Wearable Detector Device with Wireless Modular Neutron Detectors and Modular Gamma-Ray Detectors

被引:0
|
作者
Ochs, T. R. [1 ]
Beatty, B. L. [4 ]
Bellinger, S. L. [2 ]
Fronk, R. G. [1 ]
Gardner, J. A. [4 ]
Henson, L. C. [2 ]
Huddleston, D. E. [3 ]
Hutchins, R. M. [1 ]
Montag, B. W. [2 ]
Sobering, T. J. [3 ]
Whitmore, L. M. [2 ]
McGregor, D. S. [1 ]
机构
[1] Kansas State Univ, Semicond Mat & Radiol Technol Lab, Manhattan, KS 66506 USA
[2] Radiat Detect Technol Inc, Manhattan, KS 66502 USA
[3] Kansas State Univ, Elect Design Lab, Manhattan, KS 66506 USA
[4] Alion Sci & Technol Corp, Mclean, VA 22102 USA
来源
2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC) | 2018年
关键词
SEMICONDUCTOR;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Sixteen Modular Neutron Detectors (MNDs) and two Modular Gamma-Ray Detectors (MGDs) were integrated into a Wearable Detector Device (WDD) for covert or overt operations regarding nuclear non-proliferation search and localization of Special Nuclear Material (SNM). Each MND contains an array of 24, 1-cm(2) active-area Microstructured Semiconductor Neutron Detectors (MSNDs) with intrinsic thermal-neutron detection efficiencies of approximately 30%. All necessary signal processing, communications, and power conditioning electronics are also housed within the MND, which measures 1.2 cm x 6.1 cm x 1.7 cm (4.4 in. x 2.4 in. x 0.65 in.). The battery within the MND allows for approximately three weeks of continuous operation on a single charge. The MGD comprises seven LND model 713 Geiger-Muller detectors, an on-board battery, and all necessary signal processing, communications, and power conditioning electronics. Each detector module interfaces with a handheld Android device through Bluetooth Low Energy communications. When the number of counts reported by the MNDs is greater than the background neutron environment, the Android device will alarm to alert the operator to the possible presence of neutron-emitting SNM. The reported count rate from the MGDs can then be used as secondary confirmation of SNM, because SNMs that emit neutrons also emit gamma rays. The neutron response of the WDD for bare Cf-252 with fluxes of 0.1, 1, and 10 n cm(-2) s(-1) measured at Pacific Northwest National Laboratory (PNNL) was 1.34 +/- 0.02, 9.93 +/- 0.01, and 99.65 +/- 0.01 cps, respectively. The corresponding neutron background count rate was 0.36 +/- 0.02 cps, significantly lower than any of the foreground count rates. When the Cf-252 source was placed in 4-cm thick, spherical HDPE moderator cask, the recorded count rate increased to 200.2 +/- 0.5 cps for 10 n cm(-2) s(-1) flux. The Gamma Absolute Rejection Ratio for neutrons (GARRn) for the WDD was measured at PNNL and was determined to be 1.02 for a neutron flux of 10 n cm(-2) s(-1) and 60(Co) gamma-ray exposure field of 10 mR/h indicating excellent gammaray rejection for the neutron detector modules. The PNNL measurement results compared well to measurements repeated at Kansas State University.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A correlation-based pulse detection technique for gamma-ray/neutron detectors
    Faisal, Muhammad
    Schiffer, Randolph T.
    Flaska, Marek
    Pozzi, Sara A.
    Wentzloff, David D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 479 - 482
  • [22] The spatial response of CdZnTe gamma-ray detectors as measured by gamma-ray mapping
    Brunett, BA
    Van Scyoc, JM
    Schlesinger, TE
    James, RB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2): : 76 - 84
  • [23] Recent Development of TlBr Gamma-Ray Detectors
    Tanaka, Tomonobu
    Hitomi, Keitaro
    Tada, Tsutomu
    Kim, Seong-Yun
    Wu, Yan
    Shoji, Tadayoshi
    Yamazaki, Hiromichi
    Ishii, Keizo
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3927 - 3931
  • [24] Recent developments in semiconductor gamma-ray detectors
    P. N. Luke
    M. Amman
    C. Tindall
    J. S. Lee
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 264 : 145 - 153
  • [25] GAMMA-RAY ENERGY DEPOSITION IN SILICON DETECTORS
    LURIE, NA
    STEINMAN, DK
    HARRIS, L
    WONDRA, JP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, 22 (06) : 2582 - 2585
  • [26] Recent Development of TlBr Gamma-Ray Detectors
    Hitomi, Keitaro
    Tada, Tsutomu
    Kim, Seong-Yun
    Wu, Yan
    Tanaka, Tomonobu
    Shoji, Tadayoshi
    Yamazaki, Hiromichi
    Ishii, Keizo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (04) : 1987 - 1991
  • [27] CdTe stacked detectors for gamma-ray detection
    Watanabe, S
    Takahashi, T
    Okada, Y
    Sato, G
    Kouda, M
    Mitani, T
    Kobayashi, Y
    Nakazawa, K
    Kuroda, Y
    Onishi, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2434 - 2438
  • [28] ELECTRON AND GAMMA-RAY SPECTROSCOPY WITH SCINTILLATION DETECTORS
    BANNERMAN, RC
    LEWIS, GM
    CURRAN, SC
    PHILOSOPHICAL MAGAZINE, 1951, 42 (333): : 1097 - 1112
  • [29] DISPERSION OF AMPLITUDE SPECTRUM OF GAMMA-RAY DETECTORS
    KATKOV, VP
    KRUPMAN, AI
    TAKSAR, IM
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1972, 5 (07): : 1214 - +
  • [30] GAMMA-RAY DETECTORS WITH HGCDTE CONTACT LAYERS
    RYAN, FJ
    SHIN, SH
    EDWALL, DD
    PASKO, JG
    KHOSHNEVISAN, M
    WESTMARK, CI
    FULLER, C
    APPLIED PHYSICS LETTERS, 1985, 46 (03) : 274 - 276