An Improved Design of Current Controller for LCL-Type Grid-Connected Converter to Reduce Negative Effect of PLL in Weak Grid

被引:150
|
作者
Zhou, Shiying [1 ]
Zou, Xudong [1 ]
Zhu, Donghai [1 ]
Tong, Li [2 ]
Zhao, Yingying [3 ]
Kang, Yong [1 ]
Yuan, Xiaoming [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Zhejiang Elect Power Corp Res Inst, Hangzhou 310014, Zhejiang, Peoples R China
[3] State Grid Anhui Econ Res Inst, Hefei 230000, Anhui, Peoples R China
关键词
Current controller; grid-connected converter; phase-locked loop (PLL); small-signal impedance model; weak grid; CONTROL STRATEGY; VECTOR CONTROL; VOLTAGE; STABILITY; INVERTER; FILTERS;
D O I
10.1109/JESTPE.2017.2780918
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For three-phase LCL-type grid-connected converter, when it is attached to weak grid, current control interacts with phase-locked loop (PLL) via point of common coupling voltage. Consequently, PLL dynamic might deteriorate grid current control and even result in system instability. However, the conventional design method of current controller neglects the impact of PLL, and therefore, it is hard for the current controller to mitigate the negative effect of PLL. In this paper, an improved design of current controller, i.e., proportional-integral controller and capacitor-current-feedback active damping, is proposed to reduce the negative effect of PLL on current control. First, a small-signal impedance model is developed to analyze the impact of PLL on current control. Then, the effect of current controller parameters on the converter output impedance is analyzed, and a design guideline to improve the current controller parameters is presented. With the improved parameters, in precondition of satisfying system stability margin under both stiff and weak grid, the negative effect of PLL on current control can be effectively mitigated without employing additional control strategies. Furthermore, the current control has a strong robustness against wide-range variation of grid impedance. Finally, the experiment demonstrates the effectiveness of the proposed design method.
引用
收藏
页码:648 / 663
页数:16
相关论文
共 50 条
  • [1] Improved Design of PLL Controller for LCL-Type Grid-Connected Converter in Weak Grid
    Zhu, Donghai
    Zhou, Shiying
    Zou, Xudong
    Kang, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (05) : 4715 - 4727
  • [2] Stability Analysis of LCL-type Grid-connected Inverter in Weak Grid Systems
    Chen, Xin
    Gong, Chun Yin
    Wang, Hui Zhen
    Cheng, Lin
    INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2012,
  • [3] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137
  • [4] High Robustness Weighted Average Current Control for LCL-type Grid-connected Inverter in a Weak Grid
    Zhu K.
    Sun P.
    Wang L.
    Zhou L.
    Xue T.
    Du X.
    Li Z.
    1600, Chinese Society for Electrical Engineering (40): : 3592 - 3601
  • [5] Robust Delay Compensation Strategy for LCL-Type Grid-Connected Inverter in Weak Grid
    Ding, Xin
    Xue, Ruinan
    Zheng, Tianzhi
    Kong, Fannie
    Chen, Yanming
    IEEE ACCESS, 2022, 10 : 67639 - 67652
  • [6] Resonance modal analysis for multiple LCL-type grid-connected inverters in weak grid
    Li J.
    Ruan X.
    Li Y.
    Li R.
    Liu S.
    Sun W.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (02): : 346 - 355
  • [7] High Robustness Grid Current Feedback Active Damping Strategy for LCL-type Grid-connected Inverter in Weak Grid
    Dong G.
    Xu Z.
    Sun P.
    Li Q.
    Chen Y.
    Dianwang Jishu/Power System Technology, 2024, 48 (04): : 1672 - 1680
  • [8] Controller parameters design of a fractional-order LCL-type grid-connected inverter
    Jiang, Yuanhuai
    Wang, Xiaogang
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (02) : 769 - 792
  • [9] Systematic controller design for digitally controlled LCL-type grid-connected inverter with grid-current-feedback active damping
    Zhu, Donghai
    Zou, Xudong
    Zhao, Yingying
    Peng, Teng
    Zhou, Shiying
    Kang, Yong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 110 : 642 - 652
  • [10] Full-State Feedback Based Active Damping Control Design for LCL-type Grid-Connected Converter under Weak Grid
    Guo, Zhengchen
    Zou, Xudong
    Huang, Yanrun
    Kang, Yong
    Zou, Kaifeng
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 1360 - 1365