Two Propagation Scenarios of Isolated Breakdown Lightning Processes in Failed Negative Cloud-to-Ground Flashes

被引:5
|
作者
Kolmasova, Ivana [1 ,2 ]
Santolik, Ondrej [1 ,2 ]
Defer, Eric [3 ]
Kaspar, Petr [1 ]
Kolinska, Andrea [1 ,4 ]
Pedeboy, Stephane [5 ]
Coquillat, Sylvain [3 ]
机构
[1] Czech Acad Sci, Inst Atmospher Phys, Dept Space Phys, Prague, Czech Republic
[2] Charles Univ Prague, Fac Math & Phys, Prague, Czech Republic
[3] Univ Toulouse, CNRS, OMP, Lab Aerol,UPS, Toulouse, France
[4] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Prague, Czech Republic
[5] Meteorage, Pau, France
关键词
isolated breakdown process; negative cloud-to-ground flash; strong lower positive charge region; inverted IC dicharges; INITIAL BREAKDOWN; CHARGE STRUCTURE; PEAK CURRENTS; MODEL; PULSE; DISCHARGES; SYSTEM; INTRACLOUD;
D O I
10.1029/2020GL090593
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Isolated breakdown process (also known as attempted leader or inverted intra-cloud discharge) is a lightning phenomenon characterized by radio wave pulses similar to signatures of preliminary breakdown before negative cloud-to-ground flashes, but in this case no cloud-to-ground return strokes occur. We identified 128 isolated breakdown pulse trains in measurements collected in the Mediterranean by a broadband receiver (0.005-7 MHz) in 2015 and 2018. By combining these records with concurrent Lightning Mapping Array measurements of very high frequency radiation (60-66 MHz) emitted by in-cloud discharges we investigate the development of each discharge. We identify two scenarios: Either the discharges continue to propagate almost horizontally for more than 150 ms (73%), or they quickly fade out (27%). The geo-localized sources of the observed isolated breakdown pulse trains, together with their waveform characteristics (duration, inter-pulse intervals, regularity, and bipolar shapes) show that both scenarios are similar to initiation processes preceding negative cloud-to-ground flashes. Plain Language Summary Visible lightning return stroke represents a well-known manifestation of atmospheric electricity. However, it is only the last stage of a complex sequence of phenomena that starts inside an electrically charged thundercloud by a preliminary breakdown process, continues by a stepped leader that moves electrical charges into the lightning channel, neutralized eventually by a large return stroke current and followed in most cases by processes leading to subsequent strokes. All these phenomena occurring inside or below the thundercloud involve impulsive electrical currents and hence emit radio waves. Analysis of our observations of isolated breakdown radio wave pulses which are not followed by a return stroke shows that the underlying processes are similar to a usual preliminary breakdown preceding negative cloud-to ground discharges. Nevertheless, a strong positive charge layer at the bottom of the thundercloud can force the breakdown current pulses to keep flowing inside the cloud or die out and thus prevents them from evolving into a return stroke that would move the negative charge from the cloud to the ground. Key Points Preliminary breakdown radio wave pulses typical for negative cloud-to-ground flashes are exceptionally observed without return strokes Data show evidence of two possible propagation scenarios: The discharge leader either extends horizontally inside the cloud or fades out The first analysis of a large number of events shows that waveform characteristics of pulse trains are very similar for both scenarios
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Monthly distribution of cloud-to-ground lightning flashes as observed by lightning location systems
    Pinto, O., Jr.
    Naccarato, K. P.
    Pinto, I. R. C. A.
    Fernandes, W. A.
    Neto, O. Pinto
    GEOPHYSICAL RESEARCH LETTERS, 2006, 33 (09)
  • [32] Characterization of negative cloud-to-ground lightning in Florida
    Zhu, Yanan
    Rakov, Vladimir A.
    Mallick, Shreeharsh
    Tran, Manh D.
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2015, 136 : 8 - 15
  • [33] CONTINUING CURRENT IN NEGATIVE CLOUD-TO-GROUND LIGHTNING
    SHINDO, T
    UMAN, MA
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1989, 94 (D4): : 5189 - 5198
  • [34] Halos generated by negative cloud-to-ground lightning
    Frey, H. U.
    Mende, S. B.
    Cummer, S. A.
    Li, J.
    Adachi, T.
    Fukunishi, H.
    Takahashi, Y.
    Chen, A. B.
    Hsu, R.-R.
    Su, H.-T.
    Chang, Y.-S.
    GEOPHYSICAL RESEARCH LETTERS, 2007, 34 (18)
  • [35] LONG CONTINUING CURRENTS IN NEGATIVE CLOUD-TO-GROUND LIGHTNING FLASHES - OCCURRENCE STATISTICS AND HYPOTHETICAL MECHANISM
    RAKOV, VA
    UMAN, MA
    IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1991, 27 (04): : 376 - 390
  • [36] Evaluation of the Existence of Initial Breakdown Process for Cloud-to-Ground Flashes
    Zikri, Muhammad
    Sidik, Muhammad Abu Bakar
    Ahmad, Mohd Riduan
    Sabri, Muhammad Haziq Mohammad
    Periannan, Dinesh
    Esa, Mona Riza Mohd
    Abdul-Malek, Zulkarnain
    Lu, Gaopeng
    Zhang, Hongbo
    2018 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND COMPUTER SCIENCE (ICECOS), 2018, : 425 - 428
  • [37] Winter Positive Cloud-to-Ground Lightning Flashes Observed by LMA in Japan
    Wang, Daohong
    Zheng, Dong
    Wu, Ting
    Takagi, Nobuyuki
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2021, 16 (03) : 402 - 411
  • [38] Electric fields changes produced by positives cloud-to-ground lightning flashes
    Schumann, Carina
    Fares Saba, Marcelo Magalhaes
    Guedes da Silva, Raphael Bueno
    Schulz, Wolfgang
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2013, 92 : 37 - 42
  • [39] Analyses of negative cloud-to-ground flashes and their ground strike points in Austria
    Schwalt, Lukas
    Schulz, Wolfgang
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 217
  • [40] Characterization of Negative Cloud-to-Ground Lightning in Florida: Revisited
    Zhu, Y.
    Rakov, V. A.
    Mallick, S.
    Tran, M. D.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1830 - 1834