Impedance Analysis Using High-resolution Impedance Manometry Facilitates Assessment of Pharyngeal Residue in Patients With Oropharyngeal Dysphagia

被引:9
|
作者
Lee, Tae Hee [1 ]
Lee, Joon Seong [1 ]
Hong, Su Jin [2 ]
Lee, Ji Sung [3 ]
Jeon, Seong Ran [1 ]
Kim, Wan Jung [4 ]
Kim, Hyun Gun [1 ]
Cho, Joo Young [1 ]
Kim, Jin-Oh [1 ]
Cho, Jun-Hyung [1 ]
Kim, Mi-Young [1 ]
Kwon, Soon Ha [1 ]
机构
[1] Soonchunhyang Univ, Coll Med, Ctr Digest Dis, Inst Digest Res, Seoul, South Korea
[2] Soonchunhyang Univ, Coll Med, Dept Internal Med, Puchon, Gyeonggi Do, South Korea
[3] Soonchunhyang Univ, Coll Med, Biostat Consulting Unit, Seoul, South Korea
[4] Soonchunhyang Univ Hosp, Dept Internal Med, Gumi, Gyeongsangbuk D, South Korea
关键词
Deglutition disorders; Diagnosis; Pharynx; FIBEROPTIC ENDOSCOPIC EVALUATION; UPPER ESOPHAGEAL SPHINCTER; VIDEOFLUOROSCOPY; ASPIRATION;
D O I
10.5056/jnm14007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims Impedance analysis using high-resolution impedance manometry (HRIM) enables the recognition of pharyngeal residue in patients with oropharyngeal dysphagia. The aims of this study were to evaluate appropriate criteria for impedance analysis in a large patient cohort, as well as the diagnostic accuracy and agreement of analysis performed by HRIM trainees. Methods We reviewed 33 controls (13 males; median age, 61.2 years) and 104 oropharyngeal dysphagia patients (61 males; median age, 70.4 years) who underwent a flexible endoscopic evaluation of swallowing study (FEES) and HRIM. Two experts compared the pharyngeal residue on FEES and impedance color pattern at 1,000, 1,500 and 2,000 Omega of the impedance bar. Three trainees were given a 60 minutes tutorial to determine the diagnostic accuracy and agreement of this analysis. Results The diagnostic sensitivity of experts for predicting liquid residue was 73.1% for 1,000 Omega, 96.2% for 1,500 Omega and 100% for 2,000 Omega. Significantly higher sensitivity was observed at 1,500 Omega compared to 1,000 Omega (P < 0.001). The diagnostic specificity of experts for liquid residue was 98.3% for 1,000 Omega, 96.6% for 1,500 Omega and 83.1% for 2,000 Omega. There was a higher specificity at 1,500 Omega compared to 2,000 Omega (P = 0.008). The kappa value among the 3 trainees was 0.89 and the diagnostic accuracy of the trainees for liquid residue was comparable to that of the experts. Conclusions The impedance analysis at 1,500 Omega provides more accurate information for the detection of liquid residue, irrespective of the level of expertise.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [21] High-resolution manometry combined with impedance measurements discriminates the cause of dysphagia in children
    Rommel, Nathalie
    Omari, Taher I.
    Selleslagh, Margot
    Kritas, Stamatiki
    Cock, Charles
    Rosan, Rachel
    Rodriguez, Leonel
    Nurko, Samuel
    EUROPEAN JOURNAL OF PEDIATRICS, 2015, 174 (12) : 1629 - 1637
  • [22] High-resolution impedance manometry findings in patients with nutcracker esophagus
    Hoshino, Masato
    Sundaram, Abhishek
    Juhasz, Arpad
    Yano, Fumiaki
    Tsuboi, Kazuto
    Lee, Tommy H.
    Mittal, Sumeet K.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 (03) : 592 - 597
  • [23] High-Resolution Impedance Manometry Findings in Patients With Epiphrenic Diverticulum
    Yamamoto, Se Ryung
    Nandipati, Kalyana C.
    Pallati, Pradeep K.
    Lee, Tommy H.
    Mittal, Sumeet K.
    GASTROENTEROLOGY, 2013, 144 (05) : S1077 - S1077
  • [24] A Case of Rumination Documented by Using High-resolution Impedance Manometry
    Lee, Tae Hee
    JOURNAL OF NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 19 (02) : 259 - 260
  • [25] The use of high-resolution pharyngeal manometry as biofeedback in dysphagia therapy
    O'Rourke, Ashli
    Humphries, Kate
    ENT-EAR NOSE & THROAT JOURNAL, 2017, 96 (02) : 56 - +
  • [26] Automated High-Resolution Impedance Manometry Analysis Detects Subtle Esophageal Motor Dysfunction in Patients Who Have Non-Obstructive Dysphagia With Normal Manometry/Impedance Study
    Nguyen, Nam Q.
    Singendonk, Maartje M.
    Myers, Jennifer C.
    Tippett, Marcus
    Bambrick, Jenna E.
    Holloway, Richard H.
    Omari, Taher
    GASTROENTEROLOGY, 2014, 146 (05) : S685 - S686
  • [27] High-resolution impedance manometry parameters in the evaluation of esophageal function of non-obstructive dysphagia patients
    Singendonk, Maartje J.
    Lin, Zhiyue
    Scheerens, Charlotte
    Tack, Jan
    Carlson, Dustin A.
    Omari, Taher, I
    Pandolfino, John E.
    Rommel, Nathalie
    NEUROGASTROENTEROLOGY AND MOTILITY, 2019, 31 (02):
  • [28] ASSESSMENT OF ESOPHAGEL BOLUS TRANSIT AND PERISTALTIC INTEGRITY USING HIGH-RESOLUTION IMPEDANCE MANOMETRY
    Hamada, Mariko
    Akiyama, Junichi
    Iida, Tatsuhiro
    Izumi, Atsuko
    Kimura, Kana
    Nishiie, Yuriko
    Moriyasu, Shiori
    Kihira, Eri
    Otake, Yuki
    Okubo, Hidetaka
    Imbe, Koh
    Watanabe, Kazuhiro
    Nagata, Naoyoshi
    Yokoi, Chizu
    Kobayakawa, Masao
    Uemura, Naomi
    Kuribayashi, Shiko
    Kusano, Motoyasu
    GASTROENTEROLOGY, 2019, 156 (06) : S999 - S999
  • [29] The Impact of Bolus Rheology on Physiological Swallowing Parameters Derived by Pharyngeal High-Resolution Manometry Impedance
    Omari, T.
    Ross, A.
    Schar, M.
    Campbell, J.
    Lewis, D. A.
    Robinson, I.
    Farahani, M.
    Cock, C.
    Mossel, B.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2024,
  • [30] Antinuclear Antibodies in Patients Undergoing High-Resolution Esophageal Manometry with Impedance
    Lee, Susie O.
    Irfan, Saad
    Behanan, Michael
    Morejon, Ivanna
    Rim, Daniel
    Parkman, Henry P.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2024, 119 (10S): : S410 - S411