of slab-column connections against punching shear using FRP materials: state-of-the-art review
    Saleh, Haifa
    Abdouka, Kamiran
    Al-Mahaidi, Riadh
    Kalfat, Robin
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2018, 19 (03) : 188 - 206
  • [48] A design model for punching shear of FRP-reinforced slab-column connections
    Theodorakopoulos, D. D.
    Swamy, R. N.
    CEMENT & CONCRETE COMPOSITES, 2008, 30 (06): : 544 - 555
  • [49] Punching of slab-column connections strengthened using external steel shear bolts
    Baig, Zafar Iqbal
    Alsayed, Saleh H.
    Abbas, Husain
    MAGAZINE OF CONCRETE RESEARCH, 2016, 68 (02) : 55 - 68
  • [50] Shear strengthening of interior slab-column connections using carbon fiber-reinforced polymer sheets
    Harajli, MH
    Soudki, KA
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (02) : 145 - 153