Normothermic ex vivo lung perfusion of non-heart-beating donor lungs in pigs:: from pretransplant function analysis towards a 6-h machine preservation

被引:52
|
作者
Erasmus, ME
Fernhout, MH
Elstrodt, JM
Rakhorst, G
机构
[1] Univ Groningen, Ctr Med, Dept Cardiothorac Surg, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen, Ctr Med, Dept Anaesthesiol, Groningen, Netherlands
[3] Univ Groningen, Ctr Med, Dept Biomed Engn, Groningen, Netherlands
关键词
ex vivo lung perfusion; lung preservation; machine preservation; non-heart-beating lung donation;
D O I
10.1111/j.1432-2277.2006.00318.x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Donor shortage urges optimal use of all lungs available. Ex vivo lung perfusion (EVLP) is a method to evaluate lung function before implantation. EVLP was performed in pigs to evaluate lung function, using two different clinical non-heart-beating (NHS) donor protocols: flush perfusion and topical cooling after 1-h warm ischaemia (n = 5 each). Secondly, we investigated whether EVLP can be used for 6 h ex vivo machine preservation (n = 4). In comparison with topical cooling, flush perfusion preserved lung function better during EVLP. During 6 h normothermic EVLP, gas exchange remained stable; however, the pulmonary artery pressure and ventilation pressure showed a significant increase. EVLP is a reliable method for evaluation of lung graft function. Flush perfusion with Perfadex is preferred above topical cooling in NHB lung donation. Six-hour normothermic EVLP is feasible but should be further improved to make ex vivo machine preservation or treatment of lung grafts successful.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 50 条
  • [1] Reconditioning of Lungs from Non-Heart-Beating Donors with Normothermic Ex Vivo Lung Perfusion
    Nakajima, D.
    Yamada, T.
    Chen, F.
    Sakamoto, J.
    Ohsumi, A.
    Fujinaga, T.
    Shoji, T.
    Sakai, H.
    Bando, T.
    Date, H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (04): : S38 - S39
  • [2] Extended preservation of non-heart-beating donor livers with normothermic machine perfusion
    St Peter, SD
    Imber, CJ
    Lopez, I
    Hughes, D
    Friend, PJ
    BRITISH JOURNAL OF SURGERY, 2002, 89 (05) : 609 - 616
  • [3] Ex vivo rehabilitation of non-heart-beating donor lungs in preclinical porcine model: Delayed perfusion results in superior lung function
    Mulloy, Daniel P.
    Stone, Matthew L.
    Crosby, Ivan K.
    Lapar, Damien J.
    Sharma, Ashish K.
    Webb, David V.
    Lau, Christine L.
    Laubach, Victor E.
    Kron, Irving L.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (05): : 1208 - 1216
  • [4] The effect of machine perfusion preservation on early function of non-heart-beating donor kidneys
    Daemen, JHC
    de Vries, B
    Kootstra, G
    TRANSPLANTATION PROCEEDINGS, 1997, 29 (08) : 3489 - 3489
  • [5] Establishment of an Ex Vivo Lung Perfusion Model Using Non-Heart-Beating Large Pigs
    Okamoto, T.
    Chen, F.
    Zhang, J.
    Yamada, T.
    Nakayama, E.
    Morikawa, H.
    Bando, T.
    Date, H.
    TRANSPLANTATION PROCEEDINGS, 2010, 42 (05) : 1598 - 1601
  • [6] The Effects of Hydrogen Gas Inhalation On Non-Heart-Beating Donor Lung During Ex Vivo Lung Perfusion
    Paik, H.
    Haam, S.
    Park, M.
    Song, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2014, 14 : 376 - 377
  • [7] Hypothermic machine perfusion preservation of non-heart-beating donor pancreas for islet transplantation
    Akutsu, Naotake
    Ishida, Takemichi
    Maruyama, Michihiro
    Otsuki, Kazunori
    Saitoh, Tomonori
    Saigo, Kenichi
    Hasegawa, Masayuki
    Aoyama, Hiromichi
    Matsumoto, Ikuko
    Kenmochi, Takashi
    Noguchi, Hirofumi
    TRANSPLANTATION, 2016, 100 (07) : S63 - S63
  • [8] The Effects of Hydrogen Gas Inhalation On Non-Heart-Beating Donor Lung During Ex Vivo Lung Perfusion.
    Paik, H.
    Haam, S.
    Park, M.
    Song, J.
    TRANSPLANTATION, 2014, 98 : 376 - 377
  • [9] Ex-vivo perfusion and ventilation of rat lungs from non-heart-beating donors before transplant
    Inokawa, Hidetoshi
    Sevala, Mayura
    Funkhouser, William K.
    Egan, Thomas M.
    ANNALS OF THORACIC SURGERY, 2006, 82 (04): : 1219 - 1225
  • [10] Effect of machine perfusion preservation on delayed graft function in non-heart-beating donor kidneys early results
    Daemen, JHC
    deVries, B
    Oomen, APA
    DeMeester, J
    Kootstra, G
    TRANSPLANT INTERNATIONAL, 1997, 10 (04) : 317 - 322