DC negative corona discharge characteristics in air flowing transversely and longitudinally through a needle-plate electrode gap

被引:21
|
作者
Berendt, Artur [1 ]
Budnarowska, Magdalena [2 ]
Mizeraczyk, Jerzy [2 ]
机构
[1] Polish Acad Sci, Inst Fluid Flow Machinery, Fiszera 14, PL-80231 Gdansk, Poland
[2] Gdynia Maritime Univ, Dept Marine Elect, Morska 81-87, PL-81225 Gdynia, Poland
关键词
DC negative corona discharge in air; Corona discharges in airflow; DC corona modes; Trichel pulses; PULSES; WIND;
D O I
10.1016/j.elstat.2018.01.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CThe electrical characteristics of a steady-state DC negative corona discharge in air flowing transversely or longitudinally in relation to the needle-to-plate (or mesh) electrode axis were experimentally investigated. The velocity of air flowing into the corona discharge chamber was limited to a range from 0 to 6 m/s, typical of electrostatic precipitators, gas ionisation sensors and EHD pumps. The investigations showed that in this airflow velocity range three discharge current modes of the DC negative corona could exist: the Trichel-pulse corona mode, the 'Trichel pulses superimposed on the steady current (or DC) component' mode and the steady glow (the steady current or DC) corona mode, regardless of the airflow direction. The average corona discharge current, which is a macroscopic corona discharge parameter, was almost not affected by the airflow. However, both microscopic corona discharge parameters: the electric charge and the repetition frequency of Trichel pulses were influenced by the airflow. The transverse airflow caused an increase in the electric charge and a decrease in the repetition rate of Trichel pulses, the both by about 25% at a velocity of 6 m/s. In the case of longitudinal airflow the average corona current slightly increased when the airflow was directed towards the mesh and decreased when the airflow was directed towards the needle tip. Similarly as in the case of transverse airflow, the electric charge and the repetition frequency of Trichel pulses were affected by the longitudinal airflow. The electric charge and the repetition frequency of Trichel pulses increased and decreased, respectively, with growing airflow in the direction towards the needle electrode. The airflow growing in the direction towards the mesh electrode produced the opposite effect - the electric charge and the repetition frequency of Trichel pulses decreased and increased, respectively. The opposite behaviours of the electric charge and the repetition frequency of Trichel pulses with growing airflow velocity could explain the weak dependence of the negative corona average current on transverse or longitudinal airflow. Therefore, the independence of the negative corona average current of the airflow cannot be considered as sufficient proof that the airflow (up to 6 m/s) does not affect the negative corona parameters.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [31] Discharge characteristics of a needle-to-plate electrode at a micro-scale gap
    Wang, Ronggang
    Ji, Qizheng
    Zhang, Tongkai
    Xia, Qing
    Zhang, Yu
    Ouyang, Jiting
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (05)
  • [32] Discharge characteristics of a needle-to-plate electrode at a micro-scale gap
    王荣刚
    季启政
    张桐恺
    夏清
    张宇
    欧阳吉庭
    Plasma Science and Technology, 2018, (05) : 130 - 134
  • [33] Discharge characteristics of a needle-to-plate electrode at a micro-scale gap
    王荣刚
    季启政
    张桐恺
    夏清
    张宇
    欧阳吉庭
    Plasma Science and Technology, 2018, 20 (05) : 130 - 134
  • [34] Influence of the High-Speed Sand Dust Environment on Breakdown Characteristics of Needle-Plate Air Gap
    Bai, S. X.
    Liu, K.
    Song, L.
    Peng, Y.
    Lei, Z. Y.
    Du, Y.
    Yin, X. B.
    Zhang, X. Q.
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 695 - 699
  • [35] Spectroscopic Characteristics of DC Excited Atmospheric Pressure Glow Discharges Generated in a Needle-Plate Electrode Device and a Needle-Water Electrode One
    Li Xue-chen
    Bao Wen-ting
    Jia Peng-ying
    Zhao Huan-huan
    Di Cong
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (01) : 16 - 19
  • [36] Negative DC corona discharge current characteristics in a flowing two-phase (air plus suspended smoke particles) fluid
    Berendt, Artur
    Domaszka, Magdalena
    Mizeraczyk, Jerzy
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2017, 77 (03):
  • [37] Characteristics of negative DC corona discharge in a wire-plate configuration at high temperatures
    Yan, Pei
    Zheng, Chenghang
    Xiao, Gang
    Xu, Xi
    Gao, Xiang
    Luo, Zhongyang
    Cen, Kefa
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 139 : 5 - 13
  • [38] Characteristics of laser-induced streamer corona discharge in a needle-to-plate electrode system
    Kanazawa, S
    Ito, T
    Shuto, Y
    Ohkubo, T
    Nomoto, Y
    Mizeraczyk, J
    JOURNAL OF ELECTROSTATICS, 2002, 55 (3-4) : 343 - 350
  • [39] Parameter optimization of excited OH radical in multi-needle to plate negative DC corona discharge
    Ge, Hui
    Zhang, Lingling
    Yan, Ling
    Mi, Dong
    Zhu, Yimin
    JOURNAL OF ELECTROSTATICS, 2011, 69 (06) : 529 - 532
  • [40] Effect of humidity and air pressure on the discharge modes transition characteristics of negative DC corona
    Chen, She
    Li, Kelin
    Wang, Feng
    Sun, Qiuqin
    Zhong, Lipeng
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (08) : 1212 - 1218