DC negative corona discharge characteristics in air flowing transversely and longitudinally through a needle-plate electrode gap

被引:21
|
作者
Berendt, Artur [1 ]
Budnarowska, Magdalena [2 ]
Mizeraczyk, Jerzy [2 ]
机构
[1] Polish Acad Sci, Inst Fluid Flow Machinery, Fiszera 14, PL-80231 Gdansk, Poland
[2] Gdynia Maritime Univ, Dept Marine Elect, Morska 81-87, PL-81225 Gdynia, Poland
关键词
DC negative corona discharge in air; Corona discharges in airflow; DC corona modes; Trichel pulses; PULSES; WIND;
D O I
10.1016/j.elstat.2018.01.006
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
CThe electrical characteristics of a steady-state DC negative corona discharge in air flowing transversely or longitudinally in relation to the needle-to-plate (or mesh) electrode axis were experimentally investigated. The velocity of air flowing into the corona discharge chamber was limited to a range from 0 to 6 m/s, typical of electrostatic precipitators, gas ionisation sensors and EHD pumps. The investigations showed that in this airflow velocity range three discharge current modes of the DC negative corona could exist: the Trichel-pulse corona mode, the 'Trichel pulses superimposed on the steady current (or DC) component' mode and the steady glow (the steady current or DC) corona mode, regardless of the airflow direction. The average corona discharge current, which is a macroscopic corona discharge parameter, was almost not affected by the airflow. However, both microscopic corona discharge parameters: the electric charge and the repetition frequency of Trichel pulses were influenced by the airflow. The transverse airflow caused an increase in the electric charge and a decrease in the repetition rate of Trichel pulses, the both by about 25% at a velocity of 6 m/s. In the case of longitudinal airflow the average corona current slightly increased when the airflow was directed towards the mesh and decreased when the airflow was directed towards the needle tip. Similarly as in the case of transverse airflow, the electric charge and the repetition frequency of Trichel pulses were affected by the longitudinal airflow. The electric charge and the repetition frequency of Trichel pulses increased and decreased, respectively, with growing airflow in the direction towards the needle electrode. The airflow growing in the direction towards the mesh electrode produced the opposite effect - the electric charge and the repetition frequency of Trichel pulses decreased and increased, respectively. The opposite behaviours of the electric charge and the repetition frequency of Trichel pulses with growing airflow velocity could explain the weak dependence of the negative corona average current on transverse or longitudinal airflow. Therefore, the independence of the negative corona average current of the airflow cannot be considered as sufficient proof that the airflow (up to 6 m/s) does not affect the negative corona parameters.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [1] Development Processes of Positive and Negative DC Corona under Needle-Plate Electrode in air
    Liu, Min
    Tang, Ju
    Yao, Qiang
    Miao, Yulong
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [2] DC Negative Streamer Discharge Characteristics of 'Needle-plate' Air Gap Considering Influence of Voltage Rise
    Su M.
    An Y.
    Wang Q.
    Sha X.
    Hu Y.
    Qu L.
    Dianwang Jishu/Power System Technology, 2024, 48 (04): : 1711 - 1720
  • [3] Microanalysis of Active Nitrogen Oxides (RONS) Generation Characteristics during DC Negative Corona Discharge at a Needle-Plate Electrode
    Shi, Jinqiang
    Jin, Fubao
    Ma, Shangang
    Liu, Xinhe
    Leng, Xuejian
    Chen, Keyuan
    PLASMA, 2023, 6 (04) : 649 - 662
  • [4] Optical study of OH radical in a needle-plate DC corona discharge
    Zheng, W.
    Liu, F.
    Wang, W.
    Wang, D.
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2007, 38 (02): : 153 - 159
  • [5] Negative Corona Discharge Characteristics of Needle-plate and Rod-plate Structures Under Different Temperatures
    Feng Q.
    Huang L.
    Liu D.
    Wu J.
    Qi H.
    Dang Z.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (05): : 1847 - 1856
  • [6] Discharge phenomena of short-air-gap in needle-plate electrode based on fractal theory
    Zheng Dian-Chun
    Ding Ning
    Shen Xiang-Dong
    Zhao Da-Wei
    Zheng Qiu-Ping
    Wei Hong-Qing
    ACTA PHYSICA SINICA, 2016, 65 (02)
  • [7] Analysis of the Movement Characteristics of Corona Winds during Needle-Plate Discharge
    Deng, Jiewen
    Qu, Hongwei
    Lin, Jianqing
    Yu, Guoxin
    Deng, Qin
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2016, 34 (04) : 574 - 580
  • [8] Ultraviolet Characteristic Parameter of Needle-plate Model AC/DC Corona Discharge
    Li Z.
    Jiang X.
    Li L.
    Hu Q.
    Hu J.
    Zhang Z.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (05): : 1677 - 1684
  • [9] Research on Electron Density in DC Needle-Plate Corona Discharge at Atmospheric Pressure
    Liu Zhi-qiang
    Guo Wei
    Liu Tao-tao
    Wu Wen-shuo
    Liu Shu-min
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2013, 33 (11) : 2900 - 2902
  • [10] Research of relative luminous intensity of negative corona discharge of needle-plate in the atmosphere
    Liu, Zhiqiang
    Liu, Tie
    Guo, Wei
    Wu, Wenshuo
    Liu, Shumin
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (04): : 1201 - 1206