Dielectric track detectors in fast neutron measurements and dosimetry

被引:0
|
作者
Kwiatkowski, R. [1 ]
Malinowska, A. [1 ]
Szydlowski, A. [2 ]
Dankowski, J. [3 ]
Kurowski, A. [3 ]
Gatarczyk, K. [1 ]
机构
[1] Natl Ctr Nucl Res, Soltana 7, PL-05400 Otwock, Poland
[2] Inst Plasma Phys & Laser Microfus, Hery, PL-01497 Warsaw, Poland
[3] PAN, Inst Nucl Phys, Radzikowskiego 152, PL-31342 Krakow, Poland
关键词
PADC track Detector; Neutron dosimetry; MC calculations; Neutron generator; CR-39; PARTICLE;
D O I
10.1016/j.radmeas.2020.106434
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The main aim of the presented paper was to perform neutron measurements using Solid State Nuclear Track Detectors and to compare obtained results with those obtained on the basis of Monte Carlo simulations of the experimental setup. The CR-39 type track detectors coupled with various radiators were used to measure neutrons emitted from a DT neutron generator. The detectors were also shielded with various filters made of materials characterized by low cross sections for reactions with fast neutrons. The filters were used to block charged particles with energies lower than certain threshold. The track detectors after exposure to neutrons were etched in steps, and examined using an optical microscope equipped with automatic image acquisition system. The recorded images were analyzed using a specialized software. Based on the recorded track parameters, it is also possible to calculate linear energy transfer (LET) of the registered particles, and determine the radiation dose of the emitted neutrons.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] PLASTICS AS NUCLEAR TRACK DETECTORS FOR THERMAL-NEUTRON DOSIMETRY
    FARID, SM
    SHARMA, AP
    DURRANI, SA
    PRAMANA, 1983, 20 (06) : 559 - 567
  • [12] NEUTRON DOSIMETRY WITH SOLID-STATE NUCLEAR TRACK DETECTORS
    SPURNY, F
    TUREK, K
    NUCLEAR TRACK DETECTION, 1977, 1 (3-4): : 189 - 197
  • [13] Neutron dosimetry device using PADC nuclear track detectors
    Gisela Saint Martin
    F. López
    O. A. Bernaola
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 635 - 638
  • [14] FUTURE-DEVELOPMENTS IN ETCHED TRACK DETECTORS FOR NEUTRON DOSIMETRY
    TOMMASINO, L
    RADIATION PROTECTION DOSIMETRY, 1987, 20 (1-2) : 121 - 124
  • [15] Characterization of semiconductor detectors for fast neutron beam dosimetry
    Alyousef, K
    Yudelev, M
    Burmeister, J
    Brandon, J
    Lerch, M
    Rosenfeld, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1520 - 1520
  • [16] DIELECTRIC TRACK DETECTORS AND THEIR POTENTIAL FOR USE IN NEUTRON REGISTRATION
    BELOUSOV, AV
    POLUNIN, VN
    SHCHEBET, AI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (01) : 1 - 5
  • [17] NEUTRON DOSIMETRY WITH NUCLEAR TRACK DETECTORS APPLIED TO IN-VIVO NEUTRON ACTIVATION ANALYSIS
    AGARD, ET
    JERVIS, RE
    MCNEILL, KG
    HEALTH PHYSICS, 1970, 19 (02): : 330 - +
  • [18] NEUTRON DOSIMETRY WITH NUCLEAR TRACK DETECTORS APPLIED TO IN-VIVO NEUTRON ACTIVATION ANALYSIS
    AGARD, ET
    JERVIS, RE
    MCNEILL, KG
    HEALTH PHYSICS, 1971, 21 (05): : 625 - +
  • [20] Performance Testing of the System for Analysis of PADC Track Detectors for Neutron Dosimetry
    Filova, Vendula
    Vrban, Branislav
    Cerba, Stefan
    Luley, Jakub
    Necas, Vladimir
    Dugdale, Maria
    APPLIED PHYSICS OF CONDENSED MATTER, APCOM 2022, 2023, 2778