Laser alignment system for helical pinhole SPECT

被引:9
|
作者
Metzler, SD [1 ]
Greer, KL
Bobkov, K
Jaszczak, RJ
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Dept Biomed Engn, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
alignment; calibration; pinhole; single photon emission computed tomography (SPECT); small animal;
D O I
10.1109/TNS.2004.829749
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pinhole single photon emission computed tomography (SPECT) is very sensitive to mechanical alignment because it is a magnifying geometry. Because of magnification, small mechanical shifts of the aperture result in a large change in the projection data. Helical orbits may be used for pinhole SPECT to improve the completeness of the projection data. This has been done by using a research scanner to provide rotation while a linear stage produces axial movement. The combined effect is a helical orbit. However, reconstruction quality may be limited by the alignment of the linear stage with the axis of rotation of the scanner. We have developed a laser system for aligning the linear stage. We present the system design and estimate the accuracy of its alignment. Experimental helical pinhole SPECT data are presented.
引用
收藏
页码:603 / 610
页数:8
相关论文
共 50 条
  • [21] Simulation Study of a Pinhole SPECT System with a Triple Head Gamma Camera
    Ichimura, Yuta
    Ogawa, Koichi
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [22] Multi-Pinhole SPECT System with a Triple Head Gamma Camera
    Kubota, Hayao
    Hemuki, Yutaro
    Motomura, Nobutoku
    Ogawa, Koichi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [23] Performance evaluation of a pinhole SPECT system for myocardial perfusion imaging of mice
    Wu, MC
    Hasegawa, BH
    Dae, MW
    MEDICAL PHYSICS, 2002, 29 (12) : 2830 - 2839
  • [24] Determination of the analytical point spread function of a pinhole aperture SPECT system
    Bekaert, V
    Brasse, D
    Gizard, B
    Guyonnet, JL
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2565 - 2569
  • [25] Optimizing a multiple-pinhole SPECT system using the ideal observer
    Gross, K
    Kupinski, MA
    Peterson, T
    Clarkson, E
    MEDICAL IMAGING 2003: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2003, 5034 : 314 - 322
  • [26] Multi-pinhole Dynamic SPECT Imaging: Simulation and System Optimization
    Ma, Dan
    Clough, Anne V.
    Schmidt, Taly Gilat
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [27] Triple Head Multi Pinhole Brain SPECT System for striatal imaging
    Forgacs, A.
    Wirth, A.
    Bukki, T.
    Pechan, J.
    Barna, S.
    Nagy, L.
    Hopin, J.
    Garai, I.
    Verma, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S513 - S513
  • [28] Design of compact pinhole SPECT system based on flat panel PMT
    Pellegrini, R
    Pani, R
    Cusanno, F
    Garibaldi, F
    Ridolfi, S
    Mattioli, M
    Majewski, S
    Tsui, BMW
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1828 - 1832
  • [29] Simulation Study on a Stationary SPECT System With Multi-pinhole Collimators
    Kubota, Hayao
    Motomura, Nobutoku
    Ogawa, Koichi
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [30] Comparison of a Multi-pinhole Stationary SPECT System and a Parallel-hole High Speed Rotational SPECT system
    Fujishiro, Yohei
    Murata, Kazumi
    Motomura, Nobutoku
    Ogawa, Koichi
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,