Validation of Bioelectrical Impedance Spectroscopy to Measure Total Body Water in Resistance-Trained

被引:27
|
作者
Kerr, Ava [1 ]
Slater, Gary [1 ]
Byrne, Nuala [2 ]
Chaseling, Janet [3 ]
机构
[1] Univ Sunshine Coast, Sch Hlth & Sport Sci, Sippy Downs, Qld, Australia
[2] Bond Univ, Fac Hlth Sci & Med, Southport, Qld 4229, Australia
[3] Griffith Univ, Griffith Sch Environm, Nathan, Qld 4111, Australia
关键词
deuterium dilution; total body water; bioelectrical impedance spectroscopy; body fat percentage; BIOIMPEDANCE SPECTROSCOPY; 4-COMPARTMENT MODELS; DEUTERIUM DILUTION; FAT; WOMEN; MEN; OVERWEIGHT; FREQUENCY; AGREEMENT; VOLUMES;
D O I
10.1123/ijsnem.2014-0188
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
The three-compartment (3-C) model of physique assessment (fat mass, fat-free mass, water) incorporates total body water (TBW) whereas the two-compartment model (2-C) assumes a TBW of 73.72%. Deuterium dilution (D2O) is the reference method for measuring TBW but is expensive and time consuming. Multi-frequency bioelectrical impedance spectroscopy (BIS SFB7) estimates TBW instantaneously and claims high precision. Our aim was to compare SFB7 with D2O for estimating TBW in resistance trained males (BMI >25kg/m(2)). We included TBWBIS estimates in a 3-C model and contrasted this and the 2-C model against the reference 3-C model using TBWD2O. TBW of 29 males (32.4 +/- 8.5 years; 183.4 +/- 7.2 cm; 92.5 +/- 9.9 kg; 27.5 +/- 2.6 kg/m(2)) was measured using SFB7 and D2O. Body density was measured by BODPOD, with body composition calculated using the Sini equation. TBWBIS values were consistent with TBWD2O (SEE = 2.65L; TE = 2.6L) as were %BF values from the 3-C model (BODPOD + TBWBB) with the 3-C reference model (SEE = 2.20%; TE = 2.20%). For subjects with TBW more than 1% from the assumed 73.72% (n = 16), %BF from the 2-C model differed significantly from the reference 3-C model (Slope 0.6888; Intercept 5.093). The BIS SFB7 measured TBW accurately compared with D2O. The 2C model with an assumed TBW of 73.72% introduces error in the estimation of body composition. We recommend TBW should be measured, either via the traditional D2O method or when resources are limited, with BIS, so that body composition estimates are enhanced. The BIS can be accurately used in 3C equations to better predict TBW and BF% in resistance trained males compared with a 2C model.
引用
收藏
页码:494 / 503
页数:10
相关论文
共 50 条
  • [1] Validation of Bioelectrical Impedance Against Tracers for Total Body and Extracellular Water
    Sanchez, Gabriel
    Courville, Amber
    Brychta, Robert
    Lamunion, Samuel
    Davis, Kyndall
    Jordan, Olivia
    Ishihara, Asuka
    Chen, Kong
    OBESITY, 2024, 32 : 277 - 278
  • [2] Body composition in elite athletes -: validation of bioelectrical impedance spectroscopy
    Slinde, Frode
    Klingberg, Sofia
    Johansson, Hanna
    Zander, Martina
    Hulthen, Lena
    Svantesson, Ulla
    ANNALS OF NUTRITION AND METABOLISM, 2007, 51 : 291 - 291
  • [3] CAN BIOELECTRICAL-IMPEDANCE BE USED TO MEASURE TOTAL-BODY WATER IN DIALYSIS PATIENTS
    THOMPSON, CM
    KONG, CH
    LEWIS, CA
    HILL, PD
    THOMPSON, FD
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 (04) : 455 - 461
  • [4] Use of bioelectrical impedance spectroscopy to provide a measure of body composition in sows
    Muller, T. L.
    Ward, L. C.
    Plush, K. J.
    Pluske, J. R.
    D'Souza, D. N.
    Bryden, W. L.
    van Barneveld, R. J.
    ANIMAL, 2021, 15 (03)
  • [5] Is bioelectrical impedance spectroscopy accurate in estimating total body water and its compartments in elite athletes?
    Matias, Catarina N.
    Santos, Diana A.
    Goncalves, Ezequiel M.
    Fields, David A.
    Sardinha, Luis B.
    Silva, Analiza M.
    ANNALS OF HUMAN BIOLOGY, 2013, 40 (02) : 152 - 156
  • [6] ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS
    KUSHNER, RF
    SCHOELLER, DA
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03): : 417 - 424
  • [7] Evaluation of Bioelectrical Impedance Spectroscopy for the Assessment of Extracellular Body Water
    Weyer, Soeren
    Roethlingshoefer, Lisa
    Walter, Marian
    Leonhardt, Steffen
    ACTA POLYTECHNICA, 2012, 52 (05) : 120 - 124
  • [8] USE OF BIOELECTRICAL IMPEDANCE ANALYSIS TO MEASURE TOTAL-BODY WATER IN PATIENTS WITH CYSTIC-FIBROSIS
    AZCUE, M
    FRIED, M
    PENCHARZ, PB
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 1993, 16 (04): : 440 - 445
  • [9] MULTIFREQUENCY BIOELECTRICAL IMPEDANCE AS A MEASURE OF DIFFERENCES IN BODY-WATER DISTRIBUTION
    LUSSEVELD, EM
    PETERS, ETJ
    DEURENBERG, P
    ANNALS OF NUTRITION AND METABOLISM, 1993, 37 (01) : 44 - 51
  • [10] Bioelectrical impedance spectroscopy and body composition
    Chumlea, WC
    Siervogel, RM
    Wu, YX
    Hall, G
    Guo, SS
    IN VIVO BODY COMPOSITION STUDIES, 2000, 904 : 210 - 213