Experimental Assessment of Photon Fluence Rate Distributions in a Medium-Pressure UV Photoreactor

被引:10
|
作者
Li, Mengkai [1 ,2 ,3 ]
Qiang, Zhimin [2 ,3 ]
Wang, Chen [2 ,3 ]
Bolton, James R. [4 ]
Blatchley, Ernest R., III [1 ,5 ]
机构
[1] Purdue Univ, Lyles Sch Civil Engn, Indiana, PA 47907 USA
[2] Univ Chinese Acad Sci, Res Ctr Eco Environm Sci, Key Lab Drinking Water Sci & Technol, 18 Shuang-qing Rd, Beijing 100085, Peoples R China
[3] Chinese Acad Sci, 18 Shuang-qing Rd, Beijing 100085, Peoples R China
[4] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 2W2, Canada
[5] Purdue Univ, Div Environm & Ecol Engn, Indiana, PA 47907 USA
基金
中国国家自然科学基金;
关键词
DISINFECTION REACTORS; ANNULAR PHOTOREACTOR; CHEMICAL ACTINOMETRY; ADVANCED OXIDATION; ESCHERICHIA-COLI; WATER; OPTIMIZATION; SYSTEMS; INACTIVATION; REFLECTION;
D O I
10.1021/acs.est.6b06298
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The performance of a medium-pressure (MP) mercury lamp photoreactor is strongly influenced by the-spatial photon fluence rate (PFR) distributions which are wavelength-dependent. To address this issue, PER distributions in an MP lamp photoreactor were measured using a 360 degree response microfluorescent silica detector (MFSD), To accurately express the optical behavior in an MP photoreactor, PFR, MFSD response PFR (PFRMFSD), and effective germicidal PFR (PFRGER) were defined-and compared. The measured axial and radial PFRMFSD values agreed well with the corresponding results from a simulation model (UVCalc). The PFR and PFRGER were obtained from the measured PFRMFSD by using correction factors calculated by the UVCalc. Under identical UV transmittance (254 nm) conditions (75% and 85%), the weighted average PFRGER values were 13.3-18.7% lower than the corresponding PFR values, indicating that PFRGER, rather than PFR. should be used in MP photoreactor design to meet disinfeCtion standards. Based on measured lamp output, medium absorption spectrum, MFSD response, and microbial DNA response spectrum, the detailed relationships between the PFR, PFRMFSD, and PFRGER were elucidated. This work proposes a new method for the accurate description of wavelength-dependent PFR distributions in MP photoreactors, thus providing an important tool for the optimal-design of these systems.
引用
收藏
页码:3453 / 3460
页数:8
相关论文
共 50 条
  • [41] Emerging investigator series: rapid defluorination of 22 per- and polyfluoroalkyl substances in water using sulfite irradiated by medium-pressure UV
    Abusallout, Ibrahim
    Wang, Junli
    Hanigan, David
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2021, 7 (09) : 1552 - 1562
  • [42] Experimental assessment of neutron fluence for the Kozloduy Unit 1 pressure vessel by scraps and cavity dosimetry
    Apostolov, T
    Ilieva, K
    Belousov, S
    Petrova, T
    Penev, I
    Popova, I
    Antonov, S
    NUCLEAR ENGINEERING AND DESIGN, 1998, 186 (03) : 361 - 368
  • [43] EXPERIMENTAL STUDY ON PERFORMANCE OF MEDIUM-PRESSURE AIR-SUPPLY HEAT PUMP AIR CONDITIONING SYSTEM FOR PURE ELECTRIC BUS
    Li, Haijun
    Su, Zhiyong
    Liu, Enhai
    Shi, Shuanling
    Zhang, Zhonglai
    Yu, Zhuang
    Han, Chuang
    Bai, Junqin
    Fan, Yuehua
    Fan, Ya
    Wang, Chunyan
    THERMAL SCIENCE, 2021, 25 (03): : 2303 - 2309
  • [44] Experimental and model comparisons of low- and medium-pressure Hg lamps for the direct and H2O2 assisted UV photodegradation of N-nitrosodimethylamine in simulated drinking water
    Sharpless, CM
    Linden, KG
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (09) : 1933 - 1940
  • [45] Photo-oxidation of 11-nor-9-carboxy-△9-tetrahydrocannabinol using medium-pressure UV and UV/H2O2 - a kinetic study
    Park, Yuri
    Mackie, Allison L.
    MacIsaac, Sean A.
    Gagnon, Graham A.
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2018, 4 (09) : 1262 - 1271
  • [46] Comparative research of efficiency of water decontamination by UV radiation of cold hollow cathode discharge plasma versus that of low- and medium-pressure mercury lamps
    Soloshenko, I. A.
    Bazhenov, V. Yu.
    Khomich, V. A.
    Tsiolko, V. V.
    Potapchenko, N. G.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (04) : 1365 - 1369
  • [47] Evaluation of the Effect of Using the UV + O3 Process with Low- and Medium-Pressure Lamps on the Amount and Properties of Organic Substances in Treated Water
    Wolska, Malgorzata
    Kabsch-Korbutowicz, Malgorzata
    Solipiwko-Piescik, Anna
    Sperczynska, Elzbieta
    WATER, 2025, 17 (05)
  • [48] Meta-analysis of the reduction of antibiotic-sensitive and antibiotic-resistant Escherichia coli as a result of low- and medium-pressure UV lamps
    O'Flaherty, Eithne
    Membre, Jeanne-Marie
    Cummins, Enda
    WATER SCIENCE AND TECHNOLOGY, 2018, (02) : 612 - 620
  • [49] EFFECTS OF PHOTON FLUENCE RATE AND INTERCELLULAR CO2 PARTIAL-PRESSURE ON LEAF CONDUCTANCE AND CO2 UPTAKE RATE IN CAPSICUM AND AMARANTHUS
    RAMOS, C
    HALL, AE
    PHOTOSYNTHETICA, 1983, 17 (01) : 34 - 42
  • [50] A comparison of DNA repair and survival of Escherichia coli O157:H7 following exposure to both low- and medium-pressure UV irradiation
    Zimmer-Thomas, J. L.
    Slawson, R. M.
    Huck, P. M.
    JOURNAL OF WATER AND HEALTH, 2007, 5 (03) : 407 - 415