Normothermic ex vivo lung perfusion of non-heart-beating donor lungs in pigs:: from pretransplant function analysis towards a 6-h machine preservation

被引:52
|
作者
Erasmus, ME
Fernhout, MH
Elstrodt, JM
Rakhorst, G
机构
[1] Univ Groningen, Ctr Med, Dept Cardiothorac Surg, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Ctr Med, Dept Anaesthesiol, Groningen, Netherlands
[3] Univ Groningen, Ctr Med, Dept Biomed Engn, Groningen, Netherlands
关键词
ex vivo lung perfusion; lung preservation; machine preservation; non-heart-beating lung donation;
D O I
10.1111/j.1432-2277.2006.00318.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Donor shortage urges optimal use of all lungs available. Ex vivo lung perfusion (EVLP) is a method to evaluate lung function before implantation. EVLP was performed in pigs to evaluate lung function, using two different clinical non-heart-beating (NHS) donor protocols: flush perfusion and topical cooling after 1-h warm ischaemia (n = 5 each). Secondly, we investigated whether EVLP can be used for 6 h ex vivo machine preservation (n = 4). In comparison with topical cooling, flush perfusion preserved lung function better during EVLP. During 6 h normothermic EVLP, gas exchange remained stable; however, the pulmonary artery pressure and ventilation pressure showed a significant increase. EVLP is a reliable method for evaluation of lung graft function. Flush perfusion with Perfadex is preferred above topical cooling in NHB lung donation. Six-hour normothermic EVLP is feasible but should be further improved to make ex vivo machine preservation or treatment of lung grafts successful.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 50 条
  • [41] Recovery of energy stores and mitochondrial function of hypothermic machine perfusion preserved non-heart-beating donor rat livers.
    Lee, CY
    Duncan, HM
    Jain, S
    Zhang, JX
    Jones, JW
    Southard, JH
    Clemens, MG
    HEPATOLOGY, 2003, 38 (04) : 476A - 476A
  • [42] Preservation of non-heart-beating donor kidneys:: A clinical prospective randomised case-control study of machine perfusion versus cold storage
    van der Vliet, JA
    Kievit, JK
    Héné, RJ
    Hilbrands, LB
    Kootstra, G
    TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) : 847 - 847
  • [43] Time-Course Microarray Analysis of Rejected Human Donor Lungs during 12 Hours of Acellular Normothermic Ex Vivo Lung Perfusion
    Yeung, J. C.
    Boutros, P. C.
    Zamel, R.
    Cypel, M.
    Bai, X. -H.
    Matsuda, Y.
    Waddell, T. K.
    Liu, M.
    Keshavjee, S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2012, 31 (04): : S106 - S107
  • [44] Long-term preservation with interim evaluation of lungs from a non-heart-beating donor after a warm ischemic interval of 90 minutes
    Rega, FR
    Jannis, NC
    Verleden, GM
    Lerut, TE
    Van Raemdonck, DEM
    ANNALS OF SURGERY, 2003, 238 (06) : 782 - 792
  • [45] CONTINUOUS NORMOTHERMIC EX VIVO KIDNEY PERFUSION IS SAFE IN HEART BEATING DONOR KIDNEY TRANSPLANTATION AND IMPROVES RENAL GRAFT FUNCTION IN DONATION AFTER CIRCULATORY DEATH
    Kaths, J. M.
    Echeverri, J.
    Linares, I.
    Hamar, M.
    Cen, J. Y.
    Ganesh, S.
    Yip, P. M.
    John, R.
    Bagli, D.
    Mucsi, I.
    Ghanekar, A.
    Grant, D.
    Robinson, L.
    Selzner, M.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 46 - 47
  • [46] Long-term preservation with interim evaluation of lungs from a non-heart-beating donor after a warm ischemic interval of 90 minutes - Discussion
    Clavien, PA
    Rega, F
    Morris, PJ
    Ploeg, RJ
    Friend, PJ
    ANNALS OF SURGERY, 2003, 238 (06) : 792 - 793
  • [47] Maintenance of physiological coronary endothelial function after 3.3 h of hypothermic oxygen persufflation preservation and orthotopic transplantation of non-heart-beating donor hearts
    Fischer, JH
    Funcke, C
    Yotsumoto, G
    Jeschkeit-Schubbert, S
    Kuhn-Régnier, F
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 25 (01) : 98 - 104
  • [48] Kidney transplantation from non-heart-beating donors after oxygenated low-flow machine perfusion preservation with histidine-tryptophan-ketoglutarate solution
    Minor, T
    Sitzia, M
    Dombrowski, F
    TRANSPLANT INTERNATIONAL, 2004, 17 (11) : 707 - 712
  • [49] SUBNORMOTHERMIC MACHINE PERFUSION REDUCES PRESERVATION DAMAGE OF LIVERS FROM NON-HEART BEATING DONORS: A NEW CHANGE FOR EXPANDING THE DONOR POOL?
    Ferrigno, A.
    Rizzo, V.
    Bonconpagni, E.
    Richelmi, P.
    Neri, D.
    Gringen, E.
    Freitas, I.
    Cillo, U.
    Vairetti, M.
    JOURNAL OF HEPATOLOGY, 2009, 50 : S66 - S67
  • [50] Ex vivo subnormothermic oxygenated liver perfusion just before liver transplantation from non-heart-beating donors might improve graft viability, in pig model
    Kakizaki, Yuta
    Miyagi, Shigehito
    Shimizu, Kenji
    Kumata, Hiroyuki
    Matsumura, Muneyuki
    Miyazaki, Yuki
    Fukuoka, Kengo
    Uematsu, Satomi Suzuki
    Hara, Yasuyuki
    Nakanishi, Chikashi
    Kawagishi, Naoki
    Ohuchi, Noriaki
    TRANSPLANTATION, 2016, 100 (07) : S146 - S147