On Compensating Synchronization Errors in Two-Terminal Based Fault Location Approaches

被引:0
|
作者
Gama, Jessica R. [1 ]
Lopes, Felipe V. [1 ]
机构
[1] Univ Brasilia, Dept Elect Engn, Brasilia, DF, Brazil
关键词
Fault location; synchronization angle; transmission lines;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two-terminal fault location methods have been increasingly used by utilities since they overcome limitations of single-ended approaches. Most two terminal fault location algorithms found in the literature require measurements to be synchronized, what has been reported as the main problem of these approaches. This paper demonstrates the application of a method able to correct synchronization errors in phasor-based fault location procedures that originally require the data to be synchronized. In order to illustrate its performance, a well known two-terminal fault location algorithm based on synchronized data is taken into account. Compared with other works, the method is simpler and does not require iterative processes. Fault simulations using the Alternative Transients Program (ATP) were carried out to analyze the algorithm performance. The obtained results show that traditional fault location methods based on two-terminal synchronized data may be used without a common time reference, provided that the synchronization error is properly compensated prior to the final fault location estimation.
引用
收藏
页码:46 / 49
页数:4
相关论文
共 50 条
  • [31] Research on adaptability to measurement error for several two-terminal fault location algorithms
    Li, Yong-Jian
    Huang, Shao-Ping
    Tang, Jian-Dong
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (14): : 134 - 139
  • [32] Using of current differential protection signals for fault location on two-terminal line
    Rosolowski, Eugeniusz
    Izykowski, Jan
    Saha, Murari M.
    PRZEGLAD ELEKTROTECHNICZNY, 2008, 84 (05): : 9 - 13
  • [33] An Unsynchronized Measurements Correction Method for Two-Terminal Fault-Location Problems
    Yu, Chi-Shan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) : 1325 - 1333
  • [34] Novel time-domain fault location algorithm by two-terminal currents
    Gao, Shuping
    Song, Guobing
    Jiao, Zaibing
    Suonan, Jiale
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (04): : 101 - 105
  • [35] A new two-terminal numerical algorithm for fault location, distance protection, and arcing fault recognition
    Lee, C. J.
    Park, J. B.
    Shin, J. R.
    Radojevie, Z. M.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (03) : 1460 - 1462
  • [36] A two-terminal fault location method for gas switch prefire in linear transformer driver
    Wan, Zhenbo
    Ding, Weidong
    Sun, Fengju
    Jiang, Xiaofeng
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01):
  • [37] An Accurate Fault Location Algorithm for Two-Terminal Transmission Lines Combined with Parameter Estimation
    Che, Renfei
    Liang, Jun
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 1953 - 1956
  • [38] An improved two-terminal numerical algorithm for fault location estimation considering shunt capacitance
    Kim, H. H.
    Lee, C. J.
    Radojevic, Z. M.
    Park, J. B.
    Shin, J. R.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 2558 - +
  • [39] New method of fault location on double-circuit two-terminal transmission lines
    Mazon, AJ
    Minambres, JF
    Zorrozua, MA
    Zamora, I
    AlvarezIsasi, R
    ELECTRIC POWER SYSTEMS RESEARCH, 1995, 35 (03) : 213 - 219
  • [40] Two-terminal Asynchronous Fault Location Method for MMC-HVDC Transmission Line
    Yang Y.
    Huang C.
    Jiang Y.
    Liu P.
    Tang T.
    Huang, Chun (yellowpure@hotmail.com), 2018, Automation of Electric Power Systems Press (42): : 148 - 154