Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners

被引:11
|
作者
Saba, Luca [1 ]
di Martino, Michele [3 ]
Siotto, Paolo [2 ]
Anzidei, Michele [3 ]
Argiolas, Giovanni Maria [2 ]
Porcu, Michele [2 ]
Suri, Jasjit S. [4 ]
Wintermark, Max [5 ]
机构
[1] AOU, Dept Radiol, Cagliari Polo Monserrato Ss 554, I-09045 Cagliari, Italy
[2] Azienda Osped Brotzu, Dept Radiol, I-09100 Cagliari, Italy
[3] Univ Roma La Sapienza, Dept Radiol, Rome, Italy
[4] AtheroPoint TM, Monitoring & Diagnost Div, Roseville, CA USA
[5] Stanford Sch Med, Dept Neuroradiol, 291 Campus Dr, Stanford, CA 94305 USA
关键词
CTA; Radiation dose; CAROTID PLAQUE; ENERGY CT; ANGIOGRAPHY; STENOSIS; RISK; VOLUME; SIZE;
D O I
10.1016/j.neurad.2017.09.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. - The purpose of this work was to compare the image quality and radiation dose delivered to patients during computed tomography (CT) angiography (CTA) of the supra-aortic arteries using two single-source (SS) and two dual-energy (DE) CT scanners. Material and methods. - In this retrospective study, 120 patients who underwent CTA of supra-aortic arteries were studied using four different types of CT scanners: a sixteen and forty-detector-row SS and two DE CT scanners. Seventy milliters of contrast medium were injected at a flow rate of 4 mL/s using a power injector. For each patient the dose-length product (DLP), the volume computed tomography dose index (CDTlvol), the length of the scan and the effective dose (ED) were calculated. Qualitative and quantitative [image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] image quality assessment was performed. Results. - A statistically significant lower value of the DE compared to the SS technology (P<0.0001) for the CDTI, DLP and ED was found, whereas we did not find any statistically significant difference between the four scanners for the measurements of the image noise, SNR and CNR. Conclusion. - DS CT scanners allow performing CTAs with a reduced dose compared to SS CT scanner with comparable image quality. (C) 2017 Published by Elsevier Masson SAS.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [41] Radiation Dose and Image Quality in Pediatric Cardiac Computed Tomography: A Comparison Between Sequential and Third-Generation Dual-Source High-Pitch Spiral Techniques
    Koh, Huiliang
    Ong, Ching Ching
    Choo, Yun Song
    Liang, Chong Ri
    Tan, Grace Hui Zhen
    Lim, Terence Chee Wen
    Quek, Swee Chye
    Sriram, Shankar
    San Teo, Lynette Li
    PEDIATRIC CARDIOLOGY, 2016, 37 (08) : 1397 - 1403
  • [42] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [43] Truncus arteriosus: Diagnosis with dual-source computed tomography angiography and low radiation dose
    Koplay, Mustafa
    Cimen, Derya
    Sivri, Mesut
    Guvenc, Osman
    Arslan, Derya
    Nayman, Alaaddin
    Oran, Bulent
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (11): : 886 - 889
  • [44] The effect of heart rhythm on patient radiation dose with dual-source cardiac computed tomography
    Techasith, Tust
    Ghoshhajra, Brian B.
    Truong, Quynh A.
    Pale, Rodrigo
    Nasir, Khurram
    Bolen, Michael A.
    Hoffmann, Udo
    Cury, Ricardo C.
    Abbara, Suhny
    Brady, Thomas J.
    Blankstein, Ron
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 255 - 263
  • [45] Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods
    Ueguchi, Takashi
    Ogihara, Ryota
    Yamada, Sachiko
    ACADEMIC RADIOLOGY, 2018, 25 (12) : 1632 - 1639
  • [46] Comparison of Diagnostic Accuracy and Radiation Dose Between Prospective Triggering and Retrospective Gated Coronary Angiography by Dual-Source Computed Tomography
    Lu, Bin
    Lu, Jin-Guo
    Sun, Ming-Li
    Hou, Zhi-Hui
    Chen, Xiong-Biao
    Tang, Xiang
    Wu, Run-Ze
    Johnson, Laura
    Qiao, Shu-Bin
    Yang, Yue-Jin
    Jiang, Shi-Liang
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (09): : 1278 - 1284
  • [47] Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT
    Rixe, J.
    Conradi, G.
    Rolf, A.
    Schmermund, A.
    Magedanz, A.
    Erkapic, D.
    Deetjen, A.
    Hamm, C. W.
    Dill, T.
    HEART, 2009, 95 (16) : 1337 - 1342
  • [48] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Thomas Schertler
    Hans Scheffel
    Thomas Frauenfelder
    Lotus Desbiolles
    Sebastian Leschka
    Paul Stolzmann
    Burkhardt Seifert
    Thomas G. Flohr
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2007, 17 : 3179 - 3188
  • [49] Diagnostic Accuracy and Image Quality of Cardiac Dual-Source Computed Tomography in Patients with Arrhythmia
    Drosch, Tanja
    Reimann, Anja
    Brodoefel, Harald
    Tsiflikas, Ilias
    Thomas, Christoph
    Heuschmid, Martin
    Schroeder, Stephen
    Burgstahler, Christof
    CIRCULATION, 2008, 118 (18) : S845 - S845
  • [50] Image Quality and Dose Reduction by Dual Source Computed Tomography Coronary Angiography: Protocol Comparison
    Forte, Ernesto
    Monti, Serena
    Parente, Chiara Anna
    Beyer, Lukas
    De Rosa, Roberto
    Infante, Teresa
    Cavaliere, Carlo
    Cademartiri, Filippo
    Salvatore, Marco
    Stroszczynski, Christian
    Tedeschi, Carlo
    DOSE-RESPONSE, 2018, 16 (04):