Absolute Gamma Source Positioning with Position-sensitive Scintillation Detector Arrays

被引:0
|
作者
Wang, Rui [1 ]
Wang, Shi [1 ]
Fan, Peng [2 ,3 ]
Xu, Tianpeng [1 ]
Lyu, Zhenlei [1 ]
Ye, Qing [1 ]
Wu, Zhaoxia [1 ]
Xia, Yan [2 ,3 ]
Liu, Yaqiang [1 ]
Ma, Tianyu [1 ]
机构
[1] Tsinghua Univ, Key Lab Particle & Radiat Imaging, Dept Engn Phys, Minist Educ, Beijing 100084, Peoples R China
[2] China Acad Space Technol, Beijing Inst Spacecraft Environm Engn, Beijing 100094, Peoples R China
[3] Beijing Inst Spacecraft Environm Engn, Sci & Technol Reliabil & Environm Engn Lab, Beijing 100094, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Radioactive sources are widely used in industrial and medical applications. In home-land security, it is important to monitor radioactive source in public areas such as airport to prevent public hazard. Traditional radiation detection devices such as Geiger counter cannot provide position information. Exist imaging devices including Gamma cameras with mechanical collimators, or Compton cameras can only determine directional information of the radioactive sources over the 4 pi angular space, which is not enough for accurate source positioning in the crowded areas with high population density. In this work, we propose a novel method to achieve 3-D imaging capability of the absolute radioactive sources position with position-sensitive scintillator detector arrays. Targeting at application in a typical public places such as airports, we propose a 6-detector imaging system setup. The detector design is based on a pixilated dual-ended GAGG scintillation detector block that has been developed in our lab. The measured photon count distribution of all the six detectors are combined together to form the projection data. A ML-EM algorithm is used reconstruct the source intensity image in Cartesian coordinates. In Monte Carlo simulation, a 511 keV point source was placed at four different positions in the FOV to measure the projection data. Both the positioning accuracy and the FWHM image resolution were calculated from the reconstructed image to evaluate the performance of the proposed imaging method. The reconstructed images converge to desired point-type distribution with certain spread observed in both the simulation and the experimental study. Accurate positioning accuracy is achievable in all cases. In conclusion, the proposed method demonstrates feasibility for absolute positioning of the radioactive sources in 3-D Cartesian space. We believe that it is promisingly useful in public safety applications.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] NEW LINEAR POSITION-SENSITIVE SCINTILLATION DETECTOR FOR NEUTRON POWDER DIFFRACTOMETRY.
    Schaefer, W.
    Jansen, E.
    Elf, F.
    Will, G.
    1600, (17):
  • [42] A Large Area Position-Sensitive Scintillation Neutron Detector For Upgrading SENJU Diffractometer
    Nakamura, T.
    Toh, K.
    Ebine, M.
    Birumachi, A.
    Sakasai, K.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [43] POSITION-SENSITIVE, HIGH-ENERGY GAMMA-RAY DETECTOR
    GILAD, S
    BOWMAN, JD
    COOPER, MD
    HEFFNER, RH
    HOFFMAN, CM
    MOINESTER, MA
    POTTER, JM
    CVERNA, FH
    BAER, HW
    BEVINGTON, PR
    MCNAUGHTON, MW
    NUCLEAR INSTRUMENTS & METHODS, 1977, 144 (02): : 103 - 108
  • [45] Measurements of low dose rates of gamma-rays using position-sensitive plastic scintillation optical fiber detector
    Song, Siwon
    Kim, Jinhong
    Park, Jae Hyung
    Kim, Seunghyeon
    Lim, Taeseob
    Kim, Jin Ho
    Kim, Sin
    Lee, Bongsoo
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (09) : 3398 - 3402
  • [46] POSITION-SENSITIVE LIQUID-XENON DETECTOR FOR GAMMA-RAYS
    GUSHCHIN, EM
    KRUGLOV, AA
    OBODOVSKII, IM
    POKACHALOV, SG
    SHILOV, VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (03) : 561 - 564
  • [47] POSITION-SENSITIVE GAMMA-QUANTUM DETECTOR FOR POSITRON EMISSION TOMOGRAPH
    ABRAMOV, AA
    ALEKSEEVA, EA
    BURACHAS, SF
    VASILCHENKO, VG
    GLOTOV, VI
    GORELOV, AI
    KLIMOV, AI
    MAIOROV, VN
    MARTYNOV, AV
    MELESHKO, EA
    MOROZOV, AG
    MOROZOV, IV
    MYASOEDOV, LV
    OLEINIK, SV
    RYZHIKOV, VD
    RYKALIN, VI
    SELIVANOV, VI
    SINITSYN, IV
    TOROKHOV, VD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1990, 33 (05) : 1054 - 1060
  • [48] GAMMA-RAY POSITION-SENSITIVE COAXIAL GE(LI) DETECTOR
    SHERMAN, IS
    STRAUSS, MG
    NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (01): : 285 - 294
  • [49] POSITION-SENSITIVE LIQUID-XENON DETECTOR FOR gamma RAYS.
    Gushchin, E.M.
    Kruglov, A.A.
    Obodovskii, I.M.
    Pokachalov, S.G.
    Shilov, V.A.
    Instruments and experimental techniques New York, 1982, 25 (3 pt 1): : 561 - 564
  • [50] OPTIMIZATION OF LIGHT YIELD OF SCINTILLATOR FOR POSITION-SENSITIVE GAMMA-DETECTOR
    VOLKOVICH, AG
    LIKSONOV, VI
    LOBANOVSKII, DA
    SMIRNOV, SV
    STEPANOV, VE
    TYURIN, AS
    URUTSKOEV, LI
    FILIPPOV, DV
    CHESNOKOV, AV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1991, 34 (02) : 325 - 327