Investigation of the spectral improvement of a capacitive Frisch-grid CdZnTe detector by using infrared stimulation

被引:3
|
作者
Yang, Guoqiang [1 ]
Xiao, Shali [1 ]
Ma, Yuedong [1 ]
Zhang, Liuqiang [1 ]
机构
[1] Chongqing Univ, Key Lab Optoelect Technol & Syst, Minist Educ, Chongqing 400044, Peoples R China
基金
中国国家自然科学基金;
关键词
Capacitive Frisch grid; CdZnTe detector; Energy resolution; Infrared stimulation; GAMMA-RAY SPECTROSCOPY; RADIATION DETECTOR; CARRIER COLLECTION; CHARGE;
D O I
10.3938/jkps.65.441
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A capacitive Frisch-grid CdZnTe detector with different lengths of the Frisch rings has been fabricated, and the influence of infrared (IR) stimulation on the spectral performance of the detector has been investigated. IR stimulation at a wavelength (940 nm), close to the absorption edge of the CdZnTe, was found to improve the detector's spectral performance significantly. IR radiation was noted to influence the detector's sensitivity, changing the equilibrium between free and trapped carriers and improving the charge collection. The degree of improvement was different for detectors with different lengths of the Frisch rings and depended on the weighting potential distribution and the IR illumination intensity. For example, improvement was obtained in the energy resolution (FWHM) at 662 keV from 3.3% without illumination to 2.3% with a low intensity (120 mu W) of IR illumination for the capacitive Frisch-grid CdZnTe detector with an 8-mm-long Frisch ring. Good energy resolution could be obtained even at low operating voltages.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 50 条
  • [21] Spectral responses of virtual Frisch-grid CdZnTe detectors and their relation to IR microscopy and X-ray diffraction topography data
    Bolotnikov, A. E.
    Babalola, S.
    Camarda, G. S.
    Cui, Y.
    Egarievwe, S. U.
    Fochuk, P. M.
    Hawrami, R.
    Hossain, A.
    James, J. R.
    Nakonechnyj, I. J.
    Yang, Ge
    James, R. B.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [22] Optimizing CdZnTeSe Frisch-Grid Nuclear Detector for Gamma-Ray Spectroscopy
    Egarievwe, Stephen U.
    Roy, Utpal N.
    Agbalagba, Ezekiel O.
    Harrison, Benicia A.
    Goree, Carmella A.
    Savage, Emmanuel K.
    James, Ralph B.
    IEEE ACCESS, 2020, 8 : 137530 - 137539
  • [23] Use of Virtual Frisch-Grid CdZnTe Detectors to Attain Sub-millimeter Spatial Resolution
    Lee, Kisung
    Bolotnikov, Aleksey
    Bae, Seungbin
    Roy, Utpal
    Camarda, Giuseppe
    Petryk, Matthew
    Cui, Yonggang
    Hossain, Anwar
    Yang, Ge
    Dedic, Vaclav
    Kim, Kihyun
    James, Ralph
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [24] Research on the electron attachment of oxygen using a Frisch-grid ionization chamber
    Liu, Jie
    Jiang, Haoyu
    Cui, Zengqi
    Hu, Yiwei
    Bai, Haofan
    Chen, Jinxiang
    Zhang, Guohui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1013
  • [25] A linear array of position-sensitive virtual Frisch-grid CdZnTe for low-energy gamma rays
    Giraldo, L. Ocampo
    Bolotnikov, A. E.
    Camarda, G. S.
    De Geronimo, G.
    Fried, J.
    Hodges, D.
    Hossain, A.
    Vernon, E.
    James, R. B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 903 : 204 - 214
  • [26] A twin Frisch-grid ionization chamber as a selective detector for the delayed gamma-spectroscopy of fission fragments
    Gaudefroy, L.
    Roger, T.
    Pancin, J.
    Spitaels, C.
    Aupiais, J.
    Mottier, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 855 : 133 - 139
  • [27] Arrays of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors: Results From a 4 x 4 Array Prototype
    Giraldo, L. A. Ocampo
    Bolotnikov, A. E.
    Camarda, G. S.
    Cheng, S.
    De Geronimo, G.
    McGilloway, A.
    Fried, J.
    Hodges, D.
    Hossain, A.
    Unlu, K.
    Petryk, M.
    Vidal, V.
    Vernon, E.
    Yang, G.
    James, R. B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (10) : 2698 - 2705
  • [28] A method for measuring the electron drift velocity in working gas using a Frisch-grid ionization chamber
    Bai, Huaiyong
    Wang, Zhimin
    Zhang, Luyu
    Chen, Jimdang
    Zhang, Guohui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 840 : 36 - 41
  • [29] Improved method to measure the electron drift velocity using the Frisch-grid ionization chamber
    Liu, Jie
    Jiang, Haoyu
    Cui, Zengqi
    Hu, Yiwei
    Chen, Jinxiang
    Zhang, Guohui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1004
  • [30] Characteristics of a Frisch collar grid CdZnTe radiation detector grown by low-pressure Bridgman method
    Manhee Jeong
    Woo Jin Jo
    Han Soo Kim
    Jang Ho Ha
    Journal of the Korean Physical Society, 2015, 66 : 1669 - 1674