Molecularly imprinted hornlike polymer@electrochemically reduced graphene oxide electrode for the highly selective determination of an antiemetic drug

被引:25
|
作者
Kumar, Deivasigamani Ranjith [1 ]
Dhakal, Ganesh [1 ]
Van Quang Nguyen [1 ,2 ]
Shim, Jae-Jin [1 ]
机构
[1] Yeungnam Univ, Sch Chem Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
[2] Univ Sci & Technol, Univ Da Nang, Dept Rd & Bridge Engn, 54 Nguyen Luong Bang, Da Nang, Vietnam
基金
新加坡国家研究基金会;
关键词
Polypyrrole; Molecularly imprinted polymer; Imprinting factor; Domperidone; Differential pulse voltammetry; FUNCTIONALIZED GRAPHENE; POLYPYRROLE; SENSOR; DOMPERIDONE; REDUCTION; NANOTUBES; COMPOSITE; WATER;
D O I
10.1016/j.aca.2020.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Robust, highly selective, and sensitive sensor devices are in high demand for the detection of bioactive molecules. Bioactive molecules are quantified by the electrochemical approach in the presence of other interference species, presenting a significant challenge to researchers. In this study, molecularly imprinted polymer (MIP) was prepared using the electrochemical method in a methanol/water solution mixture. The MIP on the electrochemically reduced graphene oxide (ERGO) surface exhibited hornlike morphology in contrast to the bare GC obtained, forming irregular bulky structures with a size range of 0.8-2.1 mu m. The domperidone (DP) binding/extraction from MIP@ERGO was studied using ex situ Fourier transform infrared and X-ray photoelectron spectroscopy. The hornlike MIP@ERGO/GC revealed a higher heterogeneous electron transfer rate constant and DP antiemetic drug oxidation current response compared with the MIP/GC and non-imprinted polymer (NIP/GC) electrodes. The hornlike MIP@ERGO/GC electrode fabrication was optimized in terms of the pyrrole polymerization cyclic voltammetry cycle number, monomer/template concentration, and incubation times. The fabricated MIP@ERGO/GC electrode demonstrated a wide concentration range of DP detection (from 0.5 to 17.2 mu M), and the limit of detection was found to be 3.8 nM, with a signal-to-noise ratio of 3. Moreover, the MIP@ERGO/GC electrode had excellent DP selectivity (with an imprinting factor of 4.20), even in the presence of ascorbic acid, uric acid, dopamine, xanthine, gelatin, glucose, sucrose, t-cysteine, folic acid, K+, Na+, Ca2+, CO32-, SO42-, and NO32- interferences. The MIP@ERGO/GC electrode was tested on a human urine sample, and DP recovery ranges between 98.4% and 100.87% were obtained. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [1] Preparation of Molecularly Imprinted Polymer Sensor on Electrochemically Reduced Graphene Oxide Modified Electrode for Selective Probing of Thiabendazole
    Li, Jing
    Ma, Xiaoguo
    Zhang, Mengyuan
    Li, Danping
    Yuan, Yong
    Fan, Yinming
    Xie, Xiaowen
    Guo, Lihui
    Zeng, Guolong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (02) : B84 - B91
  • [2] Fructose determination in fruit juices using an electrosynthesized molecularly imprinted polymer on reduced graphene oxide modified electrode
    Pompeu Prado Moreira, Luiz Felipe
    Buffon, Edervaldo
    de Sa, Acelino Cardoso
    Stradiotto, Nelson Ramos
    FOOD CHEMISTRY, 2021, 352
  • [3] Molecularly imprinted polymer/graphene oxide modified glassy carbon electrode for selective detection of sulfanilamide
    Xiaobing Wei
    Xinhua Xu
    Wen Qi
    Ying Wu
    Lihong Wang
    Progress in Natural Science:Materials International, 2017, 27 (03) : 374 - 379
  • [4] Molecularly imprinted polymer/graphene oxide modified glassy carbon electrode for selective detection of sulfanilamide
    Wei, Xiaobing
    Xu, Xinhua
    Qi, Wen
    Wu, Ying
    Wang, Lihong
    PROGRESS IN NATURAL SCIENCE-MATERIALS INTERNATIONAL, 2017, 27 (03) : 374 - 379
  • [5] Sensitive and selective detection of puerarin based on the hybrid of reduced graphene oxide and molecularly imprinted polymer
    Li, Haifeng
    Wang, Shuang
    Cui, Fan
    Zhuo, Beibei
    Zhao, Chenrui
    Liu, Weilu
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 185
  • [6] A highly selective and sensitive electrochemical sensor based on graphene oxide and molecularly imprinted polymer magnetic nanocomposite for patulin determination
    Afzali, Zahra
    Mohadesi, Alireza
    Karimi, Mohammad Ali
    Fathirad, Fariba
    MICROCHEMICAL JOURNAL, 2022, 177
  • [7] Indirect voltammetric determination of nicotinic acid by using a graphite paste electrode modified with reduced graphene oxide and a molecularly imprinted polymer
    Alizadeh, Taher
    Amjadi, Somayeh
    MICROCHIMICA ACTA, 2017, 184 (08) : 2687 - 2695
  • [8] Indirect voltammetric determination of nicotinic acid by using a graphite paste electrode modified with reduced graphene oxide and a molecularly imprinted polymer
    Taher Alizadeh
    Somayeh Amjadi
    Microchimica Acta, 2017, 184 : 2687 - 2695
  • [9] A molecularly imprinted polymer on reduced graphene oxide-gold nanoparticles modified screen-printed electrode for selective determination of ferulic acid in orange peels
    Buffon, Edervaldo
    Stradiotto, Nelson Ramos
    MICROCHEMICAL JOURNAL, 2021, 167
  • [10] A Molecularly Imprinted Polymer with Incorporated Graphene Oxide for Electrochemical Determination of Quercetin
    Sun, Si
    Zhang, Mengqi
    Li, Yijun
    He, Xiwen
    SENSORS, 2013, 13 (05): : 5493 - 5506