Spatial resolution in plantar pressure measurement

被引:35
|
作者
Lord, M
机构
[1] Medical Engineering and Physics, King's College Hospital (Dulwich), London SE22 8PT, East Dulwich Grove
关键词
foot pressure; spatial resolution; transducer dimensions; pedobarograph;
D O I
10.1016/S1350-4533(96)00057-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Peaks of pressure under the foot are of significance to the understanding and limitation of damage to plantar tissues. At present, many of the pressure measuring systems use a matrix of discrete transducer cells which each register the average pressure over their surface, and whose dimensions are such that they limit the accurate representation of the true peak pressure. The spatial filtering effect is investigated in this paper by analytical deduction from a pedobarographic record of high spatial resolution. For a barefoot diabetic patient who presents sharp peaks of pressure in the metatarsal region, the effect of notional cell dimensions is investigated through analysis of a typical record and shown to constitute a potentially significant error for cells of the dimensions of those in common use. The average pressure read from a transducer of area too mm(2) mar be of the order of 60-70 % of the true peak in barefoot standing, although this depends on the sharpness of the peaks. Errors are decreased when the more even in-shoe pressure distribution is considered. (C) 1997 Elsevier Science Ltd for IPEM.
引用
收藏
页码:140 / 144
页数:5
相关论文
共 50 条
  • [21] Dynamic Wave Measurement With a High Spatial Resolution Distributed Fiber Optic Pressure Sensor
    Hottges, Alessio
    Smaadahl, Mikkel
    Evers, Frederic M.
    Boes, Robert M.
    Rabaiotti, Carlo
    IEEE SENSORS JOURNAL, 2024, 24 (14) : 22387 - 22396
  • [22] MULTISTEP MEASUREMENT OF PLANTAR PRESSURE ALTERATIONS USING METATARSAL PADS
    CHANG, AH
    ABUFARAJ, ZU
    HARRIS, GF
    NERY, J
    SHEREFF, MJ
    FOOT & ANKLE INTERNATIONAL, 1994, 15 (12) : 654 - 660
  • [23] Plantar pressure measurement in diabetic foot disease: A scoping review
    Lockhart, Michael
    Dinneen, Sean F.
    O'Keeffe, Derek T.
    JOURNAL OF DIABETES INVESTIGATION, 2024, 15 (08) : 990 - 999
  • [24] An 8-FBGs Pressure Pad for COP Measurement of Plantar
    Zhang, Jing
    Wei, Qin
    2022 IEEE 10TH INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND NETWORKS (ICICN 2022), 2022, : 460 - 464
  • [25] An intelligent shoe-integrated system for plantar pressure measurement
    Chen, Meng
    Huang, Bufu
    Lee, Ka Keung
    Xu, Yangsheng
    2006 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS, VOLS 1-3, 2006, : 416 - +
  • [26] Barefoot plantar pressure measurement in Chronic Exertional Compartment Syndrome
    Roscoe, D.
    Roberts, A. J.
    Hulse, D.
    Shaheen, A.
    Hughes, M. P.
    Bennett, A.
    GAIT & POSTURE, 2018, 63 : 10 - 16
  • [27] Plantar pressure measurement system based on piezoelectric sensor: a review
    Li, Xiang
    Wang, Keyi
    Wang, Yan Lin
    Wang, Kui Cheng
    SENSOR REVIEW, 2022, 42 (02) : 241 - 249
  • [28] EXPLOITATION OF STEREOPHOTOGRAMMETRIC MEASUREMENT OF A FOOT IN ANALYSIS OF PLANTAR PRESSURE DISTRIBUTION
    Pankova, B.
    Koudelka, T.
    Pavelka, K.
    Janura, M.
    Jelen, K.
    XXIII ISPRS CONGRESS, COMMISSION V, 2016, 3 (05): : 153 - 158
  • [29] Foot Plantar Pressure Measurement System Using Optical Sensor
    Keatsamarn, Tanapon
    Pintavirooj, Chuchart
    2016 9TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2016,
  • [30] Simultaneous measurement of plantar pressure and shear forces in diabetic individuals
    Perry, JE
    Hall, JO
    Davis, BL