Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T

被引:15
|
作者
Lee, Young Han [1 ,2 ]
Lim, Daekeon [1 ,2 ]
Kim, Eunju [3 ,4 ]
Kim, Sungjun [1 ,2 ]
Song, Ho-Taek [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Res Inst Radiol Sci,Med Convergence Res Inst, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
[3] Philips Healthcare, Clin Sci, Seoul, South Korea
[4] Hanyang Univ, Grad Sch Biomed Sci & Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Magnetic resonance; Metallic artifact reduction; Slice encoding for metal artifact correction; Fat suppression; Metallic artifacts; MR;
D O I
10.1016/j.mri.2014.04.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 31 in patients with spinal prostheses. Methods: Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used. Results: Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected. Conclusion: SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and pen-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [21] T2-weighted magnetic resonance imaging to assess myocardial oedema
    Bohl, Steffen
    Friedrich, Matthias G.
    Schulz-Menger, Jeanette
    HEART, 2010, 96 (04) : 310 - 310
  • [22] Hyperintensity on T2-weighted magnetic resonance imaging in Takotsubo cardiomyopathy
    Otsuka, Yoritaka
    Noguchi, Teruo
    Goto, Yoichi
    Nonogi, Hiroshi
    Yamada, Naoaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 130 (01) : 113 - 116
  • [23] Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging
    Lee, Seung Hyun
    Lee, Young Han
    Hahn, Seok
    Yang, Jaemoon
    Song, Ho-Taek
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2018, 59 (08) : 959 - 965
  • [24] Fat-saturated T2-weighted TSE MR sequence: Diagnostic alternative to spiral CTAP in the assessment of liver metastases
    Helmberger, H
    Lenz, MW
    Sendler, A
    Vogel, US
    Bautz, WA
    Gerhardt, PO
    RADIOLOGY, 1996, 201 : 1209 - 1209
  • [25] Adhesive Capsulitis of the Shoulder: Value of Inferior Glenohumeral Ligament Signal Changes on T2-Weighted Fat-Saturated Images
    Teixeira, Pedro A. Gondim
    Balaj, Clemence
    Chanson, Anne
    Lecocq, Sophie
    Louis, Matthias
    Blum, Alain
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (06) : W589 - W596
  • [26] Hybrid Nanotrimers for Dual T1 and T2-Weighted Magnetic Resonance Imaging
    Cheng, Kai
    Yang, Meng
    Zhang, Ruiping
    Qin, Chunxia
    Su, Xinhui
    Cheng, Zhen
    ACS NANO, 2014, 8 (10) : 9884 - 9896
  • [27] T2-weighted turbo spin-echo magnetic resonance imaging of canine brain anatomy at 1.5T, 3T, and 7T field strengths
    Jacqmot, Olivier
    Van Thielen, Bert
    Hespel, Adrien-Maxence
    Luijten, Peter R.
    de Mey, Johan
    Van Binst, Anne
    Provyn, Steven
    Tresignie, Jonathan
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2022, 305 (01): : 222 - 233
  • [28] Reactive sclerosis: Hyperintense appearance on T2-weighted magnetic resonance imaging
    Kanberoglu, K
    Kantarci, F
    Yilmaz, MH
    ACTA RADIOLOGICA, 2005, 46 (07) : 708 - 715
  • [29] Neurotransmitter-Responsive Nanosensors for T2-Weighted Magnetic Resonance Imaging
    Hsieh, Vivian
    Okada, Satoshi
    Wei, He
    Garcia-Alvarez, Isabel
    Barandov, Ali
    Alvarado, Santiago Recuenco
    Ohlendorf, Robert
    Fan, Jingxuan
    Ortega, Athena
    Jasanoff, Alan
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2019, 141 (40) : 15751 - 15754
  • [30] Comparison of inversion recovery fast spin-echo (FSE) with T2-weighted fat-saturated FSE and T1-weighted MR imaging in bone marrow lesion detection
    Pui, MH
    Chang, SK
    SKELETAL RADIOLOGY, 1996, 25 (02) : 149 - 152