摘要
Newly developed expendable immersion optical fiber thermometer is a possible choice for the temperature measurement of the melts in copper pyrometallurgy. With this method the radiation is collected directly from inside the melt and transmitted to the pyrometer through the fiber, so that the measurement accuracy is hardly influenced by the surface condition and emissivity change of the melts, diffused reflection on the melt surface, and atmosphere, i.e. burner flame, combustion gases, dust etc. Since the fiber is expendable, this method is free from accretion problem as well. A series of plant tests were carried out in order to develop its application to the molten blister copper at the outlet of the continuous converter. The immersion time required for each measurement was less than 5 seconds, and the degree of accuracy was within +/-2 similar to 5K. Consumption of the fiber was less than 0.01m for each measurement on average. Based on the obtained results, an automated temperature measurement system for molten blister copper was designed and installed at Naoshima Smelter & Refinery of Mitsubishi Materials Corporation.
引用
收藏
页码:912 / 915
页数:4
相关论文
共 50 条
  • [21] Analysis of turbulent flow in silicon melts by optical temperature measurement
    Gräbner, O
    Mühe, A
    Müller, G
    Tomzig, E
    Virbulis, J
    von Ammon, W
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 2000, 73 (1-3): : 130 - 133
  • [22] Shipborne expendable all-optical fiber ocean temperature-depth profile sensor
    Zhao, Qiang
    Wang, Yinglong
    Sun, Peng
    Du, Dawei
    Yu, Luyao
    Zhang, Jianwei
    Ding, Baoyan
    Han, Guihai
    Qu, Yi
    APPLIED OPTICS, 2022, 61 (08) : 2089 - 2095
  • [23] Direct measurement of fiber temperature in the continuous drawing process of PET fiber heated by CO2 laser radiation
    Okumura, W
    Yamaguchi, T
    Ohkoshi, Y
    Gotoh, Y
    Nagura, M
    INTERNATIONAL POLYMER PROCESSING, 2002, 17 (02) : 124 - 132
  • [24] CONTINUOUS TEMPERATURE MEASUREMENT IN MOLTEN METALS ESPECIALLY IN LD CONVERTER
    STROHMEI.G
    SEDLATSC.K
    PIPITZ, E
    CHEMIE INGENIEUR TECHNIK, 1968, 40 (06) : 307 - &
  • [25] CONTINUOUS MEASUREMENT OF LOCAL CONCENTRATION BY AN OPTICAL FIBER PROBE
    HATANO, H
    ISHIDA, M
    KAGAKU KOGAKU RONBUNSHU, 1982, 8 (03) : 219 - 224
  • [26] MEASUREMENT OF PEAK TEMPERATURE ALONG AN OPTICAL FIBER
    FOX, RJ
    APPLIED OPTICS, 1983, 22 (07): : 967 - 969
  • [27] Direct measurement of design margins with an optical fiber emulator
    Barbeau, NR
    PHOTONICS NORTH: APPLICATIONS OF PHOTONIC TECHNOLOGY, PTS 1 AND 2: CLOSING THE GAP BETWEEN THEORY, DEVELOPMENT, AND APPLICATION, 2004, 5579 : 499 - 507
  • [28] The accuracy and precision of tympanic temperature with a new optical fiber thermometer during cardiac surgery
    Matsukawa, T
    Kawamura, A
    Ozaki, M
    Kumazawa, T
    ANESTHESIOLOGY, 2000, 93 (3A) : U146 - U146
  • [29] Optical Noninvasive Temperature Measurement of Molten Melts in Metallurgical Process: A Review
    Xinyu Wu
    Jiahao Li
    Feifei Liu
    Chunfa Liao
    Shumei Chen
    Xiaojun Wang
    MAPAN, 2022, 37 : 793 - 809
  • [30] Optical Noninvasive Temperature Measurement of Molten Melts in Metallurgical Process: A Review
    Wu, X.
    Li, J.
    Liu, F.
    Liao, C.
    Chen, S.
    Wang, X.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (04): : 793 - 809