Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents

被引:9
|
作者
Glowinska-Olszewska, B. [1 ]
Tobiaszewska, M. [1 ]
Luczynski, W. [1 ]
Bossowski, A. [1 ]
机构
[1] Med Univ Bialystok, Dept Paediat, Div Cardiol, PL-15274 Bialystok, Poland
来源
ADVANCES IN MEDICAL SCIENCES | 2013年 / 58卷 / 02期
关键词
diabetes type 1; adolescents; real-time continuous glucose monitoring; metabolic control; education; IMPROVED GLYCEMIC CONTROL; SENSOR-AUGMENTED PUMP; PEDIATRIC-PATIENTS; PROLONGED USE; CHILDREN; THERAPY; HYPOGLYCEMIA; VARIABILITY; LIFE;
D O I
10.2478/ams-2013-0024
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Purpose: Experience with the use of real-time continuous glucose monitoring systems (RT-CGMS) in teenagers with type 1 diabetes mellitus (T1DM) is limited. We aimed to assess the possibility of glycaemic control improvement and to characterize the group of adolescents, who may gain long-term benefits from the use of the RT-CGMS. Methods: Forty T1DM patients, aged 14.6 +/- 2.1 years, with diabetes duration 7.4 +/- 3.6 years and initial HbA(1)c 9.3 +/- 1.5% were recruited. The analysis was based on one-month glucose sensors use, combined with the thorough family support. Patients were analysed in groups according to baseline HbA(1)c: below and above 7.5%, and 10.0%. Comparison between patients with or without improvement in HbA(1)c after 3-month follow-up was also performed. Patients' satisfaction based on the questionnaire was assessed. Results: HbA(1)c level in entire study group decreased after three months, from 9.3 +/- 1.0% to 8.8 +/- 1.6% (P<0.001). In the group with HbA(1)c improvement, reduction was the highest: 9.0 +/- 1.3% vs. 8.0 +/- 1.2% (P<0.001). Only the group with initial HbA(1)c>10% did not achieve significant improvement: 11.2 +/- 0.5% vs. 10.9 +/- 1.1 (P=0.06). In satisfaction questionnaire the lowest scores (negative opinion) were reported by group of patients with initial HbA(1)c above 10%, while the highest scores (positive opinion) were found in the group with improvement of HbA(1)c after 3 month follow-up. Conclusion: Short-term use of CGMS RT, united with satisfaction questionnaire, performed in poorly controlled teenagers with T1DM, can be useful in defining the group of young patients, who can benefit from long-term CGMS RT use in metabolic control improvement.
引用
收藏
页码:344 / 352
页数:9
相关论文
共 50 条
  • [21] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    I. Dicembrini
    C. Cosentino
    M. Monami
    E. Mannucci
    L. Pala
    Acta Diabetologica, 2021, 58 : 401 - 410
  • [22] Effects of real-time continuous glucose monitoring in type 1 diabetes: a meta-analysis of randomized controlled trials
    Dicembrini, I.
    Cosentino, C.
    Monami, M.
    Mannucci, E.
    Pala, L.
    ACTA DIABETOLOGICA, 2021, 58 (04) : 401 - 410
  • [23] Caregivers of Children with Type 1 Diabetes Value Real-Time Functions of Continuous Glucose Monitoring
    Wong, Jenise C.
    Abdulhussein, Fatema
    Yeung, Brittany J.
    Velazquez, Edgar J.
    DIABETES, 2019, 68
  • [24] Effect of real-time continuous glucose monitoring on hypoglycemia in adult type 1 diabetes patients
    Jia, Weiping
    JOURNAL OF DIABETES INVESTIGATION, 2018, 9 (03): : 478 - 480
  • [25] The accuracy and efficacy of Real-Time Continuous Glucose Monitoring sensor in patients with type 1 diabetes
    Mastrototaro, John
    Shin, John
    Marcus, Alan
    Sulur, Giri
    DIABETES TECHNOLOGY & THERAPEUTICS, 2008, 10 (05) : 385 - 390
  • [26] Measures of Glycemic Variability in Type 1 Diabetes and the Effect of Real-Time Continuous Glucose Monitoring
    El-Laboudi, Ahmed H.
    Godsland, Ian F.
    Johnston, Desmond G.
    Oliver, Nick S.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (12) : 806 - 812
  • [27] RETROSPECTIVE VS REAL-TIME CONTINUOUS GLUCOSE MONITORING IN TYPE 1 DIABETES: WHICH IS BETTER?
    Petrovski, G.
    Zivkovic, M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : A86 - A86
  • [28] Performance of real-time continuous glucose monitoring during 4 weeks of track and field training in adolescents with type 1 diabetes
    Schierbauer, J.
    Zimmer, R.
    Herz, D.
    Haupt, S.
    Zimmermann, P.
    Wachsmuth, N.
    Birnbaumer, P.
    Hofmann, P.
    Froehlich-Reiterer, E.
    Fritsch, M.
    Sternad, C. P.
    Aberer, F.
    Sourij, H.
    Moser, O.
    DIABETOLOGIA, 2023, 66 (SUPPL 1) : S412 - S413
  • [29] Comparison of total annual direct costs among Swedish residents with poorly controlled type 1 diabetes: standard care versus real-time continuous glucose monitoring
    Graham, C.
    Agardh, D. -C.
    Gerhardsson, P.
    Hankin, C. S.
    DIABETOLOGIA, 2010, 53 : S26 - S26
  • [30] Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
    Hoeks, L. B. E. A.
    Greven, W. L.
    de Valk, H. W.
    DIABETIC MEDICINE, 2011, 28 (04) : 386 - 394