The electromagnetic barrel calorimeter for the GlueX experiment

被引:0
|
作者
Barbi, M. [1 ]
机构
[1] Univ Regina, Dept Phys, Regina, SK S4S 0A2, Canada
来源
Calorimetry in High Energy Physics | 2006年 / 867卷
关键词
GlueX; hybrid mesons; calorimeter; silicon-photomultipliers; scintillator fiber;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number of approximately 3000 readout channels with silicon-photomultiplier-based photo-sensors for light collection. The calorimeter is expected to achieve energy and time resolution better than [GRAPHICS] and 200 ps, respectively. In this contribution we present an overview of the calorimeter design and some preliminary studies of its performance using Monte Carlo simulations and beam test measurements.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [31] Performance of Prototypes for the Barrel Part of the PANDA Electromagnetic Calorimeter
    Rosenbaum, Christoph
    Diehl, S.
    Dormenev, V
    Drexler, P.
    Kavatsyuk, M.
    Kuske, T.
    Nazarenko, S.
    Novotny, R.
    Rosier, P.
    Ryazantsev, A.
    Wieczorek, P.
    Wilms, A.
    Zaunick, H-G
    FAIRNESS 2016, 2016, 742
  • [32] Performance of the ATLAS electromagnetic calorimeter barrel module 0
    Aubert, B
    Ballansat, J
    Bazan, A
    Beaugiraud, B
    Boniface, J
    Chollet, F
    Colas, J
    Delebecque, P
    Di Ciaccio, L
    Dumont-Dayot, N
    El Kacimi, M
    Gaumer, O
    Ghez, P
    Girard, C
    Gouanère, M
    Kambara, H
    Jérémie, A
    Jézéquel, S
    Lafaye, R
    Leflour, T
    Le Maner, C
    Lesueur, J
    Massol, N
    Moynot, M
    Neukermans, L
    Perrodo, P
    Perrot, G
    Poggioli, L
    Prast, J
    Przysiezniak, H
    Riccadona, X
    Sauvage, G
    Thion, J
    Wingerter-Seez, I
    Zitoun, R
    Zolnierowski, Y
    Chen, H
    Citterio, M
    Farrell, J
    Gordon, H
    Hackenburg, B
    Hoffman, A
    Kierstead, J
    Lanni, F
    Leite, M
    Lissauer, D
    Ma, H
    Makowiecki, D
    Radeka, V
    Rahm, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 500 (1-3): : 202 - 231
  • [33] ATLAS electromagnetic barrel calorimeter performance in recent testbeams
    Lafaye, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 82 - 84
  • [34] The design of the cooling system for the CMS barrel electromagnetic calorimeter
    Teller, Olivier
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1748 - 1752
  • [35] Performance of the electromagnetic calorimeter of the HERMES experiment
    Avakian, H
    Bianchi, N
    Capitani, GP
    De Sanctis, E
    Di Nezza, P
    Fantoni, A
    Giourdjian, V
    Mozzetti, R
    Muccifora, V
    Nupieri, M
    Reolon, AR
    Rossi, P
    van den Brand, JFJ
    Doets, M
    Henkes, T
    Kolstein, M
    Airapetian, A
    Akopov, N
    Amarian, M
    Avakian, R
    Avetissian, A
    Garibian, V
    Taroian, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 417 (01): : 69 - 78
  • [36] Calibration of the electromagnetic calorimeter of the CMS experiment
    Tabarelli de Fatis, T.
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [37] Experiment 705 electromagnetic shower calorimeter
    Antoniazzi, L.
    Arenton, M.
    Cao, Z.
    Conetti, S.
    Cox, B.
    Delchamps, S.
    Fortney, L.
    Guffey, K.
    Haire, M.
    He, M.
    Ioannou, P.
    Jenkins, C.M.
    Judd, D.J.
    Kourkoumelis, C.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A332 (1-2): : 57 - 77
  • [38] THE EXPERIMENT 705 ELECTROMAGNETIC SHOWER CALORIMETER
    ANTONIAZZI, L
    ARENTON, M
    CAO, Z
    CHEN, TY
    CONETTI, S
    COX, B
    DELCHAMPS, S
    FORTNEY, L
    GUFFEY, K
    HAIRE, M
    HE, M
    IOANNOU, P
    JENKINS, CM
    JUDD, DJ
    KOURKOUMELIS, C
    MANOUSAKISKATSIKAKIS, A
    KUZMINSKI, J
    LECOMPTE, T
    MARCHIONNI, A
    MAZUR, PO
    MURPHY, CT
    PRAMANTIOTIS, P
    RAMEIKA, R
    RESVANIS, L
    ROSATI, M
    ROSEN, J
    SHEN, CH
    SHEN, Q
    SIMARD, A
    SMITH, R
    SPIEGEL, L
    STAIRS, D
    TAN, Y
    TESAREK, RJ
    TURKINGTON, T
    TURNBULL, L
    TURKOT, F
    TZAMARIAS, S
    VOULGARIS, G
    WAGONER, DE
    WANG, C
    WECKEL, J
    YANG, W
    YAO, N
    ZHANG, N
    ZHANG, X
    ZIOULAS, G
    ZOU, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2): : 57 - 77
  • [39] The Electromagnetic Calorimeter of the CMS Experiment.
    Longo, Egidio
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 182 - 184
  • [40] Calibration of the Electromagnetic Calorimeter of the CMS experiment
    Argiro, S.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2009, 197 : 362 - 365