Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T

被引:15
|
作者
Lee, Young Han [1 ,2 ]
Lim, Daekeon [1 ,2 ]
Kim, Eunju [3 ,4 ]
Kim, Sungjun [1 ,2 ]
Song, Ho-Taek [1 ,2 ]
Suh, Jin-Suck [1 ,2 ]
机构
[1] Yonsei Univ, Coll Med, Dept Radiol, Res Inst Radiol Sci,Med Convergence Res Inst, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Severance Biomed Sci Inst, Seoul 120752, South Korea
[3] Philips Healthcare, Clin Sci, Seoul, South Korea
[4] Hanyang Univ, Grad Sch Biomed Sci & Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Magnetic resonance; Metallic artifact reduction; Slice encoding for metal artifact correction; Fat suppression; Metallic artifacts; MR;
D O I
10.1016/j.mri.2014.04.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background and Purpose: Fluid-sensitive MR imaging in postoperative evaluation is important, however, metallic artifacts is inevitable. The purpose is to investigate the feasibility of fat-saturated slice encoding for metal artifact correction (SEMAC)-corrected T2-weighted magnetic resonance (MR) at 31 in patients with spinal prostheses. Methods: Following institutional review board approval, 27 SEMAC-encoded spinal MRs between September 2012 and October 2013 in patients with spinal metallic prostheses were analyzed. The MR images were scanned on a 3T MR system including SEMAC-corrected and uncorrected fast spin echo (FSE) T2-weighted MR images with fat-saturation. Two musculoskeletal radiologists compared the image sets and qualitatively analyzed the images using a five-point scale in terms of artifact reduction around the prosthesis, visualization of the prosthesis and pedicle, and intervertebral neural foramina. Quantitative assessments were performed by calculating the ratio of signal intensity from the fixated vertebra and that from upper level vertebra. For statistical analyses, paired t-test was used. Results: Fat-saturated SEMAC-corrected T2-weighted MR images enabled significantly improved metallic artifact reduction (P < 0.05). Quantitative evaluation of the signal intensity ratio of screw-fixated vertebra and upper level vertebra showed a significantly lower ratio on fat-saturated SEMAC images (P < 0.05), however, the high signal intensity of signal pile-up could be not completely corrected. Conclusion: SEMAC correction in fat-suppressed T2-weighted MR images can overcome the signal loss of metallic artifacts and provide improved delineation of the pedicle screw and pen-prosthetic region. Signal pile-up, however, could not be corrected completely, therefore readers should be cautious in the evaluation of marrow around the prosthesis. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1001 / 1005
页数:5
相关论文
共 50 条
  • [1] Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T2-weighted Images
    Lee, Young Han
    Hahn, Seok
    Kim, Eunju
    Suh, Jin-Suck
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (04) : 371 - 378
  • [2] Hyperintensity signal in the joint space of the temporomandibular joint on fat-saturated T2-weighted magnetic resonance imaging
    Yura, Shinya
    Nobata, Koji
    Shima, Tsuyoshi
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (08): : 621 - 623
  • [3] Diagnostic accuracy of fat-saturated T2-weighted magnetic resonance imaging in the diagnosis of perforation of the articular disc of the temporomandibular joint
    Yura, Shinya
    Nobata, Koji
    Shima, Tsuyoshi
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2012, 50 (04): : 365 - 368
  • [4] Spectrum of imaging findings on axial T2-weighted fat-saturated imaging of the lumbar spine
    Csillag, A.
    Ly, J.
    CLINICAL RADIOLOGY, 2014, 69 (09) : 980 - 987
  • [5] Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI
    Lee, Young Han
    Lim, Daekeon
    Kim, Eunju
    Kim, Sungjun
    Song, Ho-Taek
    Suh, Jin-Suck
    MAGNETIC RESONANCE IMAGING, 2013, 31 (05) : 703 - 706
  • [6] Feasibility of virtual T2-weighted fat-saturated breast MRI images by convolutional neural networks
    Andrzej Liebert
    Dominique Hadler
    Chris Ehring
    Hannes Schreiter
    Luise Brock
    Lorenz A. Kapsner
    Jessica Eberle
    Ramona Erber
    Julius Emons
    Frederik B. Laun
    Michael Uder
    Evelyn Wenkel
    Sabine Ohlmeyer
    Sebastian Bickelhaupt
    European Radiology Experimental, 9 (1)
  • [7] T2-weighted fast SE fat-saturated MR sequences in the orbit
    Goldberg, PA
    Rothman, MI
    Baganz, MD
    Simon, JA
    Zoarski, GH
    RADIOLOGY, 1996, 201 : 437 - 437
  • [8] Comparison of fat-saturated T2-weighted and contrast-enhanced fat-saturated Ti-weighted sequences in MR imaging of sacroiliac joints in diagnosing active sacroiliitis
    Ozgen, Ali
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2593 - 2596
  • [9] Optimal 3-T MRI for depiction of the finger A2 pulley: comparison between T1-weighted, fat-saturated T2-weighted and gadolinium-enhanced fat-saturated T1-weighted sequences
    Goncalves-Matoso, Vasco
    Guntern, Daniel
    Gray, Anne
    Schnyder, Pierre
    Picht, Carmen
    Theumann, Nicolas
    SKELETAL RADIOLOGY, 2008, 37 (04) : 307 - 312
  • [10] Optimal 3-T MRI for depiction of the finger A2 pulley: comparison between T1-weighted, fat-saturated T2-weighted and gadolinium-enhanced fat-saturated T1-weighted sequences
    Vasco Goncalves-Matoso
    Daniel Guntern
    Anne Gray
    Pierre Schnyder
    Carmen Picht
    Nicolas Theumann
    Skeletal Radiology, 2008, 37 : 307 - 312