An Improved Design of Current Controller for LCL-Type Grid-Connected Converter to Reduce Negative Effect of PLL in Weak Grid

被引:150
|
作者
Zhou, Shiying [1 ]
Zou, Xudong [1 ]
Zhu, Donghai [1 ]
Tong, Li [2 ]
Zhao, Yingying [3 ]
Kang, Yong [1 ]
Yuan, Xiaoming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Zhejiang Elect Power Corp Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
[3] State Grid Anhui Econ Res Inst, Hefei 230000, Anhui, Peoples R China
关键词
Current controller; grid-connected converter; phase-locked loop (PLL); small-signal impedance model; weak grid; CONTROL STRATEGY; VECTOR CONTROL; VOLTAGE; STABILITY; INVERTER; FILTERS;
D O I
10.1109/JESTPE.2017.2780918
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For three-phase LCL-type grid-connected converter, when it is attached to weak grid, current control interacts with phase-locked loop (PLL) via point of common coupling voltage. Consequently, PLL dynamic might deteriorate grid current control and even result in system instability. However, the conventional design method of current controller neglects the impact of PLL, and therefore, it is hard for the current controller to mitigate the negative effect of PLL. In this paper, an improved design of current controller, i.e., proportional-integral controller and capacitor-current-feedback active damping, is proposed to reduce the negative effect of PLL on current control. First, a small-signal impedance model is developed to analyze the impact of PLL on current control. Then, the effect of current controller parameters on the converter output impedance is analyzed, and a design guideline to improve the current controller parameters is presented. With the improved parameters, in precondition of satisfying system stability margin under both stiff and weak grid, the negative effect of PLL on current control can be effectively mitigated without employing additional control strategies. Furthermore, the current control has a strong robustness against wide-range variation of grid impedance. Finally, the experiment demonstrates the effectiveness of the proposed design method.
引用
收藏
页码:648 / 663
页数:16
相关论文
共 50 条
  • [31] Investigation of the Sideband Effect for the LCL-type Grid-connected Inverter with High LCL Resonance Frequency
    Yang, Dongsheng
    Wang, Xiongfei
    Blaabjerg, Frede
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 5601 - 5606
  • [32] Passivity-Based Design of Repetitive Controller for LCL-Type Grid-Connected Inverters Suitable for Microgrid Applications
    Xie, Chuan
    Liu, Dong
    Li, Kai
    Zou, Jianxiao
    Zhou, Keliang
    M. Guerrero, Josep
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (02) : 2420 - 2431
  • [33] An Improved Active Damping Method with Grid-Side Current Feedback to Maximize Damping Ratio for LCL-Type Grid-Connected Inverter
    Wu, Weibiao
    Peng, Li
    Qi, Yu
    Liu, Qian
    Huang, Zeyi
    Dong, Fangming
    Chen, Manlin
    Wang, Bowen
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 5607 - 5611
  • [34] Robust Voltage Resonance Feedforward Control Strategy for LCL-type Grid-connected Inverters under Weak Grid Condition
    Chang, Xiao
    Lv, Chenxv
    Wang, Qi
    Qin, Wenping
    Zhang, Min
    Liu, Yizhao
    Fan, Rui
    2018 ASIAN CONFERENCE ON ENERGY, POWER AND TRANSPORTATION ELECTRIFICATION (ACEPT), 2018,
  • [35] Research on the stability caused by phase-locked loop for LCL-type grid-connected inverter in weak grid condition
    Wu, Heng
    Ruan, Xinbo
    Yang, Dongsheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2014, 34 (30): : 5259 - 5268
  • [36] Indirect Grid Current Control of LCL Filter based Grid-Connected Converter
    Mukherjee, Subhajyoti
    Shamsi, Pourya
    Ferdowsi, Mehdi
    Kimball, Jonathan
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 3024 - 3031
  • [37] Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method
    Li, Xiaoqiang
    Wu, Xiaojie
    Geng, Yiwen
    Yuan, Xibo
    Xia, Chenyang
    Zhang, Xue
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) : 5247 - 5259
  • [38] Stability analysis for grid-connected LCL-Type inverter with digital control
    Kato T.
    Inoue K.
    Akiyama Y.
    Ohashi K.
    IEEJ Transactions on Industry Applications, 2016, 136 (09) : 615 - 621
  • [39] Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping
    Bao, Chenlei
    Ruan, Xinbo
    Wang, Xuehua
    Li, Weiwei
    Pan, Donghua
    Weng, Kailei
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) : 1239 - 1253
  • [40] An overview on resonance for a multiple LCL-type inverter grid-connected system
    Zheng J.
    Yang G.
    Chen K.
    Zhang H.
    Sun Z.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (21): : 176 - 186