Treatment of Vagus Nerve Stimulator Pocket Infection without Removal of the Hardware

被引:0
|
作者
Blaha, Martin [1 ]
Tichy, Michal [1 ]
机构
[1] Charles Univ Prague, Med Fac 2, Univ Hosp Motol, Dept Neurosurg, Prague, Czech Republic
来源
EPILEPSI | 2021年 / 27卷 / 01期
关键词
Biofilms; epilepsy; epilepsy surgery; infection; rifampicin; vagus nerve stimulation; SURGICAL TECHNIQUE; DEVICE INFECTIONS; PARTIAL SEIZURES; MANAGEMENT; EPILEPSY; COMPLICATIONS; IMPLANTATION; EXPERIENCE; EFFICACY; SAFETY;
D O I
10.14744/epilepsi.2020.48344
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The management of postoperative pocket infections after vagus nerve stimulator implantation is challenging. Most patients present within four weeks after the implantation of the device and Staphylococcus aureus is the most common infecting agent. Standard medical practice involves the complete hardware removal and antibiotics to achieve long-term cure, with the subsequent reimplantation of the device. Attempts to treat these infections without the removal of the hardware led to high infection recurrence rates because of the formation of staphylococcal biofilms on the device. We present a case of vagus nerve stimulator infection treated successfully with a single surgical debridement of the infected wound and six weeks of antibiotic treatment, but without removing the hardware.
引用
收藏
页码:62 / 65
页数:4
相关论文
共 50 条
  • [41] VAGUS NERVE STIMULATOR BATTERY REPLACEMENT: WHEN IS THE RIGHT TIME?
    Lee, Joseph K.
    Sanossian, N.
    Heck, C.
    Kalayjian, L.
    EPILEPSIA, 2009, 50 : 139 - 140
  • [42] Intraoperative methods for confirmation of correct placement of the vagus nerve stimulator
    Vaughn, BV
    Bernard, E
    Lannon, S
    Mann, B
    D'Cruz, OF
    Shockley, W
    Passanante, A
    EPILEPTIC DISORDERS, 2001, 3 (02) : 75 - 77
  • [43] Effect of vagus nerve stimulator magnet on programmable shunt settings
    Jandial, R
    Aryan, HE
    Hughes, SA
    Levy, ML
    NEUROSURGERY, 2004, 55 (03) : 627 - 629
  • [44] Treatment of vagus nerve stimulator-induced sleep-disordered breathing: A case series
    Oh, Daniel M.
    Johnson, Jacklyn
    Shah, Bankim
    Bhat, Sushanth
    Nuoman, Rolla
    Ming, Xue
    EPILEPSY & BEHAVIOR REPORTS, 2019, 12
  • [45] Safety and tolerability of early postoperative vagus nerve stimulator activation
    Labar, DR
    Hosain, S
    Nikolov, B
    Fraser, R
    Pulver, M
    Lazar, L
    Li, M
    Harden, C
    EPILEPSIA, 1999, 40 : 216 - 216
  • [46] MRI of the brain is safe in patients implanted with the vagus nerve stimulator
    Benbadis, SR
    Nyhenhuis, J
    Tatum, WO
    Murtagh, FR
    Gieron, M
    Vale, FL
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2001, 10 (07): : 512 - 515
  • [47] A new surgical approach for implantation of a vagus nerve stimulator lead
    Liebman, KM
    EPILEPSIA, 1999, 40 : 205 - 205
  • [48] Robotic Radiosurgery and a Vagus Nerve Stimulator: An in Vitro Feasibility Study
    Blamek, S. C.
    Stapor-Fudzinska, M.
    Larysz, D.
    Niewiadomska, B.
    Bekman, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E639 - E639
  • [49] Transient atrial fibrillation after the implantation of a vagus nerve stimulator
    Srinivasan, B
    Awasthi, A
    EPILEPSIA, 2004, 45 (12) : 1645 - 1645
  • [50] Use of Vagus Nerve Stimulator on Children With Primary Generalized Epilepsy
    Welch, William P.
    Sitwat, Bilal
    Sogawa, Yoshimi
    JOURNAL OF CHILD NEUROLOGY, 2018, 33 (07) : 449 - 452