Cardiorenal 23Na MRI at 7.0 Tesla using a 4/4 channel 1H/23Na RF antenna array

被引:17
|
作者
Boehmert, Laura [1 ]
Kuehne, Andre [2 ]
Waiczies, Helmar [2 ]
Wenz, Daniel [1 ]
Eigentler, Thomas Wilhelm [1 ]
Funk, Stephanie [3 ]
von Knobelsdorff-Brenkenhoff, Florian [3 ,4 ]
Schulz-Menger, Jeanette [3 ,5 ]
Nagel, Armin M. [6 ,7 ,8 ]
Seeliger, Erdmann [9 ]
Niendorf, Thoralf [1 ,2 ,5 ,10 ]
机构
[1] Helmholtz Assoc, Max Delbruck Ctr Mol Med, BUFF, Berlin, Germany
[2] MRI TOOLS GmbH, Berlin, Germany
[3] Charite Med Fac & Max Delbruck Ctr Mol Med Helios, Expt & Clin Res Ctr, Working Grp Cardiovasc Magnet Resonance, Berlin, Germany
[4] Ludwig Maximilians Univ Munchen, Acad Teaching Hosp, Clin Agatharied, Dept Cardiol, Hausham, Germany
[5] DZHK German Ctr Cardiovasc Res, Partner Site Berlin, Berlin, Germany
[6] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, Erlangen, Germany
[7] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
[8] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Erlangen, Inst Med Phys, Erlangen, Germany
[9] Charite, Inst Vegetat Physiol, Berlin, Germany
[10] Charite Med Fac & Max Delbruck Ctr Mol Med, Expt & Clin Res Ctr, Berlin, Germany
关键词
cardiac MRI; cardiorenal syndrome; MRI; renal MRI; RF coil; sodium; SODIUM MRI; 7; T; HUMAN HEART; MYOCARDIAL-INFARCTION; CARDIOVASCULAR MRI; HUMAN KIDNEYS; TIME-COURSE; COIL; DESIGN; CARTILAGE;
D O I
10.1002/mrm.27880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Cardiorenal syndrome describes disorders of the heart and the kidneys in which a dysfunction of 1 organ induces a dysfunction in the other. This work describes the design, evaluation, and application of a 4/4-channel hydrogen-1/sodium (H-1/Na-23) RF array tailored for cardiorenal MRI at 7.0 Tesla (T) for a better physiometabolic understanding of cardiorenal syndrome. Methods The dual-frequency RF array is composed of a planar posterior section and a modestly curved anterior section, each section consisting of 2 loop elements tailored for Na-23 MR and 2 loopole-type elements customized for H-1 MR. Numerical electromagnetic field and specific absorption rate simulations were carried out. Transmission field (B1+) uniformity was optimized and benchmarked against electromagnetic field simulations. An in vivo feasibility study was performed. Results The proposed array exhibits sufficient RF characteristics, B1+ homogeneity, and penetration depth to perform Na-23 MRI of the heart and kidney at 7.0 T. The mean B1+ field for sodium in the heart is 7.7 +/- 0.8 mu T/root kW and in the kidney is 6.9 +/- 2.3 mu T/root kW. The suitability of the RF array for Na-23 MRI was demonstrated in healthy subjects (acquisition time for Na-23 MRI: 18 min; nominal isotropic spatial resolution: 5 mm [kidney] and 6 mm [heart]). Conclusion This work provides encouragement for further explorations into densely packed multichannel transceiver arrays tailored for Na-23 MRI of the heart and kidney. Equipped with this technology, the ability to probe sodium concentration in the heart and kidney in vivo using Na-23 MRI stands to make a critical contribution to deciphering the complex interactions between both organs.
引用
收藏
页码:2343 / 2356
页数:14
相关论文
共 50 条
  • [41] 3D 23Na MRI of human skeletal muscle at 7 Tesla: initial experience
    Gregory Chang
    Ligong Wang
    Mark E. Schweitzer
    Ravinder R. Regatte
    European Radiology, 2010, 20 : 2039 - 2046
  • [42] 3D 23Na MRI of human skeletal muscle at 7 Tesla: initial experience
    Chang, Gregory
    Wang, Ligong
    Schweitzer, Mark E.
    Regatte, Ravinder R.
    EUROPEAN RADIOLOGY, 2010, 20 (08) : 2039 - 2046
  • [43] Corrections of myocardial tissue sodium concentration measurements in human cardiac 23Na MRI at 7 Tesla
    Lott, Johanna
    Platt, Tanja
    Niesporek, Sebastian C.
    Paech, Daniel
    Behl, Nicolas G. R.
    Niendorf, Thoralf
    Bachert, Peter
    Ladd, Mark E.
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 159 - 173
  • [44] Motion-corrected 23Na MRI of the human brain using interleaved 1H 3D navigator images
    Wilferth, Tobias
    Mueller, Max
    Gast, Lena, V
    Ruck, Laurent
    Meyerspeer, Martin
    Kolkovsky, Alfredo L. Lopez
    Uder, Michael
    Doerfler, Arnd
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) : 309 - 321
  • [45] Feasibility study of a double resonant 8-channel 1H/ 8-channel 23Na receive-only head coil at 3 Tesla
    Malzacher, Matthias
    Chacon-Caldera, Jorge
    Paschke, Nadia
    Schad, Lothar R.
    MAGNETIC RESONANCE IMAGING, 2019, 59 : 97 - 104
  • [46] Double tuned 23Na 1H nuclear magnetic resonance birdcage for application on mice in vivo
    Lanz, T
    Ruff, J
    Weisser, A
    Haase, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (05): : 2508 - 2510
  • [47] 23Na MRI of human skeletal muscle using long inversion recovery pulses
    Wilferth, Tobias
    Gast, Lena V.
    Stobbe, Robert W.
    Beaulieu, Christian
    Hensel, Bernhard
    Uder, Michael
    Nagel, Armin M.
    MAGNETIC RESONANCE IMAGING, 2019, 63 : 280 - 290
  • [48] Time-efficient interleaved human 23Na and 1H data acquisition at 7 T
    de Bruin, Paul W.
    Koken, Peter
    Versluis, Maarten J.
    Aussenhofer, Sebastian A.
    Meulenbelt, Ingrid
    Bornert, Peter
    Webb, Andrew G.
    NMR IN BIOMEDICINE, 2015, 28 (10) : 1228 - 1235
  • [49] Application of 23Na MRI to monitor chemotherapeutic response in RIF-1 tumors
    Babsky, AM
    Hekmatyar, SK
    Zhang, H
    Solomon, JL
    Bansal, N
    NEOPLASIA, 2005, 7 (07): : 658 - 666
  • [50] Numerical and Workbench Design of 2.35 T Double-Tuned (1H/23Na) Nested RF Birdcage Coils Suitable for Animal Size MRI
    Fantasia, Marco
    Galante, Angelo
    Maggiorelli, Francesca
    Retico, Alessandra
    Fontana, Nunzia
    Monorchio, Agostino
    Alecci, Marcello
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3175 - 3186