High sensitivity refractive index sensor based on splicing points tapered SMF-PCF-SMF structure Mach-Zehnder mode interferometer

被引:128
|
作者
Wang, Qi [1 ,2 ]
Kong, Lingxin [1 ]
Dang, Yunli [1 ]
Xia, Feng [1 ]
Zhang, Yongwei [1 ]
Zhao, Yong [1 ,2 ]
Hu, Haifeng [1 ]
Li, Jin [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Liaoning, Peoples R China
[2] Northeastern Univ, State Key Lab Synthet Automat Proc Ind, Shenyang 110819, Liaoning, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会; 高等学校博士学科点专项科研基金;
关键词
Optical fiber sensor; Refractive index measurement; Mach-Zehnder interference; Photonic crystal fiber; High sensitivity; Splicing points taper; PHOTONIC CRYSTAL FIBER;
D O I
10.1016/j.snb.2015.11.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper proposed and studied a Mach-Zehnder mode interferometric refractive index sensor, which is based on splicing points tapered SMF-PCF-SMF (SMF, single-mode fiber; PCF, photonic crystal fiber) structure. For the reason that the effective refractive index of photonic crystal fiber cladding high-order modes near fiber core are more sensitive to surrounding refractive index changes, the refractive index measurement sensitivity of splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer can be enhanced further through tapering the splicing points. Relations between refractive index measurement sensitivity and photonic crystal fiber length and taper waist diameter are studied through numerical simulations and experiments. Simulation and experimental results show that sensitivity will be increased with the increase of photonic crystal fiber length and the decrease of taper waist diameter. In the refractive range of 1.3333-1.3737, splicing points tapered SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm and taper waist diameter of 60.4 mu m has refractive index measurement sensitivity of 260.8 nm/RIU, compared with sensitivity of 224.2 nm/RIU of direct splicing SMF-PCF-SMF Mach-Zehnder mode interferometer with PCF length of 4 cm, the sensitivity increased by 16.3%. The research shows that the sensing structure is with good linearity and repeatability. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:213 / 220
页数:8
相关论文
共 50 条
  • [21] Highly sensitive refractive index sensing based on a novel Mach-Zehnder interferometer with TCF-PCF composite structure
    Dong, Xinran
    Zeng, Li
    Chu, Dongkai
    Sun, Xiaoyan
    Duan, Ji'an
    INFRARED PHYSICS & TECHNOLOGY, 2022, 123
  • [22] Tapered Photonic Crystal Fiber Based Mach-Zehnder Interferometer for Enhanced Refractive Index Sensing
    Ahmed, Farid
    Jun, Martin B. G.
    2015 IEEE SENSORS, 2015, : 1355 - 1358
  • [23] Mach-Zehnder Interferometer Based on a Sandwich Fiber Structure for Refractive Index Measurement
    Ma, Yue
    Qiao, Xueguang
    Guo, Tuan
    Wang, Ruohui
    Zhang, Jing
    Weng, Yinyan
    Rong, Qiangzhou
    Hu, Manli
    Feng, Zhongyao
    IEEE SENSORS JOURNAL, 2012, 12 (06) : 2081 - 2085
  • [24] A Mach-Zehnder interferometer based on peanut structure for temperature and refractive index measurement
    Yu, Xuelian
    Zuo, Shanshan
    Zhang, Yue
    Ma, Yiwei
    Wang, Ruoning
    Yang, Wenlei
    Tian, Ke
    Geng, Tao
    Wang, Pengfei
    OPTICAL REVIEW, 2022, 29 (06) : 492 - 497
  • [25] A Mach-Zehnder interferometer based on tapered dual side hole fiber for refractive index sensing
    Li, Song
    Zhao, Yujia
    OPTICAL FIBER TECHNOLOGY, 2018, 45 : 267 - 270
  • [26] Refractive Index Sensing of SMS Fiber Structure Based Mach-Zehnder Interferometer
    Shao, Min
    Qiao, Xueguang
    Fu, Haiwei
    Li, Huidong
    Jia, Zhenan
    Zhou, Hong
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (05) : 437 - 439
  • [27] PCF taper-based Mach-Zehnder interferometer for refractive index sensing in a PDMS detection cell
    Wu, Di
    Zhao, Yong
    Li, Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 1 - 4
  • [28] Ultrasensitive Refractive Index Sensor Based on Mach-Zehnder Interferometer and a 40μm Fiber
    Lei, Xueqin
    Dong, Xiaopeng
    Sun, Tong
    Grattan, Kenneth T., V
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (17) : 5625 - 5633
  • [29] Simultaneous measurement of refractive index and temperature with high sensitivity based on a multipath fiber Mach-Zehnder interferometer
    Jiang, Yajun
    Wang, Tao
    Liu, Chi
    Feng, Dingyi
    Jiang, Bichang
    Yang, Dexing
    Zhao, Jianlin
    APPLIED OPTICS, 2019, 58 (15) : 4085 - 4090
  • [30] REFRACTIVE INDEX SENSOR BASED ON MACH-ZEHNDER INTERFEROMETER FORMED BY TWO CASCADED SINGLE MODE FIBER CORNERS
    Shi, Qingguo
    Chen, Daru
    Jiang, Xiaogang
    Peng, Baojin
    Lei, Xueqin
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (11) : 2642 - 2645