A multidimensional liquid chromatography-tandem mass spectrometry platform to improve protein identification in high-throughput shotgun proteomics

被引:15
|
作者
Capriotti, Anna Laura [1 ]
Cavaliere, Chiara [1 ]
Cavazzini, Alberto [2 ]
Gasparrini, Francesco [3 ]
Pierri, Giuseppe [3 ]
Piovesana, Susy [1 ]
Lagana, Aldo [1 ]
机构
[1] Sapienza Univ Rome, Dept Chem, Ple Aldo Moro 5, I-00185 Rome, Italy
[2] Univ Ferrara, Dept Chem & Pharmaceut Sci, Via L Borsari 46, Ferrara, Italy
[3] Sapienza Univ Rome, Dept Drug Chem & Technol, Ple Aldo Moro 5, Rome, Italy
关键词
NanoHPLC-MS/MS; Multidimensional chromatography; Shotgun proteomics; Monolithic trapping column; Peptide fractionation; STATIONARY-PHASE; HYDROPHILIC INTERACTION; MONOLITHIC COLUMNS; PEPTIDE SEPARATION; PEAK-CAPACITY; EXCHANGE; COMPLEX; SAMPLES; MS/MS; DEEP;
D O I
10.1016/j.chroma.2017.03.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new on-line multidimensional system for sequential trapping and individual elution and separation of peptides based on their molecular weight is described. By sequentially using two chemically different trapping columns, a polymethacrylate monolith and a packed C18 one, peptides from complex samples can be on-line trapped and divided into two fractions, containing respectively mainly medium-large peptides and smaller peptides. Then, by means of two switching valves working in parallel, the two fractions were individually separated by reversed phase chromatography. The whole gradient consisted of two subgradients, with the first one dedicated to the separation of smaller peptides and the second one to the separation of larger peptides. Such configuration allowed to identify up to 1476 proteins in a standard E. coli tryptic digest, with improved performance, increased average sequence coverage and reduced single unique peptide identifications compared to a conventional shotgun proteomics configuration comprising only the C18 trapping column and the analytical column. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:176 / 182
页数:7
相关论文
共 50 条
  • [31] Extractionless and sensitive method for high-throughput quantitation of cetirizine in human plasma samples by liquid chromatography-tandem mass spectrometry
    de Jager, AD
    Hundt, HKL
    Swart, KJ
    Hundt, AF
    Els, J
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (02): : 113 - 118
  • [32] Harmonization of Liquid Chromatography-Tandem Mass Spectrometry Protein Assays
    Rockwood, Alan L.
    Lowenthal, Mark S.
    Bystrom, Cory
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 499 - +
  • [33] A simplified device for protein identification by microcapillary gradient liquid chromatography-tandem mass spectrometry
    McGinley, MD
    Davis, MT
    Robinson, JH
    Spahr, CS
    Bures, EJ
    Beierle, J
    Mort, J
    Patterson, SD
    ELECTROPHORESIS, 2000, 21 (09) : 1678 - 1684
  • [34] Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses
    Rudnick, Paul A.
    Clauser, Karl R.
    Kilpatrick, Lisa E.
    Tchekhovskoi, Dmitrii V.
    Neta, Pedatsur
    Blonder, Niksa
    Billheimer, Dean D.
    Blackman, Ronald K.
    Bunk, David M.
    Cardasis, Helene L.
    Ham, Amy-Joan L.
    Jaffe, Jacob D.
    Kinsinger, Christopher R.
    Mesri, Mehdi
    Neubert, Thomas A.
    Schilling, Birgit
    Tabb, David L.
    Tegeler, Tony J.
    Vega-Montoto, Lorenzo
    Variyath, Asokan Mulayath
    Wang, Mu
    Wang, Pei
    Whiteaker, Jeffrey R.
    Zimmerman, Lisa J.
    Carr, Steven A.
    Fisher, Susan J.
    Gibson, Bradford W.
    Paulovich, Amanda G.
    Regnier, Fred E.
    Rodriguez, Henry
    Spiegelman, Cliff
    Tempst, Paul
    Liebler, Daniel C.
    Stein, Stephen E.
    MOLECULAR & CELLULAR PROTEOMICS, 2010, 9 (02) : 225 - 241
  • [35] Proteomics of human glomerulonephritis by laser microdissection and liquid chromatography-tandem mass spectrometry
    Kawata, Naoto
    Kang, Dedong
    Aiuchi, Toshihiro
    Obama, Takashi
    Yoshitake, Osamu
    Shibata, Takanori
    Takimoto, Masafumi
    Itabe, Hiroyuki
    Honda, Kazuho
    NEPHROLOGY, 2020, 25 (04) : 351 - 359
  • [36] Rapid determination of ketamine in urine by liquid chromatography-tandem mass spectrometry for a high throughput laboratory
    Cheng, JYK
    Mok, VKK
    FORENSIC SCIENCE INTERNATIONAL, 2004, 142 (01) : 9 - 15
  • [37] Protein Probability Model for High-Throughput Protein Identification by Mass Spectrometry-Based Proteomics
    Prieto, Gorka
    Vazquez, Jesus
    JOURNAL OF PROTEOME RESEARCH, 2020, 19 (03) : 1285 - 1297
  • [38] A high-throughput bioinformatics platform for mass spectrometry-based proteomics
    Topaloglou, Thodoros
    Dharsee, Moyez
    Ewing, Rob M.
    Bukhman, Yury
    DATA INTEGRATION IN THE LIFE SCIENCES, PROCEEDINGS, 2007, 4544 : 71 - +
  • [39] A Protein Suspension-Trapping Sample Preparation for Tear Proteomics by Liquid Chromatography-Tandem Mass Spectrometry
    Tse, Jimmy Sung-Hei
    Sze, Ying-Hon
    Cheung, Jimmy Ka-Wai
    Li, King -Kit
    Lam, Thomas Chuen
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (202):
  • [40] Separation and identification of the impurities in monosialotetrahexosylgangliosides by high performance liquid chromatography-tandem mass spectrometry
    Wang Hua
    Xu Yuan
    Liang Feng
    Qi Yanxia
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 29 - 33