Molecularly imprinted hornlike polymer@electrochemically reduced graphene oxide electrode for the highly selective determination of an antiemetic drug

被引:25
|
作者
Kumar, Deivasigamani Ranjith [1 ]
Dhakal, Ganesh [1 ]
Van Quang Nguyen [1 ,2 ]
Shim, Jae-Jin [1 ]
机构
[1] Yeungnam Univ, Sch Chem Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
[2] Univ Sci & Technol, Univ Da Nang, Dept Rd & Bridge Engn, 54 Nguyen Luong Bang, Da Nang, Vietnam
基金
新加坡国家研究基金会;
关键词
Polypyrrole; Molecularly imprinted polymer; Imprinting factor; Domperidone; Differential pulse voltammetry; FUNCTIONALIZED GRAPHENE; POLYPYRROLE; SENSOR; DOMPERIDONE; REDUCTION; NANOTUBES; COMPOSITE; WATER;
D O I
10.1016/j.aca.2020.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Robust, highly selective, and sensitive sensor devices are in high demand for the detection of bioactive molecules. Bioactive molecules are quantified by the electrochemical approach in the presence of other interference species, presenting a significant challenge to researchers. In this study, molecularly imprinted polymer (MIP) was prepared using the electrochemical method in a methanol/water solution mixture. The MIP on the electrochemically reduced graphene oxide (ERGO) surface exhibited hornlike morphology in contrast to the bare GC obtained, forming irregular bulky structures with a size range of 0.8-2.1 mu m. The domperidone (DP) binding/extraction from MIP@ERGO was studied using ex situ Fourier transform infrared and X-ray photoelectron spectroscopy. The hornlike MIP@ERGO/GC revealed a higher heterogeneous electron transfer rate constant and DP antiemetic drug oxidation current response compared with the MIP/GC and non-imprinted polymer (NIP/GC) electrodes. The hornlike MIP@ERGO/GC electrode fabrication was optimized in terms of the pyrrole polymerization cyclic voltammetry cycle number, monomer/template concentration, and incubation times. The fabricated MIP@ERGO/GC electrode demonstrated a wide concentration range of DP detection (from 0.5 to 17.2 mu M), and the limit of detection was found to be 3.8 nM, with a signal-to-noise ratio of 3. Moreover, the MIP@ERGO/GC electrode had excellent DP selectivity (with an imprinting factor of 4.20), even in the presence of ascorbic acid, uric acid, dopamine, xanthine, gelatin, glucose, sucrose, t-cysteine, folic acid, K+, Na+, Ca2+, CO32-, SO42-, and NO32- interferences. The MIP@ERGO/GC electrode was tested on a human urine sample, and DP recovery ranges between 98.4% and 100.87% were obtained. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [41] Electrochemical sensor based on a carbon paste electrode modified by graphene nanosheets and molecularly imprinted polymer nanoparticles for determination of a chlordiazepoxide drug
    Motaharian, Ali
    Hosseini, Mohammad Reza Milani
    ANALYTICAL METHODS, 2016, 8 (33) : 6305 - 6312
  • [42] A Selective Joint Determination of Salicylic Acid in Actinidia chinensis Combining a Molecularly Imprinted Monolithic Column and a Graphene Oxide Modified Electrode
    Zhou, Can
    Chen, Jianxiong
    Dang, Xueping
    Ma, Xiwen
    Ai, Youhong
    Huang, Jianlin
    Chen, Huaixia
    ANALYTICAL SCIENCES, 2018, 34 (07) : 823 - 829
  • [43] Selective determination of chloramphenicol at trace level in milk samples by the electrode modified with molecularly imprinted polymer
    Alizadeh, Taher
    Ganjali, Mohamad Reza
    Zare, Mashaalah
    Norouzi, Parviz
    FOOD CHEMISTRY, 2012, 130 (04) : 1108 - 1114
  • [44] A Selective Joint Determination of Salicylic Acid in Actinidia chinensis Combining a Molecularly Imprinted Monolithic Column and a Graphene Oxide Modified Electrode
    Can Zhou
    Jianxiong Chen
    Xueping Dang
    Xiwen Ma
    Youhong Ai
    Jianlin Huang
    Huaixia Chen
    Analytical Sciences, 2018, 34 : 823 - 829
  • [45] Electrochemical behavior of eriocitrin and highly sensitive determination based on an electrochemically reduced graphene oxide modified glassy carbon electrode
    Yao, Shuyu
    Cai, Wanling
    Liu, Lin
    Liao, Xueqing
    Tao, Kaili
    Feng, Fang
    Yang, Gongjun
    ANALYTICAL METHODS, 2016, 8 (18) : 3722 - 3729
  • [46] Electrochemically Reduced Graphene Oxide as Screen-printed Electrode Modifier for Fenamiphos Determination
    Gevaerd, A.
    Watanabe, E. Y.
    Fernandes, K.
    Papi, M. A. P.
    Banks, C. E.
    Bergamini, M. F.
    Marcolino-Junior, L. H.
    ELECTROANALYSIS, 2020, 32 (08) : 1689 - 1695
  • [47] Amperometric determination of promethazine in tablets using an electrochemically reduced graphene oxide modified electrode
    Felix, Fabiana S.
    Ferreira, Luis M. C.
    Vieira, Fernanda
    Trindade, Gerald M.
    Ferreira, Viviane S. S. A.
    Angnes, Lucio
    NEW JOURNAL OF CHEMISTRY, 2015, 39 (01) : 696 - 702
  • [48] Total Determination of Estrogenic Phenolic Compounds in River Water Using a Sensor Based on Reduced Graphene Oxide and Molecularly Imprinted Polymer
    Braga, Guilherme Bettio
    Ferreira Oliveira, Ana Elisa
    Pereira, Arnaldo Cesar
    ELECTROANALYSIS, 2018, 30 (09) : 2176 - 2184
  • [49] A highly selective electrochemical sensor for 4-chlorophenol determination based on molecularly imprinted polymer and PDDA-functionalized graphene
    Wang, Bin
    Okoth, Otieno Kevin
    Yan, Kai
    Zhang, Jingdong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 294 - 303
  • [50] Synthesis and characterization of magnetic molecularly imprinted polymer of polydopamine/graphene oxide as drug carrier for rivastigmine
    Khaneghah, Sahel Sani
    Sohrabi, Negin
    Mohammadi, Reza
    JOURNAL OF MOLECULAR LIQUIDS, 2023, 391