Determination of antimony(III) and (V) in natural water by cathodic stripping voltammetry with in-situ plated bismuth film electrode

被引:39
|
作者
Zong, Ping [1 ]
Nagaosa, Yukio [1 ]
机构
[1] Univ Fukui, Dept Appl Chem & Biotechnol, Grad Sch Engn, Bunkyo Ku, Fukui 9108507, Japan
关键词
Antimony(III); Antimony(V); Speciation analysis; Bismuth film electrode; Square wave cathodic stripping voltammetry; GENERATION; SPECIATION; COPRECIPITATION; SPECTROMETRY; ENVIRONMENT; STABILITY; SAMPLES; LEAD;
D O I
10.1007/s00604-009-0176-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the sequential determination of Sb(III) and Sb(V) using Osteryoung square wave cathodic stripping voltammetry. It employs an in-situ plated bismuth-film on an edge-plane graphite substrate as the working electrode. Selective electro-deposition of Sb(III)/Sb(V) is accomplished by applying a potential of -500 mV vs. Ag/AgCl, followed by reduction to stibine at a more negative potential in the stripping step. Stripping was carried out by applying a square wave waveform between -500 and -1400 mV to the antimony deposited. The stripping peak current at -1150 mV is directly proportional to the concentration of Sb( III)/Sb(V). The calibration plots for Sb (III) were linear up to 12.0 A mu g L-1 depending on the time of deposition. The calibration plots for Sb (V) were linear up to 7.0 A mu g L-1, also depending on the time of deposition. The relative standard deviation in the determination of 0.1 A mu g L-1 of Sb(III) is 4.0% (n = 5), and the limit of detection is as low as 2 ng L-1. In case of 0.1 A mu g L-1 Sb(V), the relative standard deviation is 3.0% (n = 5) and the detection limit also is 2 ng L-1. The method was applied to the analysis of river and sea water samples.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [21] Adsorptive stripping voltammetry of trimethoprim at an in situ plated lead film electrode
    Korolczuk, Mieczyslaw
    Tyszczuk, Katarzyna
    CHEMIA ANALITYCZNA, 2007, 52 (06): : 1015 - 1024
  • [22] Determination of Atrazine in Natural Water Samples by Differential Pulse Adsorptive Stripping Voltammetry Using a Bismuth Film Electrode
    Figueiredo-Filho, Luiz Carlos S.
    Azzi, Deborah C.
    Janegitz, Bruno C.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2012, 24 (02) : 303 - 308
  • [23] Adsorptive stripping voltammetry of nickel and cobalt at in situ plated lead film electrode
    Korolczuk, M
    Tyszczuk, K
    Grabarczyk, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2005, 7 (12) : 1185 - 1189
  • [24] Adsorptive Cathodic Stripping Voltammetric Method for Determination of Gallium Using an In Situ Plated Lead Film Electrode
    Grabarczyk, Malgorzata
    Wasag, Joanna
    ELECTROANALYSIS, 2015, 27 (11) : 2596 - 2600
  • [25] ANODIC STRIPPING VOLTAMMETRY WITH A GLASSY CARBON ELECTRODE MERCURY-PLATED IN-SITU
    FLORENCE, TM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 27 (02): : 273 - &
  • [26] TRACE DETERMINATION OF ANTIMONY AND BISMUTH IN SNOW AND WATER SAMPLES BY STRIPPING VOLTAMMETRY
    POSTUPOLSKI, A
    GOLIMOWSKI, J
    ELECTROANALYSIS, 1991, 3 (08) : 793 - 797
  • [27] Determination of Trace Chromium by Square-Wave Adsorptive Cathodic Stripping Voltammetry at an Improved Bismuth Film Electrode
    Zhang, Qing
    Zhong, Shang-wei
    Su, Jia-li
    Li, Xiang-jun
    Zou, Hong
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H237 - H242
  • [28] Determination of Folic Acid at a Bismuth Film Electrode by Adsorptive Stripping Voltammetry
    Rutyna, Iwona
    ANALYTICAL LETTERS, 2015, 48 (10) : 1593 - 1603
  • [29] Determination of cadmium(II) by square wave anodic stripping voltammetry using bismuth-antimony film electrode
    Yi, Wen Jiao
    Li, Yang
    Ran, Gu
    Luo, Hong Qun
    Li, Nian Bing
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 544 - 548
  • [30] Determination of antimony(III) and antimony(V) in copper plant electrolyte by anodic stripping voltammetry
    Bond, AM
    Kratsis, S
    Newman, OMG
    ELECTROANALYSIS, 1997, 9 (09) : 681 - 684