Backprojection-filtration reconstruction for helical cone-beam CT with curved detectors

被引:0
|
作者
Zuo, Nianming [1 ]
Xia, Dan [1 ]
Sidky, Emil Y. [1 ]
Yu, Lifeng [1 ]
Zou, Yu [1 ]
Pan, Xiaochuan [1 ]
Tang, Tianzi [1 ]
机构
[1] Chinese Acad Sci, Inst Automat, Beijing 100864, Peoples R China
关键词
computed tomography (CT); image reconstruction; backprojection-filtration; curved detector;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Helical CT scanners with multi-row detectors have gained wide popularity in clinics. With increasing interest in extending the number of detector rows, the cone angle must be accounted for in image reconstruction algorithms. As the cone angle increases, artifacts in reconstructed images caused by approximate algorithms, such as the widely used FDK-based algorithms [1], become more of a factor that degrades the image quality. Recently, a novel reconstruction algorithm for helical cone-beam CT (CB-CT) has been proposed [2] [3], which is referred to as the backprojection-filtration algorithm. This algorithm requires theoretically minimum data to reconstruct a volume image. The original BPF algorithm was presented by assuming a flat-panel detector. However, most current multi-row detectors employed in clinic CT scanners are curved detectors. In this work, we modify the backprojection-filtration (BPF) algorithm to allow for reconstruction from data collected with a curved detector. We perform simulation studies using the Shepp-Logan phantom to evaluate the modified BPF algorithm.
引用
收藏
页码:2306 / 2309
页数:4
相关论文
共 50 条
  • [21] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [22] Hyperfast Perspective Cone-Beam Backprojection Hyperfast Perspective Cone-Beam Backprojection
    Kachelriess, Marc
    Knaup, Michael
    Bockenbach, Olivier
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1679 - 1683
  • [23] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [24] A weighted rebinned backprojection-filtration algorithm from partially beam-blocked data for a single-scan cone-beam CT with hybrid type scatter correction
    Min, Jonghwan
    Pua, Rizza
    Kim, Changhwan
    Park, Miran
    Lee, Jongha
    Ye, Sung-Joon
    Cho, Seungryong
    MEDICAL PHYSICS, 2019, 46 (03) : 1182 - 1197
  • [25] A hierarchical algorithm for fast backprojection in helical cone-beam tomography
    Bresler, Y
    Brokish, J
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 1420 - 1423
  • [26] A CONE-BEAM RECONSTRUCTION ALGORITHM USING SHIFT-VARIANT FILTERING AND CONE-BEAM BACKPROJECTION
    DEFRISE, M
    CLACK, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1994, 13 (01) : 186 - 195
  • [27] BPF-Type Reconstruction for Dual Helical Cone-Beam CT
    Zeng, Li
    Zou, Xiaobing
    CURRENT MEDICAL IMAGING, 2011, 7 (02) : 125 - 135
  • [28] Artifact analysis of approximate helical cone-beam CT reconstruction algorithms
    Köhler, T
    Proksa, R
    Bontus, C
    Grass, M
    Timmer, J
    MEDICAL PHYSICS, 2002, 29 (01) : 51 - 64
  • [29] Exact reconstruction of volumetric images in reverse helical cone-beam CT
    Cho, Seungryong
    Xia, Dan
    Pelizzari, Charles A.
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2008, 35 (07) : 3030 - 3040
  • [30] Tilted helical Feldkamp cone-beam reconstruction algorithm for multislice CT
    Hein, IA
    Taguchi, K
    Mori, I
    Kazama, M
    Silver, MD
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1901 - 1910