Vibration & work-rate measurements of steam-generator U-tubes in air-water cross-flow

被引:0
|
作者
Janzen, VP [1 ]
Hagberg, EG [1 ]
Patrick, JNF [1 ]
Pettigrew, MJ [1 ]
Taylor, CE [1 ]
Whan, TG [1 ]
机构
[1] Atom Energy Canada Ltd, Chalk River Nucl Labs, Chalk River, ON K0J 1J0, Canada
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In nuclear power plant steam generators, the vibration response of tubes in two-phase cross-flow is a general concern that in some cases has become a very real long-term wear problem. This paper summarizes the results of the most recent U-bend vibration-response tests in a program designed to address this issue. The tests involved a simplified U-tube bundle with a set of flat-bar supports at the apex, subjected to two-phase air-water cross-flow over the mid-span region of the U-bend. Tube vibration properties and tube-to-support interaction in the form of work-rates were measured over a wide range of flow velocities for homogeneous void fractions from zero to 90%, with three different tube-to-support clearances. The measured vibration properties and work-rates could be characterized by the relative influence of the two most important flow-induced excitation mechanisms at work, fluidelastic instability and random-turbulence excitation. As in previous similar tests, strong effects of fluidelastic instability were observed at zero and 25% void fraction for pitch velocities greater than approximately 0.5 m/s, whereas random turbulence dominated the tube vibration and work-rate response at higher void fractions. In both cases, a link between vibration properties and the effect of the flat-bar supports could be established by comparing the vibration crossing frequency, extracted from time-domain vibration signals, to the participation of the lowest few vibration modes and to the measured work-rate. This approach may be useful when fluidelastic instability, random turbulence and loose supports all combine to result in high work-rates. Such a combination of factors is thought to be responsible for excessive U-tube fretting-wear in certain types of operating steam generators.
引用
收藏
页码:1019 / 1032
页数:14
相关论文
共 47 条
  • [41] Analysis of the fluid-elastic vibration of a U-bend tube bundle induced by cross-flow in PWR steam generators
    Cheng, WL
    Finnie, I
    NUCLEAR ENGINEERING AND DESIGN, 1996, 160 (1-2) : 111 - 128
  • [42] GAS-PRESSURE DROP AND LIQUID HOLDUP FOR 2-PHASE FLOW OF AIR-WATER IN CROSS-FLOW PACKED-COLUMNS
    HAYASHI, Y
    HIRAI, E
    NAKANO, Y
    URAIRI, M
    KAGAKU KOGAKU RONBUNSHU, 1988, 14 (01) : 107 - 111
  • [43] Experimental investigations on leak flow rate characteristics of water through axial artificial microcracks of steam generator tubes under back pressure conditions
    Zhang, K.
    You, H. B.
    Zhou, Y. K.
    Zhao, X. H.
    Zhang, J.
    Hou, Y. D.
    Tian, W. X.
    Su, G. H.
    Qiu, S. Z.
    NUCLEAR ENGINEERING AND DESIGN, 2019, 353
  • [44] PDA measurements of droplet size and mass flux in the three-dimensional atomisation region of water jet in air cross-flow
    Zhang, Z
    Ziada, S
    EXPERIMENTS IN FLUIDS, 2000, 28 (01) : 29 - 35
  • [45] PDA measurements of droplet size and mass flux in the three-dimensional atomisation region of water jet in air cross-flow
    Zh. Zhang
    S. Ziada
    Experiments in Fluids, 2000, 28 : 29 - 35
  • [46] STUDY ON 2-PHASE FLOW BEHAVIOR AND TURBULENT EXCITATION MECHANISM IN A U BEND TUBE BUNDLE IN STEAM-GENERATORS BASED ON AIR-WATER 2-PHASE FLOW MODEL TESTS
    YAMAGUCHI, N
    SAKATA, K
    TSUGE, A
    NAKAMURA, T
    SAITO, I
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 1993, 36 (03) : 439 - 448
  • [47] Experimental study on leak flow rate characteristics of high pressure subcooled water through axial and circumferential microcracks of steam generator tubes under high back pressure conditions
    Zhang, K.
    Shi, Y. G.
    You, H. B.
    Zhao, X. H.
    Tian, W. X.
    Su, G. H.
    Qiu, S. Z.
    ANNALS OF NUCLEAR ENERGY, 2020, 145