Selection of optimal infrared detector for pulsed photothermal profiling of vascular lesions

被引:4
|
作者
Majaron, B [1 ]
Milanic, M [1 ]
Choi, B [1 ]
Nelson, JS [1 ]
机构
[1] Jozef Stefan Inst, SI-1000 Ljubljana, Slovenia
关键词
pulsed photothermal radiometry; temperature depth profiling; image reconstruction; infrared absorption coefficient; port wine stain;
D O I
10.1117/12.540973
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Selection of infrared (IR) detector is a key consideration in designing an experimental setup for temperature depth profiling using pulsed photothermal radiometry (PPTR). In addition to common detector characteristics, such as the spectral response, detector noise, and response speed, application-specific details must be taken into account to ensure optimal system performance. When comparing detectors with different spectral responses, blackbody emission characteristics must be considered in terms of influence on radiometric signal amplitude, as well as on background shot noise. In PPTR, optical penetration depth of the sample in the acquisition spectral band is also an important factor, affecting the stability of the temperature profile reconstruction. Moreover, due to spectral variation of IR absorption coefficient in watery tissues, the acquisition band must be appropriately narrowed to ensure the validity of the customary approximation of a constant absorption coefficient value in signal analysis. This reduces the signal-to-noise ratio, adversely affecting the stability and quality of the temperature profile reconstruction. We present a performance analysis of PPTR depth profiling in human skin using commercially available IR detectors (InSb, HgCdTe), operating in different spectral bands. A measurement simulation example, involving a simple, hyper-Gaussian temperature profile, and realistic noise levels, illustrates their expected performance.
引用
收藏
页码:121 / 132
页数:12
相关论文
共 50 条
  • [21] Temperature measurements and analysis of skins with a high-speed infrared detector for the optimal parameter of Intense Pulsed Light
    Wakamatsu, S
    Ishikawa, N
    Negishi, K
    Tezuka, Y
    LASERS IN SURGERY AND MEDICINE, 2002, : 22 - 22
  • [22] A Compact, Pulsed Infrared Laser-Excited Photothermal Deflection Spectrometer
    Dada, Oluwatosin O.
    Bialkowski, Stephen E.
    APPLIED SPECTROSCOPY, 2011, 65 (02) : 201 - 205
  • [23] Automatic Selection of the Optimal Local Feature Detector
    Ferrarini, Bruno
    Ehsan, Shoaib
    Rehman, Naveed Ur
    Leonardis, Ales
    McDonald-Maier, Klaus D.
    IMAGE ANALYSIS AND RECOGNITION (ICIAR 2016), 2016, 9730 : 284 - 289
  • [24] PULSED PHOTOTHERMAL BEAM DEFLECTION FOR INFRARED-SPECTROSCOPY OF MOLECULES AT SURFACES
    BAIN, CD
    DAVIES, PB
    ONG, TH
    CHEMICAL PHYSICS LETTERS, 1992, 194 (4-6) : 391 - 397
  • [25] Determination of parameter β for dual-wavelength pulsed photothermal profiling of human skin
    Majaron, B
    Milner, TE
    Nelson, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (01): : 387 - 389
  • [26] Performance evaluation of pulsed photothermal profiling of port wine stain in human skin
    Li, BC
    Majaron, B
    Viator, JA
    Milner, TE
    Nelson, JS
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (06): : 2048 - 2055
  • [27] Spectral filtering for improved pulsed photothermal temperature profiling in agar tissue phantoms
    Milanic, Matija
    Majaron, Boris
    Nelson, J. Stuart
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [28] Pulsed Dye Laser Treatment of Vascular Lesions in Childhood
    Barcot, Zoran
    Zupancic, Bozidar
    ACTA DERMATOVENEROLOGICA CROATICA, 2010, 18 (03) : 201 - 208
  • [29] The pulsed dye laser for cutaneous vascular and nonvascular lesions
    Richards, KA
    Garden, JM
    SEMINARS IN CUTANEOUS MEDICINE AND SURGERY, 2000, 19 (04) : 276 - 286
  • [30] DETECTION OF PULSED FAR INFRARED LASER RADIATION BY A GE - IN DETECTOR
    TAKEUCHI, N
    KOBAYASHI, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1967, 6 (12) : 1462 - +