Use of spiral computed tomography for multiplanar dental reconstruction

被引:30
|
作者
Preda, L
DiMaggio, EM
Dore, R
LaFianza, A
Solcia, M
Schifino, MR
Campani, R
Preda, EG
机构
[1] Istituto di Radiologia, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[2] Clinica Odontoiatrica, IRCCS Policlinico S Matteo, Università di Pavia, Pavia
[3] Istituto di Radiologia, IRCCS Policlinico S Matteo, 27100 Pavia, p.le Golgi
关键词
tomography; X-ray computed; dental implantation; image processing; computer-assisted;
D O I
10.1038/sj.dmfr.4600290
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare spiral with conventional CT for multiplanar reconstruction (MPR) prior to dental implant placement. Methods: Ten patients underwent conventional and then Spiral CT at 1 mm slice thickness. In six patients (Group A) the pitch was 1:1, the other four (Group B) it was 2:1. Image quality and clinical features were evaluated separately on axial and reconstructed images by two experienced radiologists who scored each parameter from 1 (poor, non-diagnostic) to 3 (good, diagnostic). Results: Loss of spatial resolution with spiral CT was not significant and the diagnostic yield poorer only for trabecular bone structure. The MPRs were better and depiction of the mandibular canal more reliable. Conclusions: We recommend the use of spiral CT instead of conventional CT for dental MPR because examination time is shorter and patient comfort is improved. Use of a pitch of 2:1 permits a marked reduction in X-ray dose with no loss of image quality.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [1] Evaluation of intraocular foreign bodies by spiral computed tomography and multiplanar reconstruction
    Lakits, A
    Steiner, E
    Scholda, C
    Kontrus, M
    OPHTHALMOLOGY, 1998, 105 (02) : 307 - 312
  • [2] MULTIPLANAR RECONSTRUCTION IN COMPUTED-TOMOGRAPHY OF THE ORBIT
    ZILKHA, A
    COMPUTERIZED RADIOLOGY, 1982, 6 (01): : 57 - 62
  • [3] COMPUTED-TOMOGRAPHY WITH MULTIPLANAR RECONSTRUCTION OF ACETABULAR FRACTURES
    SCHOLTEN, ET
    VANDERLANDE, BAE
    WILLEMSE, APP
    ELZENGA, P
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1986, 55 (4-5) : 203 - 209
  • [4] Assessment of femoral neck nonunion with multiplanar computed tomography reconstruction
    Savolaine, ER
    Ebraheim, N
    ORTHOPEDICS, 2000, 23 (07) : 713 - 715
  • [5] Validation of spiral computed tomography for dental implants
    Cavalcanti, MGP
    Yang, J
    Ruprecht, A
    Vannier, MV
    DENTOMAXILLOFACIAL RADIOLOGY, 1998, 27 (06) : 329 - 333
  • [6] Multiplanar Computed Tomography Reconstruction to Diagnose Lemierre's Syndrome
    Shires, Courtney Brooke
    Klug, Theodore
    Shete, Mona
    Sebelik, Merry
    OTO OPEN, 2020, 4 (03)
  • [7] PHYSICAL CONSIDERATIONS OF MULTIPLANAR RECONSTRUCTION TECHNIQUES IN COMPUTED-TOMOGRAPHY
    SHAW, CG
    BASSANO, DA
    LU, YQ
    MEDICAL PHYSICS, 1983, 10 (04) : 525 - 525
  • [8] Three-dimensional reconstruction of human diaphragm with the use of spiral computed tomography
    Pettiaux, N
    Cassart, M
    Paiva, M
    Estenne, M
    JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (03) : 998 - 1002
  • [9] Development of an automatic multiplanar reconstruction processing method for head computed tomography
    Sato, Mitsuru
    Kondo, Yohan
    Takahashi, Noriyuki
    Ohmura, Tomomi
    Takahashi, Naoya
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 777 - 788
  • [10] COMPARISON OF SPIRAL COMPUTED-TOMOGRAPHY VERSUS CONVENTIONAL COMPUTED-TOMOGRAPHY MULTIPLANAR RECONSTRUCTIONS OF A FRACTURE DISPLACEMENT PHANTOM
    MCENERY, KW
    WILSON, AJ
    MURPHY, WA
    INVESTIGATIVE RADIOLOGY, 1994, 29 (07) : 665 - 670