The Effect of Repetitive Pilot-Hole Use on the Insertion Torque and Pullout Strength of Vertebral System Screws

被引:29
|
作者
Defino, Helton L. A. [1 ]
Rosa, Rodrigo Cesar [1 ]
Silva, Patricia [1 ]
Shimano, Antonio Carlos [1 ]
Volpon, Jose Batista [1 ]
Albuquerque de Paula, Francisco Jose [2 ]
Schleicher, Philipp [3 ]
Schnake, Klaus [3 ]
Kandziora, Frank [3 ]
机构
[1] Univ Sao Paulo, Dept Biomech Med & Rehabil Locomotor Apparatus, Sao Paulo, Brazil
[2] Univ Sao Paulo, Dept Internal Med, Sao Paulo, Brazil
[3] Charite Univ Med Berlin, Ctr Musculoskeletal Surg, Berlin, Germany
关键词
spine; bone screws; biomechanics; insertion torque; retentive strength; PEDICLE SCREWS; SPINAL INSTRUMENTATION; LUMBOSACRAL SPINE; LUMBAR SPINE; OUT STRENGTH; FIXATION; TESTS;
D O I
10.1097/BRS.0b013e31819e3556
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. In vitro biomechanical investigation of the screw-holding capacity. Objective. To evaluate the effect of repetitive screw-hole use on the insertional torque and retentive strength of vertebral system screws. Summary and Background Data. Placement and removal of vertebral system screws is sometimes necessary during the surgical procedures in order to assess the walls of the pilot hole. This procedure may compromise the holding capacity of the implant. Methods. Screws with outer diameter measuring 5, 6, and 7 mm were inserted into wood, polyurethane, polyethylene, and cancellous bone cylindrical blocks. The pilot holes were made with drills of a smaller, equal, or wider diameter than the inner screw diameter. Three experimental groups were established based on the number of insertions and reinsertions of the screws and subgroups were created according to the outer diameter of the screw and the diameter of the pilot hole used. Results. A reduction of screw-holding capacity was observed between the first and the following insertions regardless the anchorage material. The pattern of reduction of retentive strength was not similar to the pattern of torque reduction. The pullout strength was more pronounced between the first and the last insertions, while the torque decreased more proportionally from the first to the last insertions. Conclusion. Insertion and reinsertion of the screws of the vertebral fixation system used in the present study reduced the insertion torque and screw purchase.
引用
收藏
页码:871 / 876
页数:6
相关论文
共 21 条
  • [11] THE EFFECT OF REPETITIVE SCREW HOLE USE ON THE RETENTIVE STRENGTH OF PRETAPPED AND SELF-TAPPED SCREWS
    FOLEY, WL
    FROST, DE
    TUCKER, MR
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1990, 48 (03) : 264 - 267
  • [12] Cutting Flute and Thread Design on Self-Tapping Pedicle Screws Influence the Insertion Torque and Pullout Strength
    Wu, Lien-Chen
    Hsieh, Yueh-Ying
    Tsuang, Fon-Yih
    Kuo, Yi-Jie
    Chiang, Chang-Jung
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [13] Effect of different radial hole designs on pullout and structural strength of cannulated pedicle screws
    Chen, Hsin-Chang
    Lai, Yu Shu
    Chen, Wen-Chuan
    Chen, Jou-Wen
    Chang, Chia-Ming
    Chen, Yi-Long
    Wang, Shih-Tien
    Cheng, Cheng-Kung
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (08) : 746 - 751
  • [14] Effect of cutting flute design on cortical bone screw insertion torque and pullout strength
    Yerby, S
    Scott, CC
    Evans, NJ
    Messing, KL
    Carter, DR
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) : 216 - 221
  • [15] Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: Influences of radial hole and pilot hole tapping
    Chen, Lih-Huei
    Tai, Ching-Lung
    Lai, Po-Liang
    Lee, De-Mei
    Tsai, Tsung-Tin
    Fu, Tsai-Sheng
    Niu, Chi-Chien
    Chen, Wen-Jer
    CLINICAL BIOMECHANICS, 2009, 24 (08) : 613 - 618
  • [16] Pullout strength of cancellous screws in human femoral heads depends on applied insertion torque, trabecular bone microarchitecture and areal bone mineral density
    Ab-Lazid, Rosidah
    Perilli, Egon
    Ryan, Melissa K.
    Costi, John J.
    Reynolds, Karen J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 40 : 354 - 361
  • [17] The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models
    Patel, Purvi S. D.
    Shepherd, Duncan E. T.
    Hukins, David W. L.
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (08) : 822 - 828
  • [18] In vitro pullout strength of screws inserted in adult equine third metacarpal bone after overdrilling a 4.5-mm threaded insertion hole
    Sedrish, SA
    Moore, RM
    Kelly, K
    Martin, GS
    Burba, DJ
    VETERINARY SURGERY, 1998, 27 (02) : 143 - 149
  • [19] Effect of repeated steam sterilizations on insertional torque, torque to failure, and axial pullout strength of 3.5-mm and 2.0-mm cortical bone screws
    Yniguez, Francisco Morales
    Grimes, Janet A.
    Hodgson, Michelle M.
    Trenta, Margaret
    Liu, Chin-Chi
    Riggs, Laura M.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2024, 85 (10)
  • [20] Effect of diameter of the drill hole on torque of screw insertion and pushout strength for headless tapered compression screws in simulated fractures of the lateral condyle of the equine third metacarpal bone
    Carpenter, RS
    Galuppo, LD
    Stover, SM
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (05) : 895 - 900