Voltammetric determination of caffeine by using gold nanoparticle-glassy carbon paste composite electrode

被引:25
|
作者
Oren, Tugba [1 ]
Anik, Ulku [1 ]
机构
[1] Mugla Sitki Kocman Univ, Fac Sci, Dept Chem, TR-48000 Kotekli Mugla, Turkey
关键词
Caffeine; AuNP; Composite electrode; Glassy carbon paste electrode; DOPED DIAMOND ELECTRODE; CHEMICALLY-MODIFIED ELECTRODE; ELECTROCHEMICAL SENSOR; PHARMACEUTICAL FORMULATIONS; BEVERAGE SAMPLES; ASCORBIC-ACID; REAL SAMPLES; SOL-GEL; COFFEE; GRAPHENE;
D O I
10.1016/j.measurement.2017.04.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the present study, simple and sensitive voltammetric determination of caffeine was carried out by using a gold nanoparticle-glassy carbon paste composite electrode (AuNP-GCPE) in 3.2 mM H2SO4 (pH 2.5). The effects of supporting electrolyte, pH and AuNP amount on caffeine peak current were investigated. After the optimization of experimental parameters, analytical characteristics of AuNP-GCPE were examined and two linear ranges were obtained between 25-150 mu M and 200-1000 mu M with limit of detection values of 0.96 mu M and 4.90 mu M, respectively. Relative standard deviation for 50 mu M caffeine was also calculated as 7.52% (n = 3). In order to evaluate the analytical performance of AuNP-GCPE, caffeine contents of various brands of cola samples were measured and compared with the results obtained by UV-Vis spectrometer. The obtained results by using the proposed composite electrode are in accordance with the caffeine contents that manufacturers claimed compared to UV-Vis. This composite electrode which utilizes the catalytic effect of AuNP with the simple preparation of GCPE, offers a fast and sensitive determination of caffeine in beverages as a practical application. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
  • [21] Voltammetric determination of selected aminoquinolines using carbon paste electrode
    Zima, J
    Stoica, AI
    Zítová, A
    Barek, J
    ELECTROANALYSIS, 2006, 18 (02) : 158 - 162
  • [22] Voltammetric determination of bisphenol A using modified carbon paste electrode
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [23] Voltammetric determination of lactate dehydrogenase using a carbon paste electrode
    Tarmure, C
    Sandulescu, R
    Ionescu, C
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (02) : 355 - 361
  • [24] Voltammetric Oxidation and Determination of Atenolol Using a Carbon Paste Electrode
    Patil, Roopa H.
    Hegde, Rajesh N.
    Nandibewoor, S. T.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (23) : 10206 - 10210
  • [25] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Beigmoradi, Fariba
    Beitollahi, Hadi
    SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY, 2024, 60 (01) : 15 - 23
  • [26] Voltammetric determination of necrodil sodium using glassy carbon electrode
    Rosa, TF
    Saczk, AA
    Zanoni, MVB
    Stradiotto, NR
    ECLETICA QUIMICA, 2003, 28 (02): : 63 - 68
  • [27] Voltammetric Determination of Nitrite Using Modified Glassy Carbon Electrode
    Surface Engineering and Applied Electrochemistry, 2024, 60 : 15 - 23
  • [28] Electrochemistry of robust gold nanoparticle-glassy carbon hybrids generated using a patternable photochemical approach
    Gobbo, Pierangelo
    Ghiassian, Sara
    Hesari, Mahdi
    Stamplecoskie, Kevin G.
    Kazemi-Zanjani, Nastaran
    Lagugne-Labarthet, Francois
    Workentin, Mark S.
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (45) : 23971 - 23980
  • [30] VOLTAMMETRIC DETERMINATION OF GOLD WITH A RHODAMINE B-MODIFIED CARBON PASTE ELECTRODE
    KOLBL, G
    KALCHER, K
    VOULGAROPOULOS, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2): : 83 - 86