Investigation of PEMFC Stack Operating at Elevated Temperature

被引:0
|
作者
Zhang, Hao [1 ,2 ]
Yang, Daijun [1 ,2 ]
Tao, Kan [2 ]
Zheng, Xiaoliang [1 ,2 ]
Ma, Jianxin [1 ,2 ]
机构
[1] Tongji Univ, Sch Automot Studies, 4800 Caoan Rd, Shanghai 201804, Peoples R China
[2] Tongji Univ, Clean Energy Automot Engn Ctr, Shanghai 201804, Peoples R China
关键词
PEMFC; Elevated temperature; Relative humidity; Tolerance to CO; FUEL-CELLS; PERFORMANCE; MEMBRANES; ACID;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
PEMFC operating at elevated temperature has many advantages compared to low temperature PEMFC. With the adoption of short side chain, low EW PFSA membrane, the operating temperature of a 100W stack was elevated to 95 C-degrees to investigate its performance. The stack performance was tested with (1)60% RH air and 70% RH H-2, (2)60% RH air and dry H-2, respectively. The results showed that average cell power density with dry H-2 was 30% lower than that with 70% RH H-2. Furthermore, the cells presented the best uniformity when operating at 85 C-degrees. The stack tolerance to CO at elevated temperature was also investigated with 5ppm, 10ppm and 20ppm CO, respectively. The results demonstrated that elevating the operating temperature to 95 C-degrees could improve the anode catalyst tolerance to CO, and when CO concentration doubled, the performance attenuation rate of stack doubled as well. Copyright Form of EVS25.
引用
收藏
页码:961 / 964
页数:4
相关论文
共 50 条
  • [21] EXPERIMENTAL AND NUMERICAL INVESTIGATION OF THE EFFECT OF VARIABLE OPERATING CONDITIONS ON PEMFC PERFORMANCE
    Kahraman, Huseyin
    THERMAL SCIENCE, 2023, 27 (4B): : 3089 - 3100
  • [22] Experimental study on the influence of operating conditions on performance decline with periodic anode purges in a vehicular PEMFC stack
    Lu, Yikang
    Wang, Xuhui
    Yang, Guang
    Gong, Dapeng
    Xu, Sichuan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 69 : 1276 - 1286
  • [23] Study of dynamic behavior for PEMFC stack
    Park, Kwangjin
    Bae, Joongmyen
    Proceedings of the 3rd International Conference on Fuel Cell Science, Engineering, and Technology, 2005, : 191 - 195
  • [24] Numerical simulation of a mini PEMFC stack
    Liu, Zhixiang
    Mao, Zongqiang
    Wang, Cheng
    Zhuge, Weilin
    Zhang, Yangjun
    JOURNAL OF POWER SOURCES, 2006, 160 (02) : 1111 - 1121
  • [25] Operating Temperature Effects on Water Transport Behavior in a Single Cell PEMFC
    Erni, Misran
    Suhaimi, Nik Mat Hassan
    Ramli, Wan Wan Daud
    Herianto, Edy Majlan
    Miftah, Kurniawan
    ADVANCES IN MECHANICAL ENGINEERING, PTS 1-3, 2011, 52-54 : 1153 - 1158
  • [26] Numerical Study of Effects of Operating Conditions on the Performance of High Temperature PEMFC
    Kim, Kyoungyoun
    Sohn, Young-Jun
    Kim, Minjin
    Yang, Tae-Hyun
    JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY, 2010, 13 (04): : 283 - 289
  • [27] Design of Forced Air-cooling Structure for Elevated Temperature PEMFC
    Zheng, Xiaoliang
    Yang, Daijun
    Tao, Kan
    Zhang, Hao
    Ma, Jianxin
    25TH WORLD BATTERY, HYBRID AND FUEL CELL ELECTRIC VEHICLE SYMPOSIUM AND EXHIBITION PROCEEDINGS, VOLS 1 & 2, 2010, : 965 - 969
  • [28] Design of forced air-cooling structure for elevated temperature PEMFC
    Zheng X.
    Yang D.
    Tao K.
    Zhang H.
    Ma J.
    World Electric Vehicle Journal, 2010, 4 (03) : 464 - 469
  • [29] Dual temperature parameter control of PEMFC stack based on improved differential evolution algorithm
    Chen, Xi
    Feng, Wentao
    You, Shuhuai
    Hu, Yukang
    Wan, Yixin
    Zhao, Bin
    RENEWABLE ENERGY, 2025, 241
  • [30] Optimizing temperature distribution in a PEMFC stack: A computational study on cooling plate and coolant dynamics
    Wang, Yang
    Sun, Z. Y.
    Yang, Liu
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 97 : 88 - 103