On Compensating Synchronization Errors in Two-Terminal Based Fault Location Approaches

被引:0
|
作者
Gama, Jessica R. [1 ]
Lopes, Felipe V. [1 ]
机构
[1] Univ Brasilia, Dept Elect Engn, Brasilia, DF, Brazil
关键词
Fault location; synchronization angle; transmission lines;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Two-terminal fault location methods have been increasingly used by utilities since they overcome limitations of single-ended approaches. Most two terminal fault location algorithms found in the literature require measurements to be synchronized, what has been reported as the main problem of these approaches. This paper demonstrates the application of a method able to correct synchronization errors in phasor-based fault location procedures that originally require the data to be synchronized. In order to illustrate its performance, a well known two-terminal fault location algorithm based on synchronized data is taken into account. Compared with other works, the method is simpler and does not require iterative processes. Fault simulations using the Alternative Transients Program (ATP) were carried out to analyze the algorithm performance. The obtained results show that traditional fault location methods based on two-terminal synchronized data may be used without a common time reference, provided that the synchronization error is properly compensated prior to the final fault location estimation.
引用
收藏
页码:46 / 49
页数:4
相关论文
共 50 条
  • [1] Fault Data Synchronization Using Wavelet for Improving Two-terminal Fault Location Algorithm
    Threevithayanon, Wutthikorn
    Hoonchareon, Naebboon
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [2] Fault location on two-terminal transmission lines based on voltages
    Zamora, I
    Minambres, JF
    Mazon, AJ
    ALvarezIsasi, R
    Lazaro, J
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (01) : 1 - 6
  • [3] A two-terminal fault location approach based on unsynchronized phasors
    Dalcastagne, Andre Luis
    Noceti Filho, Sidnei
    Zurn, Hans Helmut
    Seara, Rui
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 2624 - 2630
  • [4] Fault location on two-terminal transmission lines based on voltages
    Basque Country Univ, Bilbao, Spain
    IEE Proc Gener Transm Distrib, 1 (1-6):
  • [5] Unsynchronized two-terminal fault location estimation
    Novosel, D
    Hart, DG
    Udren, E
    Garitty, J
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (01) : 130 - 138
  • [6] Transmission line fault location using two-terminal data without time synchronization
    Silveira, Eduardo G.
    Pereira, Clever
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (01) : 498 - 499
  • [7] A novel method for fault location based on two-terminal unsynchronized data
    Li, Xun
    Gong, Qingwu
    Ming, Ruiqing
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [8] The cable two-terminal fault location algorithm based on EMD and WVD
    Liu, Yang
    Cao, Yundong
    Hou, Chunguang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (16): : 4086 - 4093
  • [9] Two-Terminal Fault Location on Unsymmetrical Transmission Lines
    Schulze, Roberto
    Schegner, Peter
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [10] Fault location of two-terminal transmission lines with a small fault resistance
    Wu, JK
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 714 - 721