A new metric for drill location for Navigated Control in navigated dental implantology

被引:5
|
作者
Koulechov, K [1 ]
Lueth, T [1 ]
机构
[1] MKG Klin Navigat & Robot, D-13353 Berlin, Germany
关键词
surgical navigation; dental implantology; precision; accuracy; benchmark;
D O I
10.1016/j.ics.2004.03.228
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this paper, a new metric for the evaluation of the drill location for navigation systems in dental implantology is presented. The influence of this metric on the precision of the navigation system is evaluated. For this evaluation, a highly accurate measurement method for the measurement of the drilled holes in phantom jaws is developed. The presented results are partial results of the project "Navigated Control in dental implantology". With Navigated Control, the power of handheld instruments, e.g., of a surgical drill, is adjusted depending on the deviation between actual location of the instrument and its desired location. The application of Navigated Control in dental implantology will lead to higher safety for the patient and the surgeon. The results are: (1) the described measurement method for the measurement of the drilled holes in phantom jaws is highly accurate and reproducible (the precision of the measurement method is higher than 0.04 mm and higher than 0.1degrees) and is suitable as a benchmark, (2) even the current simple implementation of Navigated Control will increase safety while keeping the high precision of up-to-date navigation systems, (3) the used new metric leads to higher comfort of Navigated Control in dental implantology. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:1220 / 1225
页数:6
相关论文
共 50 条
  • [21] A new concept for navigated laser surgery
    Stopp, Sebastian
    Deppe, Herbert
    Lueth, Tim
    LASERS IN MEDICAL SCIENCE, 2008, 23 (03) : 261 - 266
  • [22] Navigated control:: A new concept in computer assisted ENT-Surgery
    Strauss, G
    Koulechov, K
    Richter, R
    Dietz, A
    Meixensberger, J
    Trantakis, C
    Lüth, T
    LARYNGO-RHINO-OTOLOGIE, 2005, 84 (08) : 567 - 576
  • [23] Navigated control [registered trademark] - A new approach for the exact shaping at the spine
    Luth, T.
    Hein, A.
    VDI Berichte, 2002, (1679): : 515 - 522
  • [24] Pedicle screw placement with use of a navigated surgical drill at subaxial cervical spine
    Satake, Kotaro
    Kanemura, Tokumi
    Ito, Kenyu
    Tanaka, Satoshi
    Morita, Yoshinori
    Nakashima, Hiroaki
    Ouchida, Jun
    Imagama, Shiro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2021, 88 : 28 - 33
  • [25] Navigated control in functional endoscopic sinus surgery
    Strauss, G
    Koulechov, K
    Richter, R
    Dietz, A
    Trantakis, C
    Lüth, T
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (03): : 31 - 41
  • [26] Dental Implant Surgery: From Conventional to Guided to Navigated Approach
    Kasten B.
    Arastu A.
    Panchal N.
    Current Oral Health Reports, 2018, 5 (2) : 140 - 146
  • [27] Navigated Control Functional: Combining Surgical Navigation and Real-time Nerve Activity Measurement for a Drill's Motor Control
    Shi, Jiaxi
    Heininger, Sebastian
    Lueth, Tim C.
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011,
  • [28] A New Procedure for Frameless Computer Navigated Stereotaxy
    T. Brommeland
    R. Hennig
    Acta Neurochirurgica, 2000, 142 : 443 - 448
  • [29] A new procedure for frameless computer navigated stereotaxy
    Brommeland, T
    Hennig, R
    ACTA NEUROCHIRURGICA, 2000, 142 (04) : 443 - 448
  • [30] Application of a Navigated Drill for Cervical Pedicle Screw Insertion at C3-6
    Takigawa, Tomoyuki
    Morita, Takuya
    Kajiki, Yuya
    Ito, Yasuo
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)