Quantitative cartilage imaging using spectral photon-counting detector based computed tomography

被引:1
|
作者
Endran, Kishore Raj [1 ]
Tao, Shengzhen [1 ]
Benike, Amy [1 ]
Leng, Shuai [1 ]
McCollough, Cynthia [1 ]
机构
[1] Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA
关键词
Photon-counting detectors; computed tomography; multi-energy; ultra-high resolution; glycosaminoglycans; trypsin digestion; MRI;
D O I
10.1117/12.2512627
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Glycosaminoglycans (GAG) in the extracellular matrix of the articular cartilage are biomarkers of cartilage health. Loss of GAG has been associated with early stage osteoarthritis, with zonal depletion of intra-articular GAG levels occurring prior to cartilage degeneration. Detecting this biochemical change in articular cartilage may facilitate early diagnosis of osteoarthritis. GAG is negatively-charged and repels anionic contrast media. Increased uptake of anionic contrast agents could be correlated with depleted GAG levels in the cartilage. Photon-counting detector (PCD) based computed tomography (CT) offers high-resolution imaging and x-ray energy discrimination capabilities. This allows delineation of finer anatomical structures, and the generation of quantitative material maps using energy-resolved CT data. In this study, we demonstrate quantitative GAG imaging in porcine cartilage using a research whole-body PCD-CT system and an anionic contrast agent. Hind knee joints were harvested from euthanized pigs. GAG depletion mimicking early-OA was induced using trypsin treatment. Both the control group and the trypsin-treated group were incubated in an anionic gadolinium contrast prior to PCD-CT scanning. The specimens were scanned at ultra-high resolution using the PCD-CT system at 120kV, 330mAs, and [25, 51] keV energy thresholds. An image-domain material decomposition was employed to generate the mass density map for gadolinium in cartilage using energy-resolved PCD-CT data. The results showed significantly higher gadolinium uptake (p < 0.0001) in the trypsin-treated specimens, compared to the control specimens. We demonstrated high-resolution ex vivo cartilage imaging using PCD-CT to quantify gadolinium uptake in articular cartilage as an inverse marker of GAG.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] ChromAIX: Fast photon-counting ASIC for Spectral Computed Tomography
    Steadman, Roger
    Herrmann, Christoph
    Muelhens, Oliver
    Maeding, Dale G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S211 - S215
  • [22] Spectral Photon-Counting Computed Tomography for Classification of Liver Lesions
    Muenzel, D.
    Daer, H.
    Proksa, R.
    Fingerle, A.
    Kopp, F.
    Douek, P.
    Herzen, J.
    Pfeiffer, F.
    Rummeny, E.
    Noel, P. B.
    MEDICAL PHYSICS, 2017, 44 (06) : 3233 - 3233
  • [23] Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography A Systematic Phantom and Patient Study
    Sartoretti, Thomas
    Mergen, Victor
    Higashigaito, Kai
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    INVESTIGATIVE RADIOLOGY, 2022, 57 (07) : 488 - 493
  • [24] Dedicated Breast Computed Tomography With a Photon-Counting Detector Initial Results of Clinical In Vivo Imaging
    Berger, Nicole
    Marcon, Magda
    Saltybaeva, Natalia
    Kalender, Willi A.
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2019, 54 (07) : 409 - 418
  • [25] Photon-counting computed tomography in radiology
    Algin, Oktay
    Tokgoz, Nazime
    Cademartiri, Filippo
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e433 - e442
  • [26] Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints
    Quintiens, Jilmen
    van Lenthe, G. Harry
    CURRENT OSTEOPOROSIS REPORTS, 2024, 22 (04) : 387 - 395
  • [27] Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1999 - 2022
  • [28] Optimization of beam quality for photon-counting spectral computed tomography in head imaging: simulation study
    Chen, Han
    Xu, Cheng
    Persson, Mats
    Danielsson, Mats
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (04)
  • [29] Evaluation of models of spectral distortions in photon-counting detectors for computed tomography
    Cammin, Jochen
    Kappler, Steffen
    Weidinger, Thomas
    Taguchi, Katsuyuki
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (02)
  • [30] Effects of calibration methods on quantitative material decomposition in photon-counting spectral computed tomography using a maximum a posteriori estimator
    Curtis, Tyler E.
    Roeder, Ryan K.
    MEDICAL PHYSICS, 2017, 44 (10) : 5187 - 5197