HEART:: an automated beat-to-beat cardiovascular analysis package using Matlab®

被引:40
|
作者
Schroeder, MJ [1 ]
Perreault, B
Ewert, DL
Koenig, SC
机构
[1] N Dakota State Univ, Dept Elect & Comp Engn, Cardiovasc Res Lab, Fargo, ND 58105 USA
[2] Univ Louisville, Jewish Hosp Heart & Lung Inst, Dept Surg, Louisville, KY 40202 USA
关键词
data acquisition; data analysis; beat to beat; hemodynamics; cardiovascular; computer software package; Matlab((R));
D O I
10.1016/S0010-4825(03)00087-8
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A computer program is described for beat-to-beat analysis of cardiovascular parameters from high-fidelity pressure and flow waveforms. The Hemodynamic Estimation and Analysis Research Tool (HEART) is a post-processing analysis software package developed in Matlab(R) that enables scientists and clinicians to document, load, view, calibrate, and analyze experimental data that have been digitally saved in ascii or binary format. Analysis routines include traditional hemodynamic parameter estimates as well as more sophisticated analyses such as lumped arterial model parameter estimation and vascular impedance frequency spectra. Cardiovascular parameter values of all analyzed beats can be viewed and statistically analyzed. An attractive feature of the HEART program is the ability to analyze data with visual quality assurance throughout the process, thus establishing a framework toward which Good Laboratory Practice (GLP) compliance can be obtained. Additionally, the development of HEART on the Matlab(R) platform provides users with the flexibility to adapt or create study specific analysis files according to their specific needs. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:371 / 388
页数:18
相关论文
共 50 条
  • [41] HEART RATE METER WITH DIGITAL TIMING AND LINEAR BEAT-TO-BEAT READOUT
    LUDWIG, H
    NG, YK
    MEDICAL & BIOLOGICAL ENGINEERING, 1967, 5 (06): : 615 - &
  • [42] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    David S. Goldstein
    William P. Cheshire
    Clinical Autonomic Research, 2017, 27 : 361 - 367
  • [43] A beat-to-beat estimation of the contractile state of the heart by means of genetic algorithms
    Grigioni, M
    Daniele, C
    Morbiducci, U
    Di Benedetto, G
    D'Avenio, G
    Barbaro, V
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 873 - 876
  • [44] Ibutilide increases beat-to-beat repolarization lability in patients with heart disease
    Angkeow, P
    Calkins, H
    Marbán, E
    Tomaselli, GF
    Berger, RD
    CIRCULATION, 2001, 104 (17) : 381 - 381
  • [45] Beat-to-beat blood pressure and heart rate responses to the Valsalva maneuver
    Goldstein, David S.
    Cheshire, William P., Jr.
    CLINICAL AUTONOMIC RESEARCH, 2017, 27 (06) : 361 - 367
  • [46] FETAL HEART-RATE BEAT-TO-BEAT VARIABILITY IN UNCOMPLICATED LABOR
    ZIMMER, EZ
    DIVON, MY
    VADASZ, A
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 1988, 25 (02) : 80 - 82
  • [47] Effect of posture and isoproterenol on beat-to-beat heart rate and QT variability
    Yeragani, VK
    Pohl, R
    Jampala, VC
    Balon, R
    Kay, J
    Igel, G
    NEUROPSYCHOBIOLOGY, 2000, 41 (03) : 113 - 123
  • [48] Intermittently decreased beat-to-beat variability in congestive heart failure - Reply
    Costa, M
    Goldberger, AL
    Peng, CK
    PHYSICAL REVIEW LETTERS, 2003, 91 (11)
  • [49] MICROCOMPUTER-BASED MEASUREMENT OF BEAT-TO-BEAT INTERVALS AND ANALYSIS OF HEART-RATE-VARIABILITY
    MORGUET, A
    SPRINGER, HJ
    MEDICAL PROGRESS THROUGH TECHNOLOGY, 1981, 8 (02) : 77 - 82
  • [50] An Effective Algorithm for Beat-to-Beat Heart Rate Monitoring from Ballistocardiograms
    Liang, Jingxian
    Huang, Jialin
    Mu, Liwei
    Yu, Baoxian
    Chen, Pengbin
    Pang, Zhiqiang
    Nie, Ruihua
    Zhang, Han
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (03) : 633 - 640