Fully automated method for quantitative determination of steroids in serum: An approach to evaluate steroidogenesis

被引:13
|
作者
Luque-Cordoba, D. [1 ,2 ,3 ]
Priego-Capote, F. [1 ,2 ,3 ,4 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, Annex Marie Curie Bldg,Campus Rabanales, Cordoba, Spain
[2] Univ Cordoba, Nanochem Univ Inst IUNAN, Campus Rabanales, Cordoba, Spain
[3] Univ Cordoba, Reina Sofia Univ Hosp, Maimonides Inst Biomed Res IMIBIC, Cordoba, Spain
[4] Carlos III Inst Hlth, CIBERFES, Consortium Biomed Res Frailty & Hlth Ageing, Madrid, Spain
关键词
Steroids; Serum; SPE-LC-MS/MS; Steroidogenesis; Hormones; Automation; TANDEM MASS-SPECTROMETRY; SEX STEROIDS; PREMENOPAUSAL WOMEN; HORMONE LEVELS; LC-MS/MS; PLASMA; TESTOSTERONE; PROGESTERONE; DEFICIENCY; CORTISOL;
D O I
10.1016/j.talanta.2020.121923
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Steroidogenesis is a set of metabolic reactions where the enzymes play a key role to control the physiological levels of steroids. A deficiency in steroidogenesis induces an accumulation and/or insufficiency of steroids in human blood and can lead to different pathologies. This issue added to the low levels of steroids (pg mL(-1) to ng mL(-1)) in this biofluid make of their determination an analytical challenge. In this research, we present a high-throughtput and fully automated method based on solid-phase extraction on-line coupled to liquid chromatography with tandem mass spectrometry detection (SPE-LC-MS/MS) to quantify estrogens (estrone and estradiol), androgens (testosterone, androstenedione, dihydrotestosterone and dehydroepiandrosterone), progestogens (progesterone, pregnenolone, 17-hydroxyprogesterone and 17-hydroxypregnenolone), glucocorticoids (21-hydroxyprogesterone, 11-deoxycortisol, cortisone, corticosterone and cortisol) and one mineralocorticoid (aldosterone) in human serum. The performance of the SPE step and the multiple reaction monitoring (MRM) mode allowed reaching a high sensitivity and selectivity levels without any derivatization reaction. The fragmentation mechanisms of the steroids were complementary studied by LC-MS/MS in high-resolution mode to confirm the MRM transitions. The method was characterized with two SPE sorbents with similar physicochemical properties. Thus, limits of quantification were at pg mL(-1) levels, the variability was below 25% (except for pregnenolone and cortisone), and the accuracy, expressed as bias, was always within +/- 25%. The proposed method was tested in human serum from ten volunteers, who reported levels for the sixteen target steroids that were satisfactorily in agreement with the physiological ranges reported in the literature.
引用
收藏
页数:10
相关论文
共 50 条