The frequency of re-planning and its variability dependent on the modification of the re-planning criteria and IGRT correction strategy in head and neck IMRT

被引:12
|
作者
Stoll, Markus [1 ]
Giske, Kristina [1 ]
Debus, Juergen [2 ]
Bendl, Rolf [1 ,3 ]
Stoiber, Eva Maria [1 ,2 ]
机构
[1] Deutsch Krebsforschungszentrum, Dept Med Phys Radiat Oncol, D-69120 Heidelberg, Germany
[2] Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[3] Heilbronn Univ, Fac Med Informat, Heilbronn, Germany
来源
RADIATION ONCOLOGY | 2014年 / 9卷
关键词
Image-guided radiation therapy; Head and neck cancer; Deformable image registration; Dose variations; Re-planning criteria; Re-planning frequency; DEFORMABLE IMAGE REGISTRATION; RADIATION-THERAPY; SETUP ERRORS; ADAPTIVE RADIOTHERAPY; CANCER; UNCERTAINTIES; ALGORITHM;
D O I
10.1186/1748-717X-9-175
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To analyse the frequency of re-planning and its variability dependent on the IGRT correction strategy and on the modification of the dosimetric criteria for re-planning for the spinal cord in head and neck IG-IMRT. Methods: Daily kV-control-CTs of six head and neck patients (= 175 CTs) were analysed. All volumes of interest were re-contoured using deformable image registration. Three IGRT correction strategies were simulated and the resulting dose distributions were computed for all fractions. Different sets of criteria with varying dose thresholds for re-planning were investigated. All sets of criteria ensure equivalent target coverage of both CTVs, but vary in the tolerance threshold of the spinal cord. Results: The variations of the D95 and D2 in respect to the planned values ranged from -7% to +3% for both CTVs, and -2% to +6% for the spinal cord. Despite different correction vectors of the three IGRT strategies, the dosimetric differences were small. The number of fractions not requiring re-planning varied between 0% and 11% dependent on the applied IGRT correction strategy. In contrast, this number ranged between 32% and 70% dependent on the dosimetric thresholds, even though these thresholds were only gently modified. Conclusions: The more precise the planned dose needs to be maintained over the treatment course, the more frequently re-planning is required. The influence of different IGRT correction strategies, even though geometrically notable, was found to be of only limited relevance for the re-planning frequency. In contrast, the definition and modification of thresholds for re-planning have a major impact on the re-planning frequency.
引用
收藏
页数:8
相关论文
共 47 条
  • [21] Quantitative Assessment for Timely Adaptive Re-Planning Using Weekly Dose Monitoring for Head and Neck Cancer
    Shang, Q.
    Li, Z.
    Liu, H.
    Greskovich, J.
    Koyfman, S.
    Xia, P.
    MEDICAL PHYSICS, 2014, 41 (06) : 210 - 210
  • [22] A Retrospective Comparison of using Image-guided Radiation Therapy (IGRT) with Three Different Methods: a) No Re-planning, b) Patient-specific Library Planning and c) Instant Re-planning Radiation Therapy (IRRT)
    Merrick, S.
    Wong, J.
    Gao, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S745 - S745
  • [23] IMRT Re-Planning by Adjusting Voxel-Based Weighting Factors for Adaptive Radiotherapy
    Li, N.
    Zarepisheh, M.
    Tian, Z.
    Uribe-Sanchez, A.
    Zhen, X.
    Graves, Y.
    Gautier, Q.
    Zhou, Linghong
    Jia, X.
    Jiang, S.
    MEDICAL PHYSICS, 2012, 39 (06) : 3966 - 3966
  • [24] TOWARDS ADAPTIVE RE-PLANNING OF H/N IMRT PATIENTS: AN AUDIT OF THE CHANGE IN 'NECK' VOLUME DURING TREATMENT.
    Moinuddin, S. A.
    Kilkenny, M.
    Davies, P.
    Rompokos, V.
    Rosenberg, I.
    Royle, G.
    Carnell, D.
    Mendes, R.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S450 - S450
  • [25] Increase of Adaptive Re-Planning Frequency with Using Automated Daily Dose Tracking
    Kainz, K.
    Lim, S.
    Chen, G.
    Li, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E435 - E435
  • [26] Use of knowledge based DVH predictions to enhance automated re-planning strategies in head and neck adaptive radiotherapy
    Cagni, Elisabetta
    Botti, Andrea
    Chendi, Agnese
    Iori, Mauro
    Spezi, Emiliano
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (13):
  • [27] Issues in Image-Guided Radiotherapy (IGRT) and Re-Planning with Megavoltage Cone Beam CT (MVCT)
    Cheng, C.
    Gao, Z.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] Moving From Geometric-Based to Risk-Based Adaptive Re-Planning in Head and Neck Radiotherapy
    Brock, K.
    Gryshkevych, S.
    Rigaud, B.
    Ohrt, A.
    Svensson, S.
    Fuller, C.
    MEDICAL PHYSICS, 2020, 47 (06) : E431 - E431
  • [29] Automated Planning for Fast On-Line CT-Guided Adaptive Re-Planning in IMRT for Prostate Cancer Patients
    Pan, X.
    Zhang, X.
    Li, Y.
    Li, X.
    Wang, X.
    Mohan, R.
    MEDICAL PHYSICS, 2009, 36 (06) : 2538 - +
  • [30] 18F-Fdg-PET-guided Planning and Re-Planning (Adaptive) Radiotherapy in Head and Neck Cancer: Current State of Art
    Farina, Eleonora
    Ferioli, Martina
    Castellucci, Paolo
    Farina, Arianna
    Rambaldi, Giuseppe Zanirato
    Cilla, Savino
    Cammelli, Silvia
    Fanti, Stefano
    Morganti, Alessio G.
    ANTICANCER RESEARCH, 2017, 37 (12) : 6523 - 6532