Use of spiral computed tomography for multiplanar dental reconstruction

被引:30
|
作者
Preda, L
DiMaggio, EM
Dore, R
LaFianza, A
Solcia, M
Schifino, MR
Campani, R
Preda, EG
机构
[1] Istituto di Radiologia, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[2] Clinica Odontoiatrica, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[3] Istituto di Radiologia, IRCCS Policlinico S Matteo, 27100 Pavia, p.le Golgi
关键词
tomography; X-ray computed; dental implantation; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare spiral with conventional CT for multiplanar reconstruction (MPR) prior to dental implant placement. Methods: Ten patients underwent conventional and then Spiral CT at 1 mm slice thickness. In six patients (Group A) the pitch was 1:1, the other four (Group B) it was 2:1. Image quality and clinical features were evaluated separately on axial and reconstructed images by two experienced radiologists who scored each parameter from 1 (poor, non-diagnostic) to 3 (good, diagnostic). Results: Loss of spatial resolution with spiral CT was not significant and the diagnostic yield poorer only for trabecular bone structure. The MPRs were better and depiction of the mandibular canal more reliable. Conclusions: We recommend the use of spiral CT instead of conventional CT for dental MPR because examination time is shorter and patient comfort is improved. Use of a pitch of 2:1 permits a marked reduction in X-ray dose with no loss of image quality.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [21] EFFECT OF IMAGE DISPLAY ON THE QUALITY OF MULTIPLANAR RECONSTRUCTION OF COMPUTED-TOMOGRAPHY DATA
    FISHMAN, EK
    NEY, DR
    KAWASHIMA, A
    SCOTT, WW
    ROBERTSON, DD
    INVESTIGATIVE RADIOLOGY, 1993, 28 (02) : 146 - 149
  • [22] COMPUTED-TOMOGRAPHY MULTIPLANAR REFORMATION
    不详
    WESTERN JOURNAL OF MEDICINE, 1985, 142 (06): : 786 - 786
  • [23] Assessing torsion of the medial cortex of the canine tibia using computed tomography multiplanar reconstruction
    Hette, K.
    Anderson, A. A.
    Barnes, D. M.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2016, 57 (05) : 234 - 239
  • [24] High-resolution computed tomography using multiplanar reconstruction for the facial nerve canal
    Watanabe, Y
    Sugai, Y
    Hosoya, T
    Yamaguchi, K
    Aoyagi, M
    ACTA OTO-LARYNGOLOGICA, 2000, : 44 - 48
  • [25] Measurement of angle and length of the eustachian tube on computed tomography using the multiplanar reconstruction technique
    Takasaki, Kenji
    Takahashi, Haruo
    Miyamoto, Ikue
    Yoshida, Haruo
    Yamamoto-Fukuda, Tomomi
    Enatsu, Kaori
    Kumagami, Hidetaka
    LARYNGOSCOPE, 2007, 117 (07): : 1251 - 1254
  • [26] Detection of a giant wooden foreign body with multidetector computed tomography and multiplanar reconstruction imaging
    Kantarci, Mecit
    Ogul, Hayri
    Karasen, R. Murat
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2007, 25 (02): : 211 - 213
  • [27] Use of multislice spiral computed tomography in neuroradiological imaging
    Klingebiel, R
    Bohner, G
    Zimmer, C
    Rogalla, P
    Masuhr, F
    Lehmann, R
    NERVENARZT, 2002, 73 (08): : 729 - +
  • [28] Multiplanar reformation computed tomography for carpal malalignment
    Schormans, Philip M. J.
    Schots, Judith P. M.
    Weijers, Rene E.
    Loeffen, Daan V.
    Poeze, Martijn
    Hannemann, Pascal F. W.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (10) : 1049 - 1055
  • [29] MULTIPLANAR COMPUTED-TOMOGRAPHY OF ACETABULAR FRACTURES
    MAGID, D
    FISHMAN, EK
    BROOKER, AF
    MANDELBAUM, BR
    SIEGELMAN, SS
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 778 - 783
  • [30] GATED MULTIPLANAR CARDIAC COMPUTED-TOMOGRAPHY
    JOHNSON, GA
    GODWIN, JD
    FRAM, EK
    RADIOLOGY, 1982, 145 (01) : 195 - 197