Validation of Bioelectrical Impedance Spectroscopy to Measure Total Body Water in Resistance-Trained

被引:27
|
作者
Kerr, Ava [1 ]
Slater, Gary [1 ]
Byrne, Nuala [2 ]
Chaseling, Janet [3 ]
机构
[1] Univ Sunshine Coast, Sch Hlth & Sport Sci, Sippy Downs, Qld, Australia
[2] Bond Univ, Fac Hlth Sci & Med, Southport, Qld 4229, Australia
[3] Griffith Univ, Griffith Sch Environm, Nathan, Qld 4111, Australia
关键词
deuterium dilution; total body water; bioelectrical impedance spectroscopy; body fat percentage; BIOIMPEDANCE SPECTROSCOPY; 4-COMPARTMENT MODELS; DEUTERIUM DILUTION; FAT; WOMEN; MEN; OVERWEIGHT; FREQUENCY; AGREEMENT; VOLUMES;
D O I
10.1123/ijsnem.2014-0188
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The three-compartment (3-C) model of physique assessment (fat mass, fat-free mass, water) incorporates total body water (TBW) whereas the two-compartment model (2-C) assumes a TBW of 73.72%. Deuterium dilution (D2O) is the reference method for measuring TBW but is expensive and time consuming. Multi-frequency bioelectrical impedance spectroscopy (BIS SFB7) estimates TBW instantaneously and claims high precision. Our aim was to compare SFB7 with D2O for estimating TBW in resistance trained males (BMI >25kg/m(2)). We included TBWBIS estimates in a 3-C model and contrasted this and the 2-C model against the reference 3-C model using TBWD2O. TBW of 29 males (32.4 +/- 8.5 years; 183.4 +/- 7.2 cm; 92.5 +/- 9.9 kg; 27.5 +/- 2.6 kg/m(2)) was measured using SFB7 and D2O. Body density was measured by BODPOD, with body composition calculated using the Sini equation. TBWBIS values were consistent with TBWD2O (SEE = 2.65L; TE = 2.6L) as were %BF values from the 3-C model (BODPOD + TBWBB) with the 3-C reference model (SEE = 2.20%; TE = 2.20%). For subjects with TBW more than 1% from the assumed 73.72% (n = 16), %BF from the 2-C model differed significantly from the reference 3-C model (Slope 0.6888; Intercept 5.093). The BIS SFB7 measured TBW accurately compared with D2O. The 2C model with an assumed TBW of 73.72% introduces error in the estimation of body composition. We recommend TBW should be measured, either via the traditional D2O method or when resources are limited, with BIS, so that body composition estimates are enhanced. The BIS can be accurately used in 3C equations to better predict TBW and BF% in resistance trained males compared with a 2C model.
引用
收藏
页码:494 / 503
页数:10
相关论文
共 50 条
  • [21] Validation of bioelectrical impedance analysis for total body water assessment against the deuterium dilution technique in Asian children
    A Liu
    N M Byrne
    G Ma
    L Nasreddine
    T P Trinidad
    K Kijboonchoo
    M N Ismail
    M Kagawa
    B K Poh
    A P Hills
    European Journal of Clinical Nutrition, 2011, 65 : 1321 - 1327
  • [22] Extracellular water and total body water estimated by multifrequency bioelectrical impedance analysis in healthy cats: A cross-validation study
    Elliott, DA
    Backus, RC
    Van Loan, MD
    Rogers, QR
    JOURNAL OF NUTRITION, 2002, 132 (06): : 1760S - 1762S
  • [23] PREDICTING TOTAL-BODY WATER FROM BIOELECTRICAL IMPEDANCE IN CHILDREN - REPLY
    DAVIES, PSW
    ANNALS OF HUMAN BIOLOGY, 1989, 16 (02) : 174 - 174
  • [24] The prediction of total body water from bioelectrical impedance in patients with anorexia nervosa
    Scalfi, L
    Bedogni, G
    Marra, M
    DiBiase, G
    Caldara, A
    Severi, S
    Contaldo, F
    Battistini, N
    BRITISH JOURNAL OF NUTRITION, 1997, 78 (03) : 357 - 365
  • [25] Assessment of bioelectrical impedance analysis for the prediction of total body water in cystic fibrosis
    Richards, ML
    Bell, SC
    Edmiston, KA
    Davies, PSW
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2003, 12 (02) : 161 - 165
  • [26] THE PREDICTION OF TOTAL-BODY WATER USING BIOELECTRICAL IMPEDANCE IN CHILDREN AND ADOLESCENTS
    DAVIES, PSW
    PREECE, MA
    HICKS, CJ
    HALLIDAY, D
    ANNALS OF HUMAN BIOLOGY, 1988, 15 (03) : 237 - 240
  • [27] Approaches at Increasing the Accuracy of Bioelectrical Impedance-Derived Total Body Water
    Cataldi, Devon
    Bennett, Jon
    Quon, Brandon
    Liu, En Yong
    Heymsfield, Steven
    Schoeller, Dale
    Kelly, Tom
    Shepherd, John
    OBESITY, 2021, 29 : 58 - 58
  • [28] A new approach to estimate changes in total body water by bioelectrical impedance analysis
    Lukaski, HC
    NUTRITION, 1997, 13 (05) : 474 - 475
  • [29] TOTAL-BODY WATER IN PREGNANCY - ASSESSMENT BY USING BIOELECTRICAL-IMPEDANCE
    LUKASKI, HC
    SIDERS, WA
    NIELSEN, EJ
    HALL, CB
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1994, 59 (03): : 578 - 585
  • [30] Bioelectrical impedance analysis as a means of estimating total body water in grey seals
    Bowen, WD
    Beck, CA
    Iverson, SJ
    CANADIAN JOURNAL OF ZOOLOGY-REVUE CANADIENNE DE ZOOLOGIE, 1999, 77 (03): : 418 - 422