Front end electronics for a variable field PET camera using the PMT-quadrant-sharing detector array design

被引:0
|
作者
Wong, WH
Hu, GJ
Zhang, N
Uribe, J
Wang, JM
Li, HD
Lu, WZ
Baghaei, H
Yokoyama, S
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This is an electronic design for a PET camera with 8 arrays of position sensitive detectors. Each array has 16 EGO blocks (each block is composed of 49 crystals). The design goals are component and space reduction. Each PMT has its fast amplifier and triggered integrator. Nine flash ADC serve an array of 27 PMT and 784 crystals. The fast signals from one or more PMT clusters are summed. The fast summed signals are thresholded and sent to a programmable logic to determines the probable scintillation zone (4 blocks) and to turn ore the associated 9 PMT integrators. After integration, the logic also drives a set of ultra-fast analog switches to connect the flash ADC set to the PMT integration channels in the scintillation zone. The 9 ADC output (integrated pulses with good photon statistics) are latched and compared. The comparator result determines which block in the zone is firing and the appropriate 4 ADC are selected and bused into a position decoder. The decoder outputs the image-slice address and the crystal address. The circuit is pipelined and driven by a 250 MHz master clock. The maximum event-processing rate for the circuit and a random radiation source is 21 x 10(6)/sec (with 10:1 randomness allowance).
引用
收藏
页码:1320 / 1324
页数:5
相关论文
共 30 条
  • [21] Development and NEMA imaging performance of a lower-cost higher-resolution animal PET-CT using PMT-quadrant-sharing technology
    Wong, Wai-Hoi
    Li, Hongdi
    Zhang, Yuxuan
    Baghaei, Hossain
    Ramirez-Jaramillo, Rocio
    Liu, Shitao
    Wang, Chao
    An, Shaohui
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [22] Elongated position sensitive block detector design using the PMT quadrant sharing configuration and asymmetric light partition
    Univ of Texas M.D. Anderson Cancer, Cent, Houston, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (1204-1207):
  • [23] Signal characteristics of individual, crystals in a high resolution BGO detector design using PMT-quadrant sharing
    Uribe, J
    Li, HD
    Liu, YQ
    Xing, T
    Baghaei, H
    Wang, Y
    Farrell, R
    Wong, WH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 926 - 930
  • [24] New 9x9 and 10x10 BGO block detector for human PET using PMT quadrant sharing design
    Liu, Shitao
    Liu, Jiguo
    Zhang, Yuxuan
    Kim, Soonseok
    Li, Hongdi
    Ramirez, Rocio
    Wang, Yu
    Baghaei, Hossain
    Wong, Wai-Hoi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) : 457 - 462
  • [25] An elongated position sensitive block detector design using the PMT quadrant-sharing configuration and asymmetric light partition
    Wong, WH
    Yokoyama, S
    Uribe, J
    Baghaei, H
    Li, HD
    Wang, JM
    Zhang, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 542 - 545
  • [26] Construction and imaging characteristics of a convertible field-of-view PET camera using the low cost high resolution photomultiplier-quadrant-sharing detector design.
    Wong, WH
    Uribe, J
    Li, H
    Baghaei, H
    Zhang, N
    Yokoyama, S
    Wang, J
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 93P - 94P
  • [27] Inexpensive position sensitive detector block for dedicated PET cameras using 40-mm diameter PMT in quadrant sharing configuration
    Uribe, J
    Aykac, M
    Baghaei, H
    Li, HD
    Wang, Y
    Liu, YQ
    Wong, V
    Xing, T
    Ramirez, R
    Wong, WH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 367 - 372
  • [28] THEORETICAL DECODING RESOLUTION LIMITS OF A PET DETECTOR DESIGN USING QUADRANT SHARING PHOTOMULTIPLIERS AND CROSS-COUPLED BGO
    WONG, WH
    HICKS, K
    NGUYEN, D
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P102 - P102
  • [29] The 40 CCDs of the MegaCam wide-field camera: design and first tests of the front-end electronics.
    de Kat, J
    Abbon, P
    OPTICAL AND IR TELESCOPE INSTRUMENTATION AND DETECTORS, PTS 1 AND 2, 2000, 4008 : 427 - 438
  • [30] Design on Front-end Readout ASIC with Variable Gain and Wide Dynamic Range for 3D Si PIN Array Thermal Neutron Detector; [基于3D Si PIN阵列热中子探测器的变增益宽动态前端读出电子学设计]
    Han N.
    Li L.
    Li X.
    Liu S.
    Ma Y.
    Xiong Y.
    Li B.
    Zhang G.
    Fiorini C.E.
    Chen W.
    Liu, Shuhuan, 2021, Atomic Energy Press (55): : 2237 - 2250