Influence of sample storage duration on serum protein profiles assessed by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS)

被引:33
|
作者
Gast, Marie-Christine W. [1 ]
van Gils, Carla H. [2 ]
Wessels, Lodewijk F. A. [3 ,4 ]
Harris, Nathan [5 ]
Bonfrer, Johannes M. G. [6 ]
Rutgers, Emiel J. Th. [7 ]
Schellens, Jan H. M. [8 ,9 ]
Beijnen, Jos H. [1 ,9 ]
机构
[1] Netherlands Canc Inst, Slotervaart Hosp, Dept Pharm & Pharmacol, NL-1006 BK Amsterdam, Netherlands
[2] Univ Med Ctr Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[3] Netherlands Canc Inst, Dept Mol Biol, NL-1006 BK Amsterdam, Netherlands
[4] Tech Univ Delft, Fac EEMCS, Delft, Netherlands
[5] Vermillion Inc, Fremont, CA USA
[6] Antoni Van Leeuwenhoek Hosp, Gen Clin Lab, Amsterdam, Netherlands
[7] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Surg, Amsterdam, Netherlands
[8] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Clin Oncol, Div Med Oncol, Amsterdam, Netherlands
[9] Univ Utrecht, Fac Sci, Dept Pharmaceut Sci, Div Biomed Anal, Utrecht, Netherlands
关键词
pre-analytical parameters; proteomics; serum protein profiling; storage duration; surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS); DESORPTION-IONIZATION-TIME; CHRONIC HEPATITIS-C; BREAST-CANCER; HEPATOCELLULAR-CARCINOMA; COMPLEMENT COMPONENT; PROTEOMIC ANALYSIS; COLORECTAL-CANCER; C3A ANAPHYLATOXIN; ADJUVANT CHEMOTHERAPY; PEPTIDOME PATTERNS;
D O I
10.1515/CCLM.2009.151
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Issues have been raised concerning the robustness and validity of alleged serum markers discovered by surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF MS). Pre-analytical variables have been shown to exert a profound effect on protein profiles, irrespective of true biological variation. However, little is known about the possible effects of sample storage duration on protein profiles. We, therefore, aimed to investigate the effects of extended storage duration on the serum protein profile. Methods: Archival sera from 140 breast cancer patients, stored at -30 degrees C for 1-11 years, were profiled by SELDI-TOF MS using immobilised metal affinity capture (IMAC) arrays, a condition applied in the majority of breast cancer biomarker discovery studies. Results: Fourteen peak clusters, structurally identified as C3a des-arginine anaphylatoxin and multiple fragments of albumin and fibrinogen, were found to be significantly associated with sample storage duration by five distinct patterns. These proteins have been described previously as potential cancer markers, rendering them specific to both disease and sample handling issues. Conclusions: To prevent experimental variation being interpreted erroneously as disease associated variation, assessment of potential confounding pre-analytical parameters is a pre-requisite in biomarker discovery and validation studies. In addition, with respect to the different (non-)linear patterns observed in the current study, simply performing linear corrections to account for sample storage duration will not necessarily suffice. Clin Chem Lab Med 2009;47:694-705.
引用
收藏
页码:694 / 705
页数:12
相关论文
共 50 条
  • [31] Use of surface enhanced laser desorption/ionization-time of flight mass spectrometry (SELDI-TOF MS) to study protein expression in a rat model of cocaine withdrawal
    Geng, Tao
    Seitz, Patricia K.
    Thomas, Mary L.
    Xu, Bo
    Soman, Kizhake V.
    Kurosky, Alexander
    Luxon, Bruce A.
    Cunningham, Kathryn A.
    JOURNAL OF NEUROSCIENCE METHODS, 2006, 158 (01) : 1 - 12
  • [32] Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry: serum protein profiling in seminoma patients
    Romy Strenziok
    Stefan Hinz
    Christian Wolf
    Tim Conrad
    Hans Krause
    Kurt Miller
    Mark Schrader
    World Journal of Urology, 2010, 28 : 193 - 197
  • [33] Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry: serum protein profiling in seminoma patients
    Strenziok, Romy
    Hinz, Stefan
    Wolf, Christian
    Conrad, Tim
    Krause, Hans
    Miller, Kurt
    Schrader, Mark
    WORLD JOURNAL OF UROLOGY, 2010, 28 (02) : 193 - 197
  • [34] Identification of protein biomarkers in Dupuytren's contracture using surface enhanced laser desorption ionization time-of-flight mass spectrometry (SELDI-TOF-MS)
    O'Gorman, David
    Howard, Jeffrey C.
    Varallo, Vincenzo M.
    Cadieux, Peter
    Bowley, Erin
    McLean, Kris
    Pak, Brian J.
    Gan, Bing Siang
    CLINICAL AND INVESTIGATIVE MEDICINE, 2006, 29 (03): : 136 - 145
  • [35] Age-dependent increase in thiol conjugated forms of transthyretin (TTR) in the elderly: quantitative analyses by the surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF MS) protein chip system
    Kawahara, S.
    Ueda, M.
    Miyazaki, A.
    Yuki, U.
    Shono, M.
    Horibata, Y.
    Jono, H.
    Obayashi, K.
    Ikeda, K.
    Tanase, S.
    Ando, Y.
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2011, 18 : 14 - 16
  • [36] Different protein profile in amniotic fluid with nervous system malformations by surface-enhanced laser desorption-ionization/time-of-flight mass spectrometry (SELDI-TOF-MS) technology
    Ma, Zhe
    Liu, Cun
    Deng, Biping
    Dong, Shaogang
    Tao, Guowei
    Zhan, Xinfeng
    Wang, Chuner
    Liu, ShaoPing
    Qu, Xun
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2010, 36 (06) : 1195 - 1203
  • [37] Surfaced-enhanced laser desorption/ionization time-of-flight (SELDI-TOF) differentiation of serum protein profiles of BRCA-1 and sporadic breast cancer
    Becker, S
    Cazares, LH
    Watson, P
    Lynch, H
    Semmes, OJ
    Drake, RR
    Laronga, C
    ANNALS OF SURGICAL ONCOLOGY, 2004, 11 (10) : 907 - 914
  • [38] Proteomic profiling of maternal plasma collected longitudinally during pregnancy by surface enhanced laser desorption ionization time of flight mass spectrometry (SELDI-TOF MS)
    Ippolito, Danielle
    Hartenstine, Mike
    Cederholm, Heidi
    Bergmann, Aspen
    Napolitano, Peter
    Celver, Jeremy
    McNutt, Patrick
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 195 (06) : S173 - S173
  • [39] Surfaced-Enhanced Laser Desorption/Ionization Time-of-Flight (SELDI-TOF) Differentiation of Serum Protein Profiles of BRCA-1 and Sporadic Breast Cancer
    Stephen Becker
    Lisa H. Cazares
    Patrice Watson
    Henry Lynch
    O. John Semmes
    Richard R. Drake
    Christine Laronga
    Annals of Surgical Oncology, 2004, 11 : 907 - 914
  • [40] Influence of variations in sample handling on SELDI-TOF MS serum protein profiles for colorectal cancer
    Engwegen, Judith Y. M. N.
    Alberts, Marieke
    Knol, Jaco C.
    Jimenez, Connie R.
    Depla, Annekatrien C. T. M.
    Tuynman, Henriette
    van Heukelem, Henk A.
    Snel, Pleun
    Smits, Marianne E.
    Cats, Annemieke
    Schellens, Jan H. M.
    Beijnen, Jos H.
    PROTEOMICS CLINICAL APPLICATIONS, 2008, 2 (06) : 936 - 945